Design considerations for patient-specific bone fixation plates: a literature review

被引:4
|
作者
de Koning, S. G. Brouwer [1 ]
de Winter, N. [1 ]
Moosabeiki, V. [2 ]
Mirzaali, M. J. [2 ]
Berenschot, A. [3 ]
Witbreuk, M. M. E. H. [4 ]
Lagerburg, V. [1 ]
机构
[1] OLVG Hosp, Med Phys, Oosterpark 9,, NL-1091 AC Amsterdam, Netherlands
[2] Delft Univ Technol, Fac Mech Maritime & Mat Engn, Dept Biomech Engn, Delft, Netherlands
[3] OLVG Hosp, Dept Res & Epidemiol, Med Lib, Amsterdam, Netherlands
[4] OLVG Hosp, Orthoped Surg, Amsterdam, Netherlands
关键词
Bone plate; Fracture fixation; Patient-specific; Biomechanical properties; Orthopedics; LOCKING COMPRESSION PLATE; BIOMECHANICAL EVALUATION; FEMORAL PLATES; FRACTURE; SCREW; RECONSTRUCTION; OPTIMIZATION; PERFORMANCE; STIFFNESS; IMPLANTS;
D O I
10.1007/s11517-023-02900-4
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In orthopedic surgery, patient-specific bone plates are used for fixation when conventional bone plates do not fit the specific anatomy of a patient. However, plate failure can occur due to a lack of properly established design parameters that support optimal biomechanical properties of the plate.This review provides an overview of design parameters and biomechanical properties of patient-specific bone plates, which can assist in the design of the optimal plate.A literature search was conducted through PubMed and Embase, resulting in the inclusion of 78 studies, comprising clinical studies using patient-specific bone plates for fracture fixation or experimental studies that evaluated biomechanical properties or design parameters of bone plates. Biomechanical properties of the plates, including elastic stiffness, yield strength, tensile strength, and Poisson's ratio are influenced by various factors, such as material properties, geometry, interface distance, fixation mechanism, screw pattern, working length and manufacturing techniques.Although variations within studies challenge direct translation of experimental results into clinical practice, this review serves as a useful reference guide to determine which parameters must be carefully considered during the design and manufacturing process to achieve the desired biomechanical properties of a plate for fixation of a specific type of fracture.
引用
收藏
页码:3233 / 3252
页数:20
相关论文
共 50 条
  • [1] Design considerations for patient-specific bone fixation plates: a literature review
    S. G. Brouwer de Koning
    N. de Winter
    V. Moosabeiki
    M. J. Mirzaali
    A. Berenschot
    M. M. E. H. Witbreuk
    V. Lagerburg
    [J]. Medical & Biological Engineering & Computing, 2023, 61 : 3233 - 3252
  • [2] Biomechanical considerations in the design of patient-specific fixation plates for the distal radius
    G. Caiti
    J. G. G. Dobbe
    E. Bervoets
    M. Beerens
    S. D. Strackee
    G. J. Strijkers
    G. J. Streekstra
    [J]. Medical & Biological Engineering & Computing, 2019, 57 : 1099 - 1107
  • [3] Biomechanical considerations in the design of patient-specific fixation plates for the distal radius
    Caiti, G.
    Dobbe, J. G. G.
    Bervoets, E.
    Beerens, M.
    Strackee, S. D.
    Strijkers, J.
    Streekstra, G. J.
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2019, 57 (05) : 1099 - 1107
  • [4] Parametric design of patient-specific fixation plates for distal femur fractures
    Chen, Xiaozhong
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2018, 232 (09) : 901 - 911
  • [5] A method for optimal fit of patient-specific fracture fixation plates
    Harith, Hazreen
    Malekani, Javad
    Schmutz, Beat
    Schuetz, Michael
    Yarlagadda, Prasad K. D. V.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART L-JOURNAL OF MATERIALS-DESIGN AND APPLICATIONS, 2016, 230 (01) : 282 - 290
  • [6] Spinal Cord Stimulation and the Pregnant Patient-Specific Considerations for Management: A Case Series and Review of the Literature
    Bernardini, Donald J.
    Pratt, Stephen D.
    Takoudes, Tamara C.
    Simopoulos, Thomas T.
    [J]. NEUROMODULATION, 2010, 13 (04): : 270 - 274
  • [7] Three-dimensional design optimisation of patient-specific femoral plates as a means of bone remodelling reduction
    Nobari, S.
    Katoozian, H. R.
    Zomorodimoghadam, S.
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2010, 13 (06) : 819 - 827
  • [8] Design process of patient-specific osteosynthesis plates using topology optimization
    Park, Si-Myung
    Park, Soyeon
    Park, Jieun
    Choi, Minwook
    Kim, Laehyun
    Noh, Gunwoo
    [J]. JOURNAL OF COMPUTATIONAL DESIGN AND ENGINEERING, 2021, 8 (05) : 1257 - 1266
  • [9] Thin patient-specific clavicle fracture fixation plates can mechanically outperform commercial plates: An in silico approach
    Vancleef, Sanne
    Wesseling, Mariska
    Duflou, Joost R.
    Nijs, Stefaan
    Jonkers, Ilse
    Vander Sloten, Jos
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2022, 40 (07) : 1695 - 1706
  • [10] Patient-specific instrumentation for total knee arthroplasty: a literature review
    Camarda L.
    D’Arienzo A.
    Morello S.
    Peri G.
    Valentino B.
    D’Arienzo M.
    [J]. MUSCULOSKELETAL SURGERY, 2015, 99 (1) : 11 - 18