Liquid water content measurement with SEA multi-element sensor in CARDC icing wind tunnel: Calibration and performance

被引:5
|
作者
Guo, Xiangdong [1 ,2 ]
Wang, Zixu [2 ]
Zhao, Rong [2 ]
Wu, Yingchun [1 ]
Wu, Xuecheng [2 ]
Yi, Xian [2 ]
机构
[1] Zhejiang Univ, State Key Lab Clean Energy Utilizat, Hangzhou 310027, Peoples R China
[2] China Aerodynam Res & Dev Ctr, Key Lab Icing & Anti Deicing, Mianyang, Peoples R China
基金
中国国家自然科学基金;
关键词
Cloud liquid water content; Multi-element sensor; Icing wind tunnel; Calibration and performance; Dry and wet power calculation method; Droplet retention efficiency; Accuracy validation; PROBE; ICE;
D O I
10.1016/j.applthermaleng.2023.121255
中图分类号
O414.1 [热力学];
学科分类号
摘要
The measurement of cloud liquid water content (LWC) plays a critical role in the development of icing airworthiness standards for aircraft and the calibration of icing wind tunnels. The SEA multi-element sensor, the modern hot-wire device for LWC measurement, still faces several challenges for performance calibration due to the effects of the baseline drift and droplet retention characteristics. To fully calibrate the performance of the sensor, two wind tunnel tests were conducted in the China Aerodynamics Research and Development Center (CARDC) icing wind tunnel including a dry air calibration test and an icing cloud measurement test. Using the in-situ dry power calibration method developed in this study, the compensation function and the empirical formula of dry air Nusselt number for each sense element are obtained, and present great linear characteristics in the range of the test section velocity ������TS from 40 to 110 m/s. However, there is an abnormal peak area of total power for the W1 element at the ������TS of 120 and 130 m/s, which may be associated with significant water vapor condensation. The consistency and discrepancy of four LWC calculation methods via the combinations of dry and wet power calculation methods are assessed. Further, the LWC response characteristics of the sense elements are examined and the correlations of the droplet retention efficiency for the W2 and W3 elements are acquired as functions of median volume diameter. Finally, the measurement accuracy of the SEA multi-element sensor is validated compared to the icing blade device. It demonstrates that the uncertainty of the W1 element for the sensor is about & PLUSMN;5% at the low LWC and the W1 element has a better ability in the measurement of the high LWC.
引用
收藏
页数:12
相关论文
共 4 条
  • [1] Single and Multi-element Airfoil Performance Simulation Study and Wind Tunnel Validation
    Eisele, O.
    Pechlivanoglou, G.
    [J]. WIND ENERGY - IMPACT OF TURBULENCE, 2014, 2 : 17 - 22
  • [2] A numerical simulation of the distribution and the variation law of the liquid water content in icing wind tunnel
    Ma, Lisheng
    Song, He
    Chen, Yan
    Deng, Huanyu
    Li, Xiaofeng
    [J]. APPLIED THERMAL ENGINEERING, 2024, 236
  • [3] Photoacoustic hygrometer for icing wind tunnel water content measurement: design, analysis, and intercomparison
    Lang, Benjamin
    Breitfuss, Wolfgang
    Schweighart, Simon
    Breitegger, Philipp
    Pervier, Hugo
    Tramposch, Andreas
    Klug, Andreas
    Hassler, Wolfgang
    Bergmann, Alexander
    [J]. ATMOSPHERIC MEASUREMENT TECHNIQUES, 2021, 14 (03) : 2477 - 2500
  • [4] An investigation of the performance characteristics and operational lifetimes of multi-element thick film sensor arrays used in the determination of water quality parameters
    Atkinson, JK
    Cranny, AWJ
    Glasspool, WV
    Mihell, JA
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1999, 54 (03) : 215 - 231