Simplified image-based dosimetry using planar images and patient-specific S-values

被引:0
|
作者
Kim, Keon Min [1 ,2 ]
Suh, Minseok [3 ,4 ]
Cheon, Gi Jeong [3 ,4 ]
Lee, Min Sun [5 ,7 ]
Lee, Jae Sung [1 ,2 ,3 ,4 ,6 ]
机构
[1] Seoul Natl Univ, Grad Sch, Interdisciplinary Program Bioengn, Seoul, South Korea
[2] Seoul Natl Univ, Grad Sch, Integrated Major Innovat Med Sci, Seoul, South Korea
[3] Seoul Natl Univ, Coll Med, Dept Nucl Med, Seoul, South Korea
[4] Seoul Natl Univ, Inst Radiat Med, Med Res Ctr, Seoul, South Korea
[5] Korea Atom Energy Res Inst, Daejeon, South Korea
[6] Seoul Natl Univ, Coll Med, Dept Nucl Med, 103 Daehak Ro, Seoul 03080, South Korea
[7] Korea Atom Energy Res Inst, Nucl Emergency & Environm Protect Div, Environm Radioact Assessment Team, Daejeon 34057, South Korea
基金
新加坡国家研究基金会;
关键词
hybrid dosimetry; Monte Carlo simulation; planar image; radiation dosimetry; radionuclide therapy; SPECT; THERAPY;
D O I
10.1002/mp.16974
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Single time point measurement approach and hybrid dosimetry were proposed to simplify the dosimetry process. It is anticipated that utilizing patient-specific S-value would enable more accurate dosimetry assessment based on imaging compared to using the conventional MIRD S-values. Purpose: We performed planar image-based dosimetry scaled with a single SPECT image for the entire treatment cycle using patient-specific S-values (PSS dosimetry) of organs. PSS dosimetry could further simplify the dosimetry procedure compared with a conventional 2D planar/3D SPECT hybrid dosimetry, as PSS dosimetry requires only one SPECT/CT image for the treatment of the entire cycle, whereas the conventional hybrid dosimetry requires a SPECT/CT image for each treatment cycle. Methods: 177Lu-DOTATATE SPECT/CT and planar image datasets acquired from Seoul National University Hospital (SNUH, Seoul, Republic of Korea) were utilized for the evaluation. Images were acquired 4, 24, 48, and 120 h after patients' intravenous injection of 177Lu-DOTATATE. Dose estimations based on a Monte Carlo (MC) simulation using the Geant4 Application for Emission Tomography (GATE) (v.8.2) were considered as the reference. Planar image-based dosimetry scaled with a single SPECT image was performed using the patient-specific S-value (PSS). Briefly, the CT image was considered as the patient's anatomical reference and PSSs were quantified using the multiple voxel S-value (VSV) method. Then, PSS dosimetry was performed by obtaining activity information from sequential planar images and a scaling factor derived from a single SPECT/planar image pair. Hybrid dosimetry using sequential planar images and a single SPECT image was performed for comparison. The absorbed doses of the kidneys, bone marrow (BM) in the lumbar spine, liver, and spleen calculated using the PSS and hybrid dosimetries were compared with the reference MC results. Results: The mean differences (MDs) of the self-absorption S-values between S-value of OLINDA/EXM and PSS for the kidneys, liver, and spleen were -0.04%, -2.39%, and -2.62%, respectively. However, the differences in the self-absorption S-values were significantly higher for the BM (84.99%) and the remainder of the body (ROB) (280.84%). The absorbed doses estimated by the PSS and hybrid dosimetries showed relatively high errors compared with MC simulation result, regardless of the organ. In contrast, the PSS and hybrid dosimetries produced similar dose estimates. For the entire cycles of the treatment, the MDs of absorbed doses between PSS and hybrid dosimetries were -3.31%, -6.04%, 3.37%, and -2.17% for the kidneys, BM, liver, and spleen, respectively. Through a correlation analysis and the Wilcoxon signed-rank test, we concluded that there was no significant difference between the results obtained by the two dosimetry methods. Conclusions: As the PSS was derived using CT images with actual anatomical information and organ-specific volume of interest (VOI), PSS dosimetry provided reliable results. PSS dosimetry was robust in estimating the absorbed dose for the later treatment cycles. Therefore, PSS dosimetry outperformed hybrid dosimetry in terms of dose estimation for a greater number of treatment cycles.
