Vertebrae Transmission Probe Testing - Preliminary Bone Measurements

被引:0
|
作者
Meaney, Paul [1 ,2 ]
Mattsson, Viktor [1 ]
Augustine, Robin [1 ]
Rydholm, Tomas [3 ]
Brisby, Helena [4 ]
机构
[1] Uppsala Univ, Angstrom Lab, Uppsala, Sweden
[2] Dartmouth Coll, Thayer Sch Engn, Hanover, NH 03755 USA
[3] Fridagymnasiet, Molnlycke, Sweden
[4] Sahlgrens Univ Hosp, Gothenburg, Sweden
来源
2023 17TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION, EUCAP | 2023年
关键词
vertebrae; transmission probe; far-field; dielectric properties;
D O I
10.23919/EuCAP57121.2023.10133241
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We are developing a new transmission-based probe for assessing vertebrae strength via the differences between the dielectric properties of normal and osteoporotic bone. The probes are simple open-ended coaxial cables that will fit easily into the pedicle canals drilled by the surgeons before implanting screws to secure the supporting instrumentation. If the screws pull because of bone weakness, it can inflict a wide range of complications. In the progression towards actual clinical trials, we have already validated the approach on different liquids with varying dielectric properties. In this study, we assess actual animal bone samples as a precursor to human investigations. We exploit the fact that the trabecular bone is considerably different on opposite sides of the growth plate of long bones such as the femur - somewhat mimicking differences between normal and osteoporotic bone. For these experiments, we show that the properties of the distal and proximal sections are considerably different and present opportunities to exploit them in a diagnostic setting
引用
收藏
页数:3
相关论文
共 50 条
  • [1] Vertebrae cancellous bone strength measurements by an osteopenetrometer
    Logins, V
    Pontaga, I
    Saulgozis, J
    MECHANICS OF COMPOSITE MATERIALS, 1996, 32 (04) : 391 - 397
  • [3] A new probe for accurate velocity measurements in axial transmission technique: Application to cortical bone evaluation
    Bossy, E
    Talmant, M
    Defontaine, M
    Patat, F
    Laugier, P
    ACOUSTICAL IMAGING, VOL 27, 2004, 27 : 635 - 642
  • [4] Bone Mineral Density Measurements of Lumbar Vertebrae by Quantitative Computed Tomography
    Riaz, Hassan
    Khan, Obaid Ullah
    Akram, Hamid
    RAWAL MEDICAL JOURNAL, 2009, 34 (01): : 4 - +
  • [5] Preliminary Results on Trabecular Bone Score (Tbs) in Lumbar Vertebrae with Experimentally Altered Microarchitecture
    Di Stefano, M.
    Isaia, G. C.
    Cussa, D.
    Panattoni, G. L.
    JOURNAL OF BIOLOGICAL RESEARCH-BOLLETTINO DELLA SOCIETA ITALIANA DI BIOLOGIA SPERIMENTALE, 2013, 86 (01): : 16 - 18
  • [6] A multivariate method for classifying third to seventh cervical newborn vertebrae using bone measurements
    Castellana, C
    Kósa, F
    JOURNAL OF FORENSIC SCIENCES, 2001, 46 (06) : 1434 - 1437
  • [7] CERVICAL VERTEBRAE MEASUREMENTS IN SYRINGOMYELIA
    LEE, J
    WILLIAMS, B
    CLINICAL RADIOLOGY, 1977, 28 (04) : 395 - 400
  • [8] Light amplification in silicon nanocrystals by pump and probe transmission measurements
    Dal Negro, L
    Cazzanelli, M
    Danese, B
    Pavesi, L
    Iacona, F
    Franzò, G
    Priolo, F
    JOURNAL OF APPLIED PHYSICS, 2004, 96 (10) : 5747 - 5755
  • [9] BONE SCINTISCANNING AND DISEASES OF THE VERTEBRAE
    ROQUES, CF
    SIMON, J
    FOURNIE, A
    GUIRAUD, R
    RUFFIE, R
    REVUE DE MEDECINE DE TOULOUSE, 1979, 15 (02): : 97 - 99
  • [10] Cold vertebrae on bone scintigraphy
    Sopov, V
    Liberson, A
    Gorenberg, M
    Groshar, D
    SEMINARS IN NUCLEAR MEDICINE, 2001, 31 (01) : 82 - 83