Effect of cross-polarization filters on the trueness of colors obtained with a single-lens reflex camera, macro lens, and a ring flash

被引:4
|
作者
Yilmaz, Burak [1 ,2 ,3 ]
Dede, Dogu Omur [4 ]
Diker, Emre [5 ]
Fonseca, Manrique [1 ]
Johnston, William Michael [3 ]
Kucukekenci, Ahmet Serkan [4 ]
机构
[1] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland
[2] Univ Bern, Sch Dent Med, Dept Restorat Prevent & Pediat Dent, Bern, Switzerland
[3] Ohio State Univ, Div Restorat & Prosthet Dent, Coll Dent, Columbus, OH USA
[4] Ordu Univ, Fac Dent, Dept Prosthodont, Ordu, Turkiye
[5] Ankara Univ, Fac Dent, Dept Prosthodont, Ankara, Turkiye
关键词
color difference; color matching; cross-polarizing filter; digital image; spectroradiometer; DENTAL PHOTOGRAPHY; SHADE; DIFFERENCE;
D O I
10.1111/jerd.13053
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ObjectiveTo investigate the effect of cross-polarization filters on the colors of shade tabs obtained with a digital single-lens reflex (DSLR) camera, macrolens, and a ring flash. Materials and MethodsDigital images of four shade tables (1M1, 3L2.5, 3R2.5, and 5M3) from the VITA Toothguide 3D-Master shade guide were taken using a DSLR camera, 100 mm macrolens, and ring flash with two different cross-polarizing filters (Polar_eyes and Filtropolar), and without (Nonpolarizer; n = 7). The CIE L*a*b* color coordinates of digital images were calculated and remeasured with a spectroradiometer (SR). The color differences (Delta E-00) between the SR and digital images were calculated and analyzed with the two-way analysis of variance (ANOVA) and Tukey HSD test (alpha = 0.05). Results Delta E-00 values of all test groups were higher than the clinically acceptable threshold ( increment E-00 > 1.80). While the increment E-00 values of Filtropolar (6.19 +/- 0.44) and Polar_eyes (7.82 +/- 0.23) groups were significantly higher than the Nonpolarizer (4.69 +/- 0.32) for the 1M1 shade tab, increment E-00 value of Polar_eyes (6.23 +/- 0.34) was significantly lower than Nonpolarizer (10.71 +/- 0.48) group for 5M3 shade tab (p < 0.05). ConclusionThe color-matching results of tested digital photography techniques with and without cross-polarization were unacceptable, compared to a spectroradiometer. While digital photography with Polar_eyes cross-polarizing filter has closer results to the reference device for the low-in-value shade table (5M3), for the high-in-value shade table (1M1), improved results were obtained without a cross-polarizing filter. Clinical SignificanceThe cross-polarization filters are increasingly used in dentistry for tooth color communication with digital photography techniques. However, the digital photography techniques with-without cross-polarization filterers should be improved to obtain clinically acceptable color-matching results.
引用
收藏
页码:878 / 885
页数:8
相关论文
共 9 条
  • [1] SINGLE-LENS REFLEX CAMERA WITH MINIATURE BEARINGS
    HOERNER, H
    ROSSELET, J
    [J]. BALL BEARING JOURNAL, 1974, (181): : 12 - 14
  • [2] DR with a DSLR: Digital Radiography with a Digital Single-Lens Reflex camera
    Fan, Helen
    Durko, Heather L.
    Moore, Stephen K.
    Moore, Jared
    Miller, Brian W.
    Furenlid, Lars R.
    Pradhan, Sunil
    Barrett, Harrison H.
    [J]. MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [3] Comparison of the colour accuracy of a single-lens reflex camera and a smartphone camera in a clinical context
    Yung, Denise
    Tse, Andy K. L.
    Hsung, Richard T. C.
    Botelho, Michael G.
    Pow, Edmond H. N.
    Lam, Walter Y. H.
    [J]. JOURNAL OF DENTISTRY, 2023, 137
  • [4] Acquisition of chemiluminescent signals from immunoblots with a digital single-lens reflex camera
    Khoury, Mitri K.
    Parker, Ian
    Aswad, Dana W.
    [J]. ANALYTICAL BIOCHEMISTRY, 2010, 397 (01) : 129 - 131
  • [5] Technology Forecasting of Digital Single-Lens Reflex Camera Market: The Impact of Segmentation in TFDEA
    Yoon, Byung Sung
    Charoensupyan, Apisit
    Hu, Nan
    Koosawangsri, Rachanida
    Abdulai, Mimie
    Wang, Xiaowen
    [J]. 2013 PROCEEDINGS OF TECHNOLOGY MANAGEMENT IN THE IT-DRIVEN SERVICES (PICMET'13), 2013, : 2116 - 2129
  • [6] Development of 36M-Pixel Micro-CT Using Digital Single-Lens Reflex Camera
    Umetani, Keiji
    Kawata, Yoshiki
    Niki, Noboru
    Itoh, Harumi
    [J]. 2015 IEEE INTERNATIONAL CONFERENCE ON IMAGING SYSTEMS AND TECHNIQUES (IST) PROCEEDINGS, 2015, : 11 - 15
  • [7] A SHAPED SINGLE REFLECTOR OFFSET ANTENNA WITH LOW CROSS-POLARIZATION FED BY A LENS HORN
    LIER, E
    SKYTTEMYR, SA
    [J]. IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 1994, 42 (04) : 478 - 483
  • [8] High-throughput measurement of coefficient of thermal expansion using a high-resolution digital single-lens reflex camera and digital image correlation
    Li, Chenzhuo
    Luo, Haojian
    Pan, Bing
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (10):
  • [9] Comparison of indocyanine green and sodium fluorescein for anterior segment angiography of ophthalmically normal eyes of goats, sheep, and alpacas performed with a digital single-lens reflex camera adaptor
    LoPinto, Alexander J.
    Pirie, Chris G.
    Ayres, Sandra L.
    Bedenice, Daniela
    [J]. AMERICAN JOURNAL OF VETERINARY RESEARCH, 2017, 78 (03) : 311 - 320