Comparison of mixed refrigerant cycles for natural gas liquefaction: From single mixed refrigerant to mixed fluid cascade processes

被引:6
|
作者
Tak, Kyungjae [1 ]
Park, Jaedeuk [2 ]
Moon, Il [3 ]
Lee, Ung [1 ,4 ,5 ]
机构
[1] Korea Inst Sci & Technol, Clean Energy Res Ctr, 5 Hwarang Ro 14 Gil, Seoul 02792, South Korea
[2] Korea Res Inst Chem Technol, Proc Design & Dev Res Ctr, 141 Gajeong Ro, Daejeon 34114, South Korea
[3] Yonsei Univ, Dept Chem & Biomol Engn, 50 Yonsei Ro, Seoul 03722, South Korea
[4] Korea Univ Sci & Technol UST, KIST Sch, Div Energy & Environm Technol, Seoul 02792, South Korea
[5] Korea Univ, KU KIST Grad Sch Energy & Environm, Seoul 02841, South Korea
关键词
SMR process; Dual mixed refrigerant process; DMR process; MFC process; Liquefied natural gas; Process optimization; OPTIMIZATION; DESIGN; TEMPERATURE; SYSTEMS;
D O I
10.1016/j.energy.2023.127051
中图分类号
O414.1 [热力学];
学科分类号
摘要
Natural gas liquefaction plants have adopted mixed refrigerant (MR) cascade configurations to improve energy efficiency and process irreversibility. The MR cascade processes consist of multi-stream heat exchangers (MSHEs) and compression systems for each MR cycle. In this study, MR cascade cycles were modeled and optimized to compare and analyze the MR cascade processes. Compared to a single MR process with one MSHE, considered as the base case herein (995.0 kJ/kg LNG), a triple MR process showed 19.0% energy reduction (805.6 kJ/kg LNG). Because triple MR processes require at least three MSHEs, a single MR process with three MSHEs was also compared, which obtained only 3.9% energy reduction (956.1 kJ/kg LNG) compared to the base case. Additional process configurations, such as MR cascades with two MSHEs per MR cycle and dual MR processes, were also considered in this study. An exergy analysis of the optimized energy results revealed that the decreased exergy loss in the heat exchangers was the main factor for the energy reductions. For example, a specific work reduction of 129.5 kJ/kg LNG among 189.4 kJ/kg LNG for the triple MR process was attributed to the exergy improvement at the MSHEs and coolers.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Exergoeconomic evaluation of single mixed refrigerant natural gas liquefaction processes
    Mehrpooya, Mehdi
    Ansarinasab, Hojat
    ENERGY CONVERSION AND MANAGEMENT, 2015, 99 : 400 - 413
  • [2] Advanced exergoeconomic evaluation of single mixed refrigerant natural gas liquefaction processes
    Mehrpooya, Mehdi
    Ansarinasab, Hojat
    JOURNAL OF NATURAL GAS SCIENCE AND ENGINEERING, 2015, 26 : 782 - 791
  • [3] Influence of heavy hydrocarbons in mixed refrigerant on natural gas liquefaction processes
    Jia, Rong
    Lin, Wensheng
    Huagong Xuebao/CIESC Journal, 2015, 66 : 379 - 386
  • [4] Versatile Simulation Method for Complex Single Mixed Refrigerant Natural Gas Liquefaction Processes
    Vikse, Matias
    Watson, Harry A. J.
    Gundersen, Truls
    Barton, Paul, I
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2018, 57 (17) : 5881 - 5894
  • [5] Energy and economic comparison of five mixed-refrigerant natural gas liquefaction processes
    Pereira, Matheus A. M.
    Santos, Lucas F.
    Ravagnani, Mauro A. S. S.
    Costa, Caliane B. B.
    Caballero, Jose A.
    ENERGY CONVERSION AND MANAGEMENT, 2022, 272
  • [6] MIXED REFRIGERANT CASCADE CYCLES FOR LNG
    KINARD, GE
    GAUMER, LS
    CHEMICAL ENGINEERING PROGRESS, 1973, 69 (01) : 56 - 61
  • [7] Synthesis of mixed refrigerant cascade cycles
    Vaidyaraman, S
    Maranas, CD
    CHEMICAL ENGINEERING COMMUNICATIONS, 2002, 189 (08) : 1057 - 1078
  • [8] A new strategy for mixed refrigerant composition optimisation in the propane precooled mixed refrigerant natural gas liquefaction process
    Zhang, Shouxin
    Zou, Zimo
    Klemes, Jiri Jaromir
    Varbanov, Petar Sabev
    Shahzad, Khurram
    Ali, Arshid Mahmood
    Wang, Bo-Hong
    ENERGY, 2023, 274
  • [9] REDUCING HEAVY HYDROCARBONS IN MIXED REFRIGERANT USED IN NATURAL GAS LIQUEFACTION PROCESSES
    Jia, R.
    Song, Y.
    Lin, W.
    11TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS (2014): NATURAL REFRIGERANTS AND ENVIRONMENTAL PROTECTION, 2014, : 918 - 924
  • [10] Optimization of single mixed-refrigerant natural gas liquefaction processes described by nondifferentiable models
    Watson, Harry A. J.
    Vikse, Matias
    Gundersen, Truls
    Barton, Paul I.
    ENERGY, 2018, 150 : 860 - 876