Development of soft X-ray ptychography and fluorescence microscopy system using total-reflection wolter mirror and application to measurement of drug-treated mammalian cells

被引:0
|
作者
Takeo, Yoko [1 ,2 ]
Sakurai, Kai [3 ]
Furuya, Noboru [3 ]
Yoshinaga, Kyota [3 ]
Shimamura, Takenori [2 ,4 ]
Egawa, Satoru [4 ]
Kiuchi, Hisao [1 ]
Mimura, Hidekazu [4 ]
Ohashi, Haruhiko [2 ,5 ]
Harada, Yoshihisa [1 ]
Shimura, Mari [5 ,6 ]
Kimura, Takashi [1 ]
机构
[1] Univ Tokyo, Inst Solid State Phys, 5-1-5 Kashiwanoha, Kashiwa, Chiba 2778581, Japan
[2] Japan Synchrotron Radiat Res Inst, 1-1-1 Kouto, Sayo, Hyogo 6795198, Japan
[3] Univ Tokyo, Sch Engn, Dept Appl Phys, 7-3-1 Hongo, Bunkyo Ku, Tokyo 1138656, Japan
[4] Univ Tokyo, Sch Engn, Dept Precis Engn, 7-3-1 Hongo, Bunkyo Ku, Tokyo 1138656, Japan
[5] RIKEN, SPring 8 Ctr, 1-1-1 Kouto, Sayo, Hyogo 6795148, Japan
[6] Natl Ctr Global Hlth & Med, Res Inst, Tokyo 1628655, Japan
关键词
X-ray ptychography; X-ray Fluorescence; Soft X-ray microscopy; Wolter mirror; HepG2; GRL-142;
D O I
10.1016/j.elspec.2023.147380
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
We developed a soft X-ray microscopic imaging system, CARROT, that combines ptychography and fluorescence X-ray microscopy using a total-reflection Wolter mirror illumination system. The system offers advantages such as achromaticity and long working distances, enabling seamless application to a wide wavelength range. We demonstrated high-resolution imaging of cellular structures and sub-micrometer-scale changes induced by drug administration in mammalian cells. We further showcased the capability to seamlessly switch from ptychography measurements to X-ray fluorescence measurements at different wavelengths to map elemental distributions within cells. Our findings suggest that this system can be used for investigating the correlation between intra-cellular structures and elemental distribution, as well as for multimodal measurements of visible light fluores-cence, Raman scattering, and soft X-rays to provide valuable insights into understanding intracellular dynamics.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Soft X-ray ptychography system using a Wolter mirror for achromatic illumination optics
    Kimura, Takashi
    Takeo, Yoko
    Sakurai, Kai
    Furuya, Noboru
    Egawa, Satoru
    Yamaguchi, Gota
    Matsuzawa, Yusuke
    Kume, Takehiro
    Mimura, Hidekazu
    Shimura, Mari
    Ohashi, Haruhiko
    Matsuda, Iwao
    Harada, Yoshihisa
    OPTICS EXPRESS, 2022, 30 (15): : 26220 - 26228
  • [2] Bioanalytical Application of the Total-Reflection X-Ray Fluorescence Spectrometry
    Fernandez-Ruiz, Ramon
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2025, 26 (03)
  • [3] A total-reflection X-ray fluorescence spectrometer using a rotating anode
    Pettersson, RP
    Boman, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 371 (03): : 553 - 559
  • [4] Total-reflection x-ray fluorescence spectrometer using a rotating anode
    Chalmers Univ of Technology, Goteborg, Sweden
    Nucl Instrum Methods Phys Res Sect A, 3 (553-559):
  • [5] TOTAL-REFLECTION X-RAY-FLUORESCENCE ANALYSIS USING SPECIAL X-RAY SOURCES
    WOBRAUSCHEK, P
    KREGSAMER, P
    LADISICH, W
    RIEDER, R
    STRELI, C
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1993, 48 (02) : 143 - 151
  • [6] Determination of mercury by total-reflection X-ray fluorescence using amalgamation with gold
    Bennun, L
    Gomez, J
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (08) : 1195 - 1200
  • [7] TOTAL-REFLECTION X-RAY FLUORESCENCE ANALYSIS USING MONOCHROMATIC BEAM.
    Iida, Atsuo
    Gohshi, Yohichi
    1600, (23):
  • [8] Determination of mercury by total-reflection X-ray fluorescence using amalgamation with gold
    Centro Atomico Bariloche, Bariloche, Argentina
    Spectrochim Acta Part B At Spectrosc, 8 (1195-1200):
  • [9] Preliminary classification of polymers by using total-reflection X-ray fluorescence spectra
    Boeykens, S
    Vázquez, C
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (08) : 1189 - 1192
  • [10] Calibration of total-reflection X-ray fluorescence using a nickel bulk sample
    Knoth, J
    Beaven, P
    Schwenke, H
    Dobler, M
    Reus, U
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (11) : 2275 - 2281