Label-Free, Impedance-Based Biosensor for Kidney Disease Biomarker Uromodulin

被引:3
|
作者
Vora, Kunj [1 ]
Kordas, Norbert [1 ]
Seidl, Karsten [1 ,2 ]
机构
[1] Fraunhofer Inst Microelect Circuits & Syst, D-47057 Duisburg, Germany
[2] Univ Duisburg Essen, Dept Elect Components & Circuits, Forsthausweg 2, D-47057 Duisburg, Germany
关键词
impedance spectroscopy; atomic layer deposition; tantalum pentoxide; uromodulin; chronic kidney disease; ATOMIC LAYER DEPOSITION; CAPACITANCE; ELECTRODES;
D O I
10.3390/s23249696
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We demonstrate the development of a label-free, impedance-based biosensor by using a passivation layer of 50-nm tantalum pentoxide (Ta2O5) on interdigitated electrodes (IDE). This layer was fabricated by atomic layer deposition (ALD) and has a high dielectric constant (high-kappa), which improves the capacitive property of the IDE. We validate the biosensor's performance by measuring uromodulin, a urine biomarker for kidney tubular damage, from artificial urine samples. The passivation layer is functionalized with uromodulin antibodies for selective binding. The passivated IDE enables the non-faradaic impedance measurement of uromodulin concentrations with a measurement range from 0.5 ng/mL to 8 ng/mL and with a relative change in impedance of 15 % per ng/mL at a frequency of 150 Hz (log scale). This work presents a concept for point-of-care biosensing applications for disease biomarkers.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Development of a label-free, impedance-based biosensor to identify harmful effects of pesticides on insect cells
    Friedrich S.
    Malagimani N.
    Michaelis S.
    Wegener J.
    Applied Research, 2024, 3 (05):
  • [2] A Low-Voltage and Label-Free Impedance-based Miniaturized CMOS Biosensor for DNA Detection
    Fan, Vinny Lam Siu
    Hwan, Wong How
    Yusof, Yusmeeraz
    JURNAL TEKNOLOGI, 2014, 67 (01):
  • [3] A Label-free, Rapid Multimarker Protein Impedance-based Immunosensor
    Fairchild, Aaron B.
    McAferty, Kenyon
    Demirok, Ugur K.
    La Belle, Jeffrey T.
    2009 ICME INTERNATIONAL CONFERENCE ON COMPLEX MEDICAL ENGINEERING, 2009, : 170 - 174
  • [4] Label-free leukocyte sorting and impedance-based profiling for diabetes testing
    Petchakup, Chayakorn
    Tay, Hui Min
    Yeap, Wei Hseun
    Dalan, Rinkoo
    Wong, Siew Cheng
    Li, King Ho Holden
    Hou, Han Wei
    BIOSENSORS & BIOELECTRONICS, 2018, 118 : 195 - 203
  • [5] On-chip label-free impedance-based detection of antibiotic permeation
    Kaur, Jaspreet
    Ghorbanpoor, Hamed
    Ozturk, Yasin
    Kaygusuz, Ozge
    Avci, Huseyin
    Darcan, Cihan
    Trabzon, Levent
    Guzel, Fatma D.
    IET NANOBIOTECHNOLOGY, 2021, 15 (01) : 100 - 106
  • [6] Evaluation of Impedance-Based Label-Free Technology as a Tool for Pharmacology and Toxicology Investigations
    Atienzar, Franck Andre
    Gerets, Helga
    Tilmant, Karen
    Toussaint, Gaelle
    Dhalluin, Stephane
    BIOSENSORS-BASEL, 2013, 3 (01): : 132 - 156
  • [7] Label-free monitoring of T cell activation by the impedance-based xCELLigence system
    Guan, Ni
    Deng, Jiejie
    Li, Ting
    Xu, Xiao
    Irelan, Jeffrey T.
    Wang, Ming-Wei
    MOLECULAR BIOSYSTEMS, 2013, 9 (05) : 1035 - 1043
  • [8] Impedance-Based Nanoporous Anodized Alumina/ITO Platforms for Label-Free Biosensors
    Devarakonda, Sivaranjani
    Ganapathysubramanian, Baskar
    Shrotriya, Pranav
    ACS APPLIED MATERIALS & INTERFACES, 2022, 14 (01) : 150 - 158
  • [9] Label-free impedance-based aptasensor for Escherichia coli detection in real matrices
    Yousefniayejahromi, Z.
    Sembranti, L.
    Vivaldi, F.
    Bonini, A.
    Poma, N.
    Tavanti, A.
    Di Francesco, F.
    MICROCHEMICAL JOURNAL, 2025, 208
  • [10] Label-free impedance-based whole cell assay to study GPCR pharmacology
    Doornbos, Maarten L. J.
    Heitman, Laura H.
    G PROTEIN-COUPLED RECEPTORS, PT B, 2019, 149 : 179 - +