Efficacious elimination of salts from a convoluted ethylene glycol-water solution employing nanofiltration membranes

被引:0
|
作者
Mehta, Jigesh [1 ,7 ]
Panwar, D. S. [1 ]
Kohli, Deepak [1 ]
Tudu, Balraj [1 ]
Shah, Vishal [1 ]
Patel, Jigna [1 ]
Panchal, Hitesh [2 ]
Oza, Ankit D. [3 ]
Bhole, Kiran [4 ]
Gupta, Naveen Kumar [5 ]
Prakash, Chander [6 ]
机构
[1] PP Savani Univ, Dept Chem Engn, Surat, India
[2] Govt Engn Coll Patan, Dept Mech Engn, Patan, India
[3] Parul Univ, Dept Mech Engn, Vadodara, Gujarat, India
[4] Sardar Patel Coll Engn, Dept Mech Engn, Mumbai, India
[5] GLA Univ, Dept Mech Engn, Mathura, India
[6] Lovely Profess Univ, Dept Mech Engn, Phagwara, India
[7] PP Savani Univ, Dept Chem Engn, GIDC, B-86,Near Ganesh Pk Soc,500 Quarters Rd, Bharuch 393002, India
关键词
Ethylene glycol solution; dilution factor; concentration polarization; chemical cleaning; nanofiltration; WASTE-WATER; SEPARATION; ULTRAFILTRATION; STABILITY; TRANSPORT; REMOVAL; METALS; REUSE; IONS;
D O I
10.1080/15567036.2023.2259835
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In the current scientific studies, a flat-sheet module pilot plant with an HPP-200 nanofiltration membrane was employed to process an ethylene glycol-water mixture from Jayshree Chemicals, Ankleshwar, India, that contained a significant amount of sodium sulfate. The membrane clogged due to degradation fueled by the excessive salt concentration. Hence, the solution was treated because it was diminished, and the impact of dilution was investigated. Consequently, fouling occurs due to increased flux and reduced concentration polarization. 294, 490, and 784 Kpa pressures were applied to the solution. With the dilution factor, the flow rises while the rejection decreases. Rejection rates range from 97% for membrane plugging without dilution to 92% for five folds and 85% for ten folds dilution. The efficacy of chemical cleaning was investigated using 2% solutions of citric acid and ethylenediamine tetra acetic acid (EDTA). Fourier-transform infrared (FTIR) spectroscopy analysis revealed alterations in membrane structure resulting from interactions with the sodium sulfate feed solution. Scanning Electron microscope (SEM) analysis showed substantial fouling on the membrane surface, which was successfully eliminated through chemical cleaning process. The implementation of dilution and pressure control strategies demonstrated efficacy in the mitigation of fouling phenomena and the enhancement of membrane performance. The efficacy of EDTA in flux recovery (69.84%) was superior to that of citric acid (55.77%) during chemical cleaning processes. These findings have potential to facilitate the implementation of nanofiltration technology in industrial wastewater treatment processes on commercial scale.
引用
收藏
页码:11586 / 11603
页数:18
相关论文
共 50 条
  • [1] THERMODYNAMIC PROPERTIES OF AMORPHOUS AND CRYSTALLINE ETHYLENE GLYCOL-WATER SOLUTION
    MILNES, MV
    ZANELLA, FM
    JOURNAL OF CHEMICAL PHYSICS, 1965, 42 (08): : 2817 - &
  • [2] Molecular Structure of an Ethylene Glycol-Water Solution at 298 K
    Loskutov, V. V.
    Kosova, G. N.
    RUSSIAN JOURNAL OF PHYSICAL CHEMISTRY A, 2019, 93 (02) : 260 - 264
  • [3] Effect of common water contaminants on the corrosion of aluminium alloys in ethylene glycol-water solution
    Abiola, Olusegun K.
    Otaigbe, J. O. E.
    CORROSION SCIENCE, 2008, 50 (01) : 242 - 247
  • [4] Mechanistic aspects of electrochemical corrosion of aluminum alloy in ethylene glycol-water solution
    Zhang, G. A.
    Xu, L. Y.
    Cheng, Y. F.
    ELECTROCHIMICA ACTA, 2008, 53 (28) : 8245 - 8252
  • [5] Separation of Ethylene Glycol-Water Mixtures with Composite Poly(vinyl alcohol)-Polypropylene Membranes
    Shahverdi, Mahnaz
    Mohammadi, Toraj
    Pak, Afshin
    JOURNAL OF APPLIED POLYMER SCIENCE, 2011, 119 (03) : 1704 - 1710
  • [6] Corrosion behavior of AISI321 stainless steel in an ethylene glycol-water solution
    Zhang, Xiaoguang
    Liu, Xiang
    Dong, Wenping
    Fan, Endian
    Bai, Ziheng
    Hu, Gengkai
    Yi, Pan
    Xiao, Kui
    Huang, Yunhua
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (03): : 2683 - 2692
  • [7] Electrochemical characterization of metastable pitting of 3003 aluminum alloy in ethylene glycol-water solution
    Niu, Lin
    Cheng, Y. Frank
    JOURNAL OF MATERIALS SCIENCE, 2007, 42 (20) : 8613 - 8617
  • [8] Effect of temperature on corrosion behavior of 3003 aluminum alloy in ethylene glycol-water solution
    Chen Xin
    Tian Wenming
    Li Songmei
    Yu Mei
    Liu Jianhua
    CHINESE JOURNAL OF AERONAUTICS, 2016, 29 (04) : 1142 - 1150
  • [9] Spectrophotometric Determination of Phosphate Anion Based on the Formation of Molybdophosphate in Ethylene Glycol-Water Mixed Solution
    Hajime Katano
    Tadaharu Ueda
    Analytical Sciences, 2011, 27 : 1043 - 1047
  • [10] Electrodeposition of nickel from its sulphate salt in a ethylene glycol-water mixture
    Sarabi, R. Sadeghi
    Meshkatalsadat, Mohammad Hadi
    Dargahi, M. T.
    ASIAN JOURNAL OF CHEMISTRY, 2007, 19 (06) : 4825 - 4830