Linear Boltzmann equation solver for voxel-level dosimetry in radiopharmaceutical therapy: Comparison with Monte Carlo and kernel convolution

被引:1
|
作者
Kayal, Gunjan [1 ]
Van, Benjamin [1 ]
Andl, George [2 ]
Tu, Cheng [2 ]
Wareing, Todd [2 ]
Wilderman, Scott [1 ]
Mikell, Justin [3 ,4 ]
Dewaraja, Yuni K. [1 ,5 ]
机构
[1] Univ Michigan, Dept Radiol, Ann Arbor, MI USA
[2] Varian Med Syst, Atlanta, GA USA
[3] Washington Univ St Louis, Dept Radiat Oncol, St Louis, MO USA
[4] Univ Michigan, Dept Radiat Oncol, Ann Arbor, MI USA
[5] Univ Michigan Med, Dept Radiol, 6428B Med Sci,1301 Catherine St, Ann Arbor, MI 48109 USA
关键词
dosimetry; Iodine-131; LBTE solver; Lutetium-177; radiopharmaceutical therapy; theranostics; Yttrium-90; EXPERIMENTAL VALIDATION; TRANSPORT-EQUATION; DOSE CALCULATIONS; ELECTRON-BEAMS; CODE; RADIOTHERAPY; DPM; PHOTON; SPECT; MODEL;
D O I
10.1002/mp.16996
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: With recent interest in patient-specific dosimetry for radiopharmaceutical therapy (RPT) and selective internal radiation therapy (SIRT), an increasing number of voxel-based algorithms are being evaluated. Monte Carlo (MC) radiation transport, generally considered to be the most accurate among different methods for voxel-level absorbed dose estimation, can be computationally inefficient for routine clinical use. Purpose: This work demonstrates a recently implemented grid-based linear Boltzmann transport equation (LBTE) solver for fast and accurate voxel-based dosimetry in RPT and SIRT and benchmarks it against MC. Methods: A deterministic LBTE solver (Acuros MRT) was implemented within a commercial RPT dosimetry package (Velocity 4.1). The LBTE is directly discretized using an adaptive mesh refined grid and then the coupled photon-electron radiation transport is iteratively solved inside specified volumes to estimate radiation doses from both photons and charged particles in heterogeneous media. To evaluate the performance of the LBTE solver for RPT and SIRT applications, Lu-177 SPECT/CT, Y-90 PET/CT, and I-131 SPECT/CT images of phantoms and patients were used. Multiple lesions (2-1052 mL) and normal organs were delineated for each study. Voxel dosimetry was performed with the LBTE solver, dose voxel kernel (DVK) convolution with density correction, and a validated in-house MC code using the same time-integrated activity and density maps as input to the different dose engines. The resulting dose maps, difference maps, and dose-volume-histogram (DVH) metrics were compared, to assess the voxel-level agreement. Evaluation of mean absorbed dose included comparison with structure-level estimates from OLINDA. Results: In the phantom inserts/compartments, the LBTE solver versus MC and DVK convolution demonstrated good agreement with mean absorbed dose and DVH metrics agreeing to within 5% except for the D90 and D70 metrics of a very low activity concentration insert of 90Y where the agreement was within 15%. In the patient studies (five patients imaged after Lu-177 DOTATATE RPT, five after Y-90 SIRT, and two after I-131 radioimmunotherapy), in general, there was better agreement between the LBTE solver and MC than between LBTE solver and DVK convolution for mean absorbed dose and voxel-level evaluations. Across all patients for all three radionuclides, for soft tissue structures (kidney, liver, lesions), the mean absorbed dose estimates from the LBTE solver were in good agreement with those from MC (median difference < 1%, maximum 9%) and those from DVK (median difference < 5%, maximum 9%). The LBTE and OLINDA estimates for mean absorbed dose in kidneys and liver agreed to within 10%, but differences for lesions were larger with a maximum 14% for Lu-177, 23% for Y-90, and 26% for I-131. For bone regions, the agreement in mean absorbed doses between LBTE and both MC and DVK were similar (median < 11%, max 11%) while for lung the agreement between LBTE and MC (median < 1%, max 8%) was substantially better than between LBTE and DVK (median < 16%, max 33%). Voxel level estimates for soft tissue structures also showed good agreement between the LBTE solver and both MC and DVK with a median difference < 5% (maximum < 13%) for the DVH metrics with all three radionuclides. The largest difference in DVH metrics was for the D90 and D70 metric in lung and bone where the uptake was low. Here, the difference between LBTE and MC had a median value < 14% (maximum 23%) for bone and < 4% (maximum 37%) for lung, while the corresponding differences between LBTE and DVK were < 23% (maximum 31%) and < 67% (maximum 313%), respectively. For a typical patient with a matrix size of 166 x 166 x 129 (voxel size 3 x 3 x 3 mm3), voxel dosimetry using the LBTE solver was as fast as similar to 2 min on a desktop computer. Conclusion: Having established good agreement between the LBTE solver and MC for RPT and SIRT applications, the LBTE solver is a viable option for voxel dosimetry that can be faster than MC. Further analysis is being performed to encompass the broad range of radionuclides and conditions encountered clinically.