引用
收藏
页码:5708 / 5721
页数:14
相关论文
共 50 条
  • [1] USE OF PATIENT-SPECIFIC KINETICS AND S-VALUES IN RADIOIMMUNOTHERAPY DOSIMETRY
    ECKERMAN, KF
    RYMAN, JC
    WATSON, EE
    STABIN, MG
    JOURNAL OF NUCLEAR MEDICINE, 1988, 29 (12) : 2030 - 2031
  • [2] Patient-specific scaling of reference S-values for cross-organ radionuclide S-values:: What is appropriate?
    Petoussi-Henss, Nina
    Bolch, W. E.
    Zankl, M.
    Sgouros, G.
    Wessels, B.
    RADIATION PROTECTION DOSIMETRY, 2007, 127 (1-4) : 192 - 196
  • [3] An image-based modeling framework for patient-specific computational hemodynamics
    Antiga, Luca
    Piccinelli, Marina
    Botti, Lorenzo
    Ene-Iordache, Bogdan
    Remuzzi, Andrea
    Steinman, David A.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2008, 46 (11) : 1097 - 1112
  • [4] An image-based modeling framework for patient-specific computational hemodynamics
    Luca Antiga
    Marina Piccinelli
    Lorenzo Botti
    Bogdan Ene-Iordache
    Andrea Remuzzi
    David A. Steinman
    Medical & Biological Engineering & Computing, 2008, 46
  • [5] Cerebral Aneurysms: A Patient-Specific and Image-Based Management Pipeline
    Villa-Uriol, M. C.
    Larrabide, I.
    Pozo, J. M.
    Kim, M.
    De Craene, M.
    Camara, O.
    Zhang, C.
    Geers, A. J.
    Bogunovic, H.
    Morales, H.
    Frangi, A. F.
    COMPUTATIONAL VISION AND MEDICAL IMAGE PROCESSING: RECENT TRENDS, 2011, 19 : 327 - 349
  • [6] Development of Image-Based Patient-Specific Dosimetry Technique for Internal Radiotherapy (IRT) for Neuroendocrine Tumours: A Preliminary Report
    Birkenfeld, B.
    Listewnik, M. H.
    Zorga, P.
    Piwowarska-Bilska, H.
    Grimes, J.
    Shcherbinin, S.
    Celler, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S429 - S429
  • [7] Comparison of Voxel S-values and Monte Carlo Simulation in [177Lu]Lu-DOTA-TATE Quantification for Patient-Specific Dosimetry
    Rodrigues, C.
    Ferreira, P.
    Oliveira, F. P. M.
    Silva, A.
    Peralta, L.
    Costa, C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (SUPPL 1) : S75 - S75
  • [8] Planar EPID-Based Dosimetry for SRS and SRT Patient-Specific QA
    Thongsawad, Sangutid
    Chanton, Tadchapong
    Saiyo, Nipon
    Udee, Nuntawat
    LIFE-BASEL, 2021, 11 (11):
  • [9] Image-based biomarkers for engineering neuroblastoma patient-specific computational models
    Hervas-Raluy, Silvia
    Sainz-DeMena, Diego
    Gomez-Benito, Maria Jose
    Garcia-Aznar, Jose Manuel
    ENGINEERING WITH COMPUTERS, 2024, 40 (05) : 3215 - 3231
  • [10] Image-Based Estimation of Ventricular Fiber Orientations for Patient-Specific Simulations
    Vadakkumpadan, Fijoy
    Arevalo, Hermenegild
    Ceritoglu, Can
    Miller, Michael
    Trayanova, Natalia
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 1672 - 1675