Prototype for rapid test devices to detect residues of sulfonamides in chicken carcasses from traditional breeders in Surabaya, Indonesia

被引:0
|
作者
Lazuardi, Mochamad [1 ]
Hestianah, Eka Pramyrtha [2 ]
Restiadi, Tjuk Imam [3 ]
机构
[1] Univ Airlangga, Fac Vet Med, Subdiv Vet Pharm, Mulyorejo Rd, Surabaya 60115, Indonesia
[2] Univ Airlangga, Fac Vet Med, Div Histol, Mulyorejo Rd, Surabaya 60115, Indonesia
[3] Univ Airlangga, Fac Vet Med, Div Reprod, Mulyorejo Rd, Surabaya 60115, Indonesia
关键词
diazotation; food safety; residues; sulfadiazine; veterinary drugs; SAMPLES;
D O I
10.14202/vetworld.2023.1252-1259
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Background and Aim: Sulfadiazine, one of the sulfonamide group's active compounds, is widely used for therapeutic production against several diseases. Veterinary drug residues can have a significant impact on human health conditions. This study aimed to develop a prototype of rapid test devices (RTDs) for detecting sulfadiazine residues on chicken carcasses based on the color indication. Materials and Methods: Seven samples of carcasses collected from traditional breeders in Surabaya-Indonesia were prepared and tested using RTDs. This sample represents the population considering that in the last report, the use of antibiotics was more than 40%, while the ability to monitor RTDs was estimated at 100. The standard color of purple by Hex code standard color or decimal code color was used to compare the positive samples. A light-emitting diode (LED) lamp was used to observe purple color. Analysis of sulfonamides resulting from RTDs was compared using a ultraviolet -visible spectrophotometer. Results: Sulfonamides contamination levels of 50% and 100% were detected at concentrations of 0.472 mu g/mL and 0.642 mu g/mL, respectively. Sulfonamides contamination that was <0.395 mu g/mL did not appear purple. Conclusion: The study's findings showed that RTDs can be used to detect sulfonamides residues at a limit of detection 0.5 mu g/mL after a 45 min exposure to an LED operating at a wavelength of 980 nm (p < 0.05). The limitation of RTDs was not being able to monitor the presence of residues bound in fat samples. Rapid test devices can be developed for commonly monitoring devices due to the limited technology available in the market.
引用
收藏
页码:1252 / 1259
页数:8
相关论文
共 3 条
  • [1] Designing prototype rapid test device at qualitative performance to detect residue of tetracycline in chicken carcass
    Lazuardi, Mochamad
    Hestianah, Eka Pramyrtha
    Restiadi, Tjuk Imam
    [J]. VETERINARY WORLD, 2022, 15 (04) : 1058 - 1065
  • [2] Prevalence of Antibiotic-resistance Enterobacteriaceae strains Isolated from Chicken Meat at Traditional Markets in Surabaya, Indonesia
    Yulistiani, R.
    Praseptiangga, D.
    Supyani
    Sudibya
    Raharjo, D.
    Shirakawa, T.
    [J]. INTERNATIONAL CONFERENCE ON FOOD SCIENCE AND ENGINEERING 2016, 2017, 193
  • [3] Occurrences of Salmonella spp. and Escherichia coli in chicken meat, intestinal contents and rinse water at slaughtering place from traditional market in Surabaya, Indonesia
    Yulistiani, R.
    Praseptiangga, D.
    Supyani
    Sudibya
    [J]. INTERNATIONAL CONFERENCE ON FOOD SCIENCE AND ENGINEERING, 2019, 633