引用
收藏
页码:5604 / 5617
页数:14
相关论文
共 13 条
  • [1] Toward Individualized Voxel-Level Dosimetry for Radiopharmaceutical Therapy
    Xiao, Ying
    Roncali, Emilie
    Hobbs, Robert
    St James, Sara
    Bednarz, Bryan
    Benedict, Stanley
    Dewaraja, Yuni K.
    Frey, Eric
    Grudzinski, Joseph
    Sgouros, George
    Buchsbaum, Jeffrey C.
    Capala, Jacek
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2021, 109 (04): : 902 - 904
  • [2] A new option for fast and accurate voxel-level dosimetry in radiopharmaceutical therapy with a grid-based linear Boltzmann dose transport solver
    Van, B.
    Mikell, J. K.
    Andl, G.
    Dewaraja, Y. K.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S396 - S396
  • [3] Voxel-level dosimetry with a grid-based Boltzmann solver for patient-specific nuclear medicine dosimetry
    Mikell, J.
    Mourtada, F.
    Wareing, T.
    Kappadath, S. C.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S49 - S50
  • [4] Combining Monte Carlo Voxel-Level External Beam Radiotherapy and Iodine-131 SPECT Based Radiopharmaceutical Therapy Dosimetry Using Deformable Registration and Radiobiological Quantities
    Adam, D.
    Grudzinski, J.
    Hill, P.
    Bradshaw, T.
    Cho, S.
    Burr, A.
    Harari, P.
    Bednarz, B.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E309 - E310
  • [5] Voxel-Level Dosimetry for Combined Iodine 131 Radiopharmaceutical Therapy and External Beam Radiation Therapy Treatment Paradigms for Head and Neck Cancer
    Adam, David P.
    Grudzinski, Joseph J.
    Marsh, Ian R.
    Hill, Patrick M.
    Cho, Steve Y.
    Bradshaw, Tyler J.
    Longcor, Jarrod
    Burr, Adam
    Bruce, Justine Y.
    Harari, Paul M.
    Bednarz, Bryan P.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2024, 119 (04): : 1275 - 1284
  • [6] GPU-Accelerated Full Monte Carlo Affords Accurate Voxel-Based Dosimetry for Radiopharmaceutical Therapy
    Grudzinski, Joseph
    Bednarz, Bryan
    Wickre, Paul
    Stearns, Charles
    Culberson, Wes
    Bertinetti, Andrew
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [7] Canine Anatomic Voxel Phantom for Internal Dosimetry: Comparison between Monte-Carlo and Convolution Method
    Moreau, M.
    Govignon, A.
    Mauxion, T.
    Fusellier, M.
    Abadie, J.
    Bardies, M.
    Hindorf, C.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S318 - S318
  • [8] An Unsplit Monte-Carlo solver for the resolution of the linear Boltzmann equation coupled to (stiff) Bateman equations
    Bernede, Adrien
    Poette, Gael
    [J]. JOURNAL OF COMPUTATIONAL PHYSICS, 2018, 354 : 211 - 241
  • [9] Study of the Impact of Tissue Density Heterogeneities on 3-Dimensional Abdominal Dosimetry: Comparison Between Dose Kernel Convolution and Direct Monte Carlo Methods
    Dieudonne, Arnaud
    Hobbs, Robert F.
    Lebtahi, Rachida
    Maurel, Fabien
    Baechler, Sebastien
    Wahl, Richard L.
    Boubaker, Ariane
    Le Guludec, Dominique
    Sgouros, Georges
    Gardin, Isabelle
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2013, 54 (02) : 236 - 243
  • [10] Deterministic linear Boltzmann transport equation solver for patient-specific CT dose estimation: Comparison against a Monte Carlo benchmark for five realistic scanner configurations and patient models
    Principi, Sara
    Wang, Adam
    Maslowski, Alexander
    Wareing, Todd
    Jordan, Petr
    Schmidt, Taly Gilat
    [J]. MEDICAL PHYSICS, 2020, 47 (12) : 6470 - 6483