The SNR of time-of-flight positron emission tomography data for joint reconstruction of the activity and attenuation images

被引:0
|
作者
Nuyts, Johan [1 ,2 ]
Defrise, Michel [3 ]
Morel, Christian [4 ]
Lecoq, Paul [5 ]
机构
[1] Univ Leuven, Dept Imaging & Pathol, KU Leuven, Nucl Med & Mol imaging, B-3000 Leuven, Belgium
[2] Med Imaging Res Ctr MIRC, B-3000 Leuven, Belgium
[3] Vrije Univ Brussel, Dept Nucl Med, B-1090 Brussels, Belgium
[4] Aix Marseille Univ, CNRS, IN2P3, CPPM, Marseille, France
[5] Univ Politecn Valencia, Valencia, Spain
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2024年 / 69卷 / 01期
关键词
SNR; positron emission tomography; reconstruction; variance; PET; LIKELIHOOD; RESOLUTION;
D O I
10.1088/1361-6560/ad078c
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Measurement of the time-of-flight (TOF) difference of each coincident pair of photons increases the effective sensitivity of positron emission tomography (PET). Many authors have analyzed the benefit of TOF for quantification and hot spot detection in the reconstructed activity images. However, TOF not only improves the effective sensitivity, it also enables the joint reconstruction of the tracer concentration and attenuation images. This can be used to correct for errors in CT- or MR-derived attenuation maps, or to apply attenuation correction without the help of a second modality. This paper presents an analysis of the effect of TOF on the variance of the jointly reconstructed attenuation and (attenuation corrected) tracer concentration images. Approach. The analysis is performed for PET systems that have a distribution of possibly non-Gaussian TOF-kernels, and includes the conventional Gaussian TOF-kernel as a special case. Non-Gaussian TOF-kernels are often observed in novel detector designs, which make use of two (or more) different mechanisms to convert the incoming 511 keV photon to optical photons. The analytical result is validated with a simple 2D simulation. Main results. We show that if two different TOF-kernels are equivalent for image reconstruction with known attenuation, then they are also equivalent for joint reconstruction of the activity and the attenuation images. The variance increase in the activity, caused by also jointly reconstructing the attenuation image, vanishes when the TOF-resolution approaches perfection. Significance. These results are of interest for PET detector development and for the development of stand-alone PET systems.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] FEASIBILITY OF TIME-OF-FLIGHT RECONSTRUCTION IN POSITRON EMISSION TOMOGRAPHY
    MULLANI, NA
    MARKHAM, J
    TERPOGOSSIAN, MM
    JOURNAL OF NUCLEAR MEDICINE, 1980, 21 (11) : 1095 - 1097
  • [2] Joint estimation of activity image and attenuation sinogram using time-of-flight positron emission tomography data consistency condition filtering
    Li Q.
    Li H.
    Kim K.
    El Fakhri G.
    Li, Quanzheng (li.quanzheng@mgh.harvard.edu), 1600, SPIE (04):
  • [3] Iterative Simultaneous Attenuation Correction and Activity Estimation for Time-of-Flight Positron Emission Tomography
    Lee, Nam-Yong
    Kim, You Suk
    Lim, Hyun Keong
    Choi, Yong
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2020, 77 (08) : 689 - 699
  • [4] Iterative Simultaneous Attenuation Correction and Activity Estimation for Time-of-Flight Positron Emission Tomography
    Nam-Yong Lee
    You Suk Kim
    Hyun Keong Lim
    Yong Choi
    Journal of the Korean Physical Society, 2020, 77 : 689 - 699
  • [5] Windowed image reconstruction for time-of-flight positron emission tomography
    Kao, Chien-Min
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (13): : 3431 - 3445
  • [6] Deconvolution based attenuation correction for time-of-flight positron emission tomography
    Nam-Yong Lee
    Journal of the Korean Physical Society, 2017, 71 : 426 - 437
  • [7] Deconvolution based attenuation correction for time-of-flight positron emission tomography
    Lee, Nam-Yong
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2017, 71 (07) : 426 - 437
  • [8] Evaluation of Joint Reconstruction of Activity and Attenuation in Time-of-Flight PET
    Wang, Jingnan
    Wang, Tong
    Zhu, Wenjia
    Zhang, Yue
    Li, Nan
    Zhang, Hui
    Huo, Li
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [9] One-View Time-of-Flight Positron Emission Tomography Reconstruction
    Zeng, Gengsheng L.
    Huang, Qiu
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2021, 5 (05) : 723 - 728
  • [10] Instrumentation for Time-of-Flight Positron Emission Tomography
    Ullah M.N.
    Pratiwi E.
    Cheon J.
    Choi H.
    Yeom J.Y.
    Nuclear Medicine and Molecular Imaging, 2016, 50 (2) : 112 - 122