Three-dimensional Motion Analysis of Sacroiliac Joint Mobility: A Reliability Study

被引:0
|
作者
Parchekouhi, Ahmad Bahramian [1 ]
Karimi, Noureddin [2 ]
Yousefi, Mohammad [3 ]
Ghomsheh, Farhad Tabatabai [4 ]
Rahnama, Leila [5 ]
机构
[1] Univ Social Welf & Rehabil Sci, Physiotherapy, Tehran, Iran
[2] Univ Social Welf & Rehabil Sci, Dept Physiotherapy, Tehran, Iran
[3] Univ Birjand, Fac Sport Sci, Sports Biomech, Birjand, Iran
[4] Univ Social Welf & Rehabil Sci, Pediat Neurorehabil Res, Ergon Dept, Tehran, Iran
[5] Calif State Univ Los Angeles, Sch Kinesiol, Los Angeles, CA 90032 USA
关键词
3D motion analysis; Forward flexion test; Reliability; Sacroiliac joint; MOVEMENTS; ACCURACY; VALIDITY; SYSTEM; TESTS;
D O I
10.32592/ircmj.2023.25.1.2440
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Sacroiliac joint (SIJ) movement has been investigated in many studies using a motion analysis system; however, the reliability of this method has not been well defined yet. Objectives: This study aimed to investigate the reliability of measuring the three-dimensional (3D) movement of the SIJ through the motion analysis system. Methods: A total of 10 healthy participants performed three forward flexions from a standing position twice in one session with an interval of 30 minutes. The movements were captured by the VICON motion analysis system, and the motion of the sacrum relative to each innominate was estimated in three plans of movement. The test-retest reliability was calculated with the average of three trials using the intraclass correlation coefficient (ICC) with a 95% confidence interval (CI). Results: The measurements demonstrated good to excellent reliability (ICC: from 0.61 to 0.97) that was achieved for the SIJ motion variables. Conclusion: The outcomes of this study showed that the 3D motion analysis can be used for the evaluation of SIJ mobility due to its acceptable reliability.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Intra-observer reliability in three-dimensional kinematic analysis of sacroiliac joint mobility
    da Veiga, Thiago Rebello
    da Silva, Andre Custodio
    Gomes da Silva, Rodrigo Teixeira
    Machado Carvalho, Sandro Luiz
    Orsini, Marco
    Silva, Julio Guilherme
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2015, 27 (04) : 1001 - 1004
  • [2] In vivo measurement of the three-dimensional motion of the sacroiliac joint
    Wilke, HJ
    Fischer, K
    Jeanneret, B
    Claes, L
    Magerl, F
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1997, 135 (06): : 550 - 556
  • [3] Physiological in vitro sacroiliac joint motion: a study on three-dimensional posterior pelvic ring kinematics
    Hammer, Niels
    Scholze, Mario
    Kibsgard, Thomas
    Klima, Stefan
    Schleifenbaum, Stefan
    Seidel, Thomas
    Werner, Michael
    Grunert, Ronny
    JOURNAL OF ANATOMY, 2019, 234 (03) : 346 - 358
  • [4] Three-dimensional analysis of cricoarytenoid joint motion
    Wang, RC
    LARYNGOSCOPE, 1998, 108 (04): : 1 - 17
  • [5] A new in vitro measurement technique for small three-dimensional joint motion and its application to the sacroiliac joint
    Wang, M
    Bryant, JT
    Dumas, GA
    MEDICAL ENGINEERING & PHYSICS, 1996, 18 (06) : 495 - 501
  • [6] A new in vitro measurement technique for small three-dimensional joint motion and its application to the sacroiliac joint
    Dept. of Mechanical Engineering, Queen's University, Kingston, Ont. K7L 3N6, Canada
    不详
    MED. ENG. PHYS., 6 (495-501):
  • [7] Mechanical testing for three-dimensional motion analysis reliability
    Miller, Emily
    Kaufman, Kenton
    Kingsbury, Trevor
    Wolf, Erik
    Wilken, Jason
    Wyatt, Marilynn
    GAIT & POSTURE, 2016, 50 : 116 - 119
  • [8] Degeneration of the Sacroiliac Joint in Hip Osteoarthritis Patients: A Three-Dimensional Image Analysis
    Asada, Maki
    Tokunaga, Daisaku
    Arai, Yuji
    Oda, Ryo
    Fujiwara, Hiroyoshi
    Yamada, Kei
    Kubo, Toshikazu
    JOURNAL OF THE BELGIAN SOCIETY OF RADIOLOGY, 2019, 103 (01):
  • [9] The initiation and sequence of digital joint motion - A three-dimensional motion analysis
    Somia, N
    Rash, GS
    Wachowiak, M
    Gupta, A
    JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1998, 23B (06): : 792 - 795
  • [10] Error analysis of a system for measuring three-dimensional joint motion
    Suntay, W.J.
    Grood, E.S.
    Hefzy, M.S.
    Journal of Biomechanical Engineering, 1983, 105 (02) : 127 - 135