A dosimetric study of occupational exposure during computed tomography procedures

被引:1
|
作者
Silva, Monique F. [1 ]
Caixeta, Ana L. O. [1 ]
Souza, Samara P. [1 ]
Costa, Paulo R. [2 ]
Santos, William S. [1 ,3 ]
Neves, Lucio P. [1 ,3 ]
Perini, Ana P. [1 ,3 ]
机构
[1] Univ Fed Uberlandia, Fac Elect Engn, Postgrad Program Biomed Engn PPGEB, Uberlandia, MG, Brazil
[2] Univ Sao Paulo, Inst Phys, Sao Paulo, SP, Brazil
[3] Univ Fed Uberlandia, Inst Phys, Uberlandia, MG, Brazil
基金
巴西圣保罗研究基金会;
关键词
CT exams; Chest; Personal dosimetry; Monte Carlo simulation; RADIATION PROTECTION; CT-FLUOROSCOPY; MEDICAL STAFF; MASH FEMALE; PHANTOMS; LENS; SPECTRA; CANCER; FASH;
D O I
10.1016/j.radphyschem.2024.111564
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The number of chest computed tomography (CT) procedures has increased worldwide as it is a diagnostic tool for a variety of lung diseases, mainly for visualizing and monitoring lung extensions and impairments. Due to respiratory problems in patients during the CT scan, health professionals need to perform special care such as BagValve-Mask Ventilation and accompany them throughout the procedure. Therefore, this study aimed to investigate and evaluate the doses received by these professionals during a chest CT study. The effectiveness of personal protective equipment (PPE) was also evaluated. To achieve these objectives, computational scenarios were simulated with pediatric (1 and 10 years old) and adult virtual anthropomorphic phantoms, representing patients and professionals. Conversion coefficients for equivalent (CC[HT]) and effective (CC([E]) doses were determined using the MCNP 6.2 Monte Carlo code. The results obtained showed that the highest dose effective [E] values were for the professional positioned in front of the gantry and without the use of PPE, ranging from around 5.78 x 10-2 to 1.82 x 10-1 mSv, depending on the patient size monitored during the examination and the x-ray tube voltage. The organs of the simulated professionals with the highest CC[HT] values were the breasts (female) and testicles (male). Furthermore, the use of PPE demonstrate reductions on CC[HT] and CC([E] values of the professional of approximately 91 %.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Radiation exposure estimation in pediatric patients during computed tomography imaging procedures
    Sulieman, Abdelmoneim
    Almogren, Kholoud S.
    Tamam, Nissren
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2023, 204
  • [2] Occupational Dust Exposure And COPD Using Computed Tomography
    Vedal, S.
    Kimball, S.
    Cohen, M. A.
    New, E.
    Grydeland, T.
    Coxson, H. O.
    Skorge, T.
    Dirksen, A.
    Bakke, P.
    Gulsvik, A.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2015, 191
  • [3] Occupational noise exposure during endourologic procedures
    Soucy, Frederic
    Ko, Raymond
    Denstedt, John D.
    Razvi, Hassan
    [J]. JOURNAL OF ENDOUROLOGY, 2007, 21 : A89 - A89
  • [4] Occupational noise exposure during endourologic procedures
    Soucy, Frederic
    Ko, Raymond
    Denstedt, John D.
    Razvi, Hassan
    [J]. JOURNAL OF ENDOUROLOGY, 2008, 22 (08) : 1609 - 1611
  • [5] Assessment of Radiation Exposure and Attributed Risk During Chest, Abdominal and Pelvic Computed Tomography Procedures
    Mattar, Essam H.
    [J]. INTERNATIONAL JOURNAL OF BIOMEDICINE, 2022, 12 (01) : 115 - 119
  • [6] Occupational Radiation Exposure During Endovascular Aortic Procedures
    Patel, A. P.
    Gallacher, D.
    Dourado, R.
    Lyons, O.
    Smith, A.
    Zayed, H.
    Waltham, M.
    Sabharwal, T.
    Bell, R.
    Carrell, T.
    Taylor, P.
    Modarai, B.
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2013, 46 (04) : 424 - 430
  • [7] DOSIMETRIC INVESTIGATIONS IN COMPUTED-TOMOGRAPHY
    CHRISTENSEN, JJ
    JENSEN, LC
    JESSEN, KA
    JORGENSEN, J
    PETERSEN, J
    SORENSEN, EW
    [J]. RADIATION PROTECTION DOSIMETRY, 1992, 43 (1-4) : 233 - 236
  • [8] Associations between occupational exposure and quantitative computed tomography (qCT) measures of emphysema
    Skorge, Trude
    Svanes, Oistein
    Johannessen, Ane
    Grydeland, Thomas
    Coxon, Harvey
    Gulsvik, Amund
    Bakke, Per
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2012, 40
  • [9] A DOSIMETRIC EVALUATION OF CONE BEAM COMPUTED TOMOGRAPHY
    Alkhatib, H.
    Stenbeck, J.
    Higgins, P.
    Alaei, P.
    Tedeschi, D.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S478 - S479
  • [10] Lens exposure during computed tomography for elbow injuries in baseball players: a phantom study
    Oshima, Ryota
    Yamamoto, Kenyu
    Nunome, Hiroyuki
    [J]. GAZZETTA MEDICA ITALIANA ARCHIVIO PER LE SCIENZE MEDICHE, 2023, 182 (12) : 948 - 955