Test-Retest Reliability of Local Tissue Water and Circumference Measurements in the Head and Neck Area of Healthy Women and Men

被引:1
|
作者
Hagren, Agneta [10 ,1 ,2 ]
Brogardh, Christina [1 ,3 ]
Johansson, Karin [1 ]
Sjovall, Johanna [2 ,4 ]
Ekvall Hansson, Eva [1 ,2 ]
机构
[1] Lund Univ, Dept Hlth Sci, Lund, Sweden
[2] Skane Univ Hosp, Dept Otorhinolaryngol Head & Neck Surg, Lund, Sweden
[3] Skane Univ Hosp, Dept Neurol Rehabil Med Memory Disorders & Geriat, Lund, Sweden
[4] Lund Univ, Dept Clin Sci, Lund, Sweden
关键词
head and neck cancer; reproducibility of results; lymphedema; healthy volunteers; LYMPHEDEMA; CANCER;
D O I
10.1089/lrb.2022.0081
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: Measurements of local tissue water and circumferences are methods to evaluate lymphedema. Knowledge about reference values and reproducibility needs, however, to be determined for the head and neck (HN) area of healthy persons before it can be used in persons with HN lymphedema. The objective of this study was to evaluate the test-retest reliability including measurement errors of local tissue water and neck circumference measurements (CM) in the HN area in a healthy cohort.Methods and Results: Thirty-one women and 29 men were measured on 2 occasions, 14 days apart. The percentage of tissue water content (PWC) were calculated in four facial points and neck CM at three levels. Intraclass correlation coefficient (ICC), changes in mean, standard error of measurement (SEM%), and smallest real difference (SRD%) were calculated. Reliability for PWC was fair to excellent for both women (ICC 0.67-0.89) and men (ICC 0.71-0.87). Measurement errors were acceptable in all points in both women (SEM% 3.6%-6.4%, SRD% 9.9%-17.7%) and men (SEM% 5.1%-10.9%, SRD% 14.2%-30.3%). For the CM, ICCs were excellent both for women (ICC 0.85-0.90) and men (ICC 0.92-0.94), and measurement errors were low (SEM% for women 1.9%-2.1%, SRD% 5.1%-5.9%; SEM% for men 1.6%-2.0%, SRD% 4.6%-5.6%). Most of the lowest values were found close to bone and vessels.Conclusion: Measurements for PWC and CM in the HN area are reliable in healthy women and men, with acceptable to low measurement errors. PWC points close to bony structures and vessels should, however, be used with caution.
引用
收藏
页码:381 / 387
页数:7
相关论文
共 39 条
  • [1] Test-Retest Reliability of a Protocol for Assessment of Local Tissue Water in the Head and Neck Area
    Arends, Coralie R.
    van der Molen, Lisette
    van den Brekel, Michiel W. M.
    Stuiver, Martijn M.
    LYMPHATIC RESEARCH AND BIOLOGY, 2023, : 12 - 19
  • [2] Test-Retest Reliability of Volume and Local Tissue Water Measurements in Lower Limbs of Healthy Women and Men
    Jonsson, Charlotta
    Bjurberg, Maria
    Brogardh, Christina
    Johansson, Karin
    LYMPHATIC RESEARCH AND BIOLOGY, 2020, 18 (03) : 261 - 269
  • [3] An evaluation of the test-retest reliability of the functional head impulse test in healthy young adults
    Kirazli, Gulce
    Emekci, Tugba
    Inceoglu, Feyza
    Akmese, Pelin Pistav
    Celebisoy, Nese
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2023, 280 (12) : 5339 - 5343
  • [4] Test-Retest Reliability of Video Head Impulse Test in Healthy Individuals and Individuals with Dizziness
    Singh, Niraj Kumar
    Govindaswamy, Rajeshwari
    Jagadish, Nirmala
    JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2019, 30 (09) : 744 - 752
  • [5] Test-retest reliability of electrical impedance myography in hamstrings of healthy young men
    Honorato, Renee de Caldas
    Marreiros Ferraz, Alex Soares
    Kassiano, Witalo
    Carvalho, Denise Pires
    Ceccatto, Vania Marilande
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2021, 56
  • [6] Intraurethral Sonography and the test-retest reliability of urethral sphincter measurements in women
    Heit, M
    JOURNAL OF CLINICAL ULTRASOUND, 2002, 30 (06) : 349 - 355
  • [7] Test-retest reliability of suppression head impulse paradigm (SHIMP) in healthy individuals
    Nagarajan, Aishwarya
    Ghimire, Shashish
    Elizabeth, Varsha Sam
    Sinha, Sujeet Kumar
    HEARING BALANCE AND COMMUNICATION, 2023, 21 (04) : 312 - 317
  • [8] Test-retest reliability of pressure pain threshold measurements of the upper limb and torso in young healthy women
    Jones, David H.
    Kilgour, Robert D.
    Comtoist, Alain S.
    JOURNAL OF PAIN, 2007, 8 (08): : 650 - 656
  • [9] Test-Retest reliability of the internal shoulder rotator muscles' stretch reflex in healthy men
    Heinke, Lars N.
    Knicker, Axel J.
    Albracht, Kirsten
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2022, 62
  • [10] Test-retest reliability of sudden ankle inversion measurements in subjects with healthy ankle joints
    Eechaute, Christophe
    Vaes, Peter
    Duquet, William
    Van Gheluwe, Bart
    JOURNAL OF ATHLETIC TRAINING, 2007, 42 (01) : 60 - 65