Laboratory Test Study on Pile Jacking Penetration Mechanism Considering Different Diameter and Length Based on Photoelectric Integration Technology

被引:0
|
作者
Wang, Lifeng [1 ]
Zhang, Shuo [2 ]
Li, Shiqiang [3 ]
Wang, Jun [3 ]
Niu, Xunlong [3 ]
Wang, Donglei [4 ,5 ]
Wang, Yonghong [2 ]
机构
[1] Qingdao Fangshuo Construct Technol Co Ltd, Qingdao 266000, Peoples R China
[2] Qingdao Univ Technol, Sch Civil Engn, Qingdao 266033, Peoples R China
[3] China State Construct Zhongxin Construct Engn Co L, Qingdao 266033, Peoples R China
[4] Qingdao Green Technol Geotech Engn Co Ltd, Qingdao 266033, Peoples R China
[5] Qingdao Yongyuan Marine Technol Co Ltd, Qingdao 266033, Peoples R China
关键词
FBG sensor; spoke type pressure sensor; static pile; force state; BEARING CAPACITY; PIPE PILES; SAND; SOIL;
D O I
10.3390/buildings13051247
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Model tests are carried out on the jacked single piles of different diameters and pile lengths under the model pile of different diameters and pile lengths in clayey soil, which aims to investigate the penetration mechanical mechanism. How to accurately test the pile end resistance and pile side resistance during jacked pile sinking is particularly important. In this paper, a full-section spoke-type pressure sensor, a double diaphragm temperature self-compensating fiber Bragg grating (FBG) earth pressure sensor and a sensitized miniature FBG strain sensor are jointly applied to a single pile penetration model test to test a single pile driving force, pile end resistance and pile body stress during penetration. The test results show that the load transfer performance of test piles will be affected by different diameters, and the axial force transfer capability of a large diameter in the depth direction is better than that of a small diameter since the compacting effect is more obvious. The unit skin friction of the pile increases gradually as the depth increases, which is larger due to the lateral extrusion force increasing as the diameter increases. At the same depth, the unit skin friction of two different diameter piles demonstrates "friction fatigue", which also decreases obviously as the depth increases. Under the conditions of this test, the maximum frictional resistance of the pile TP1 pile side is about 27.7% higher than that of the test pile TP2. In the static pile sinking process of three test piles in cohesive soil, 50% is end bearing; therefore, there is 50% friction, and the diameter influences the end bearing and the length influences the friction.
引用
收藏
页数:16
相关论文
共 1 条
  • [1] Laboratory test comparative study on open-close piles during jacked pile-jacking based on pile-soil interface stress measurement
    Wang Y.
    Zhang M.
    Liu X.
    Bai X.
    Sang S.
    Guan J.
    Zhongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Central South University (Science and Technology), 2021, 52 (02): : 599 - 606