Simulation of the response of SiPMs Part II: With saturation effects

被引:3
|
作者
Klanner, R. [1 ]
机构
[1] Univ Hamburg, Inst Expt Phys, Luruper Chaussee 149, D-22761 Hamburg, Germany
关键词
Silicon photo-multiplier; Simulation program; Non-linearity; Saturation effects; SILICON PHOTOMULTIPLIERS;
D O I
10.1016/j.nima.2023.169018
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A Monte Carlo program is presented which simulates the response of SiPMs in the nonlinear regime, where the number of Geiger discharges from photons and/or from dark counts in the time interval given by the pulse shape of a single Geiger discharge, approaches or exceeds the number of SiPM pixels. The model includes the effects of after-pulses, of prompt and delayed cross-talk, and of the voltage drop over the load resistance of the readout electronics. The results of the simulation program are compared to published results from SiPMs with different number of pixels for different intensities and time distributions of photons, dark-count rates, SiPM pulse shapes, and probabilities of cross-talk and after-pulsing.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Simulation of the response of SiPMs; Part I: Without saturation effects
    Garutti, E.
    Klanner, R.
    Rolph, J.
    Schwandt, J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 1019
  • [2] Effects of DCR, PDE and Saturation on the Energy Resolution of Digital SiPMs for PET
    Braga, Leo H. C.
    Perenzoni, Matteo
    Stoppa, David
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [3] Electrical characterization and simulation of SiPMs
    Scheuch, Florian
    Rihren, Daniel
    Hebbeker, Thomas
    Heidemann, Carsten
    Merschmeyer, Markus
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 787 : 340 - 343
  • [4] Over saturation behavior of SiPMs at high photon exposure
    Gruber, L.
    Brunner, S. E.
    Marton, J.
    Suzuki, K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 737 : 11 - 18
  • [5] Understanding the Nonlinear Response of SiPMs
    Moya-Zamanillo, Victor
    Rosado, Jaime
    SENSORS, 2024, 24 (08)
  • [6] Monte Carlo simulation of SiPMs with GATE
    Mehadji, Brahim
    Dupont, Mathieu
    Fougeron, Denis
    Morel, Christian
    JOURNAL OF INSTRUMENTATION, 2022, 17 (09):
  • [7] Frontiers of simulation, Part II
    Post, D
    COMPUTING IN SCIENCE & ENGINEERING, 2004, 6 (03) : 16 - 17
  • [8] Simulation of saturation effects in electroabsorption modulators
    Wiedenhaus, M
    Ahland, A
    Schulz, D
    AEU-INTERNATIONAL JOURNAL OF ELECTRONICS AND COMMUNICATIONS, 2001, 55 (05) : 323 - 327
  • [9] Simulation of saturation effects in electroabsorption modulators
    Wiedenhaus, Marco
    Ahland, Andreas
    Schulz, Dirk
    AEU-Archiv fur Elektronik und Ubertragungstechnik, 2001, 55 (05): : 323 - 327
  • [10] Effects of dispersed fibres in myocardial mechanics, Part II: active response
    Guan, Debao
    Wang, Yingjie
    Xu, Lijian
    Cai, Li
    Luo, Xiaoyu
    Gao, Hao
    MATHEMATICAL BIOSCIENCES AND ENGINEERING, 2022, 19 (04) : 4101 - 4119