3D Synthetic Aperture Imaging Method in Spectrum Domain for Low-Cost Portable Ultrasound Systems

被引:0
|
作者
Tasinkiewicz, Jurij [1 ]
机构
[1] Polish Acad Warsaw, Inst Fundamental Technol Res, Warsaw, Poland
关键词
ultrasound imaging; matrix transducer; delay-and-sum; Fourier transform; synthetic aperture; TRANSMIT APERTURE; DESIGN; ARRAY;
D O I
10.24425/aoa.2023.146820
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Portable, hand-held ultrasound devices capable of 3D imaging in real time are the next generation of the medical imaging apparatus adapted not only for professional medical stuff but for a wide group of less advanced users. Limited power supply capacity and the relatively small number of channels used for the ultrasound data acquisition are the most important limitations that should be taken into account when designing such devices and when developing the corresponding image reconstruction algorithms.The aim of this study was to develop a new 3D ultrasound imaging method which would take into account the above-mentioned features of the new generation of ultrasonic devices - low-cost portable general access scanners.It was based on the synthetic transmit aperture (STA) method combined with the Fourier spectrum domain (SD) acoustic data processing. The STA using a limited number of elements in transmit and receive modes for ultrasound data acquisition allowed both aforementioned constraints to be obeyed simultaneously. Moreover, the computational speed of the fast Fourier transform (FFT) algorithm utilized for the ultrasound image synthesis in the spectrum domain makes the proposed method to be more competitive compared to the conventional time domain (TD) STA method based on the delay-and-sum (DAS) technique, especially in the case of 3D imaging in real time mode.Performance of the proposed method was verified using numerical 3D acoustic data simulated in the Field II program for MATLAB and using experimental data from the custom design 3D scattering phantom collected by means of the Verasonics Vantage 256TM research ultrasound system equipped with the dedicated 1024-element 2D matrix transducer.The method proposed in this paper was about 80 times faster than its counterpart based on the time domain synthetic transmit aperture (TD-STA) approach in the numerical example of a single 3D ultrasound image synthesized from 4 partial images each containing 64 x 64 x 512 pixels.It was also shown that the acceleration of the image reconstruction was achieved at the cost of a slight deterioration in the image quality assessed by the contrast and contrast-to-noise ratio (CNR).
引用
收藏
页码:559 / 572
页数:14
相关论文
共 50 条
  • [1] A portable, low-cost, highly integrated, 3D medical ultrasound system
    Fuller, MI
    Blalock, TN
    Hossack, JA
    Walker, WF
    2003 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2003, : 38 - 41
  • [2] Low Complexity 3D Ultrasound Imaging Using Synthetic Aperture Sequential Beamforming
    Zhou, Jian
    Wei, Siyuan
    Sampson, Richard
    Yang, Ming
    Jintamethasawat, Rungroj
    Kripfgans, Oliver D.
    Fowlkes, J. Brian
    Wenisch, Thomas F.
    Chakrabarti, Chaitali
    2016 IEEE INTERNATIONAL WORKSHOP ON SIGNAL PROCESSING SYSTEMS (SIPS), 2016, : 33 - 38
  • [3] 3D ultrasound imaging in frequency domain based on concepts of array beam and synthetic aperture
    Han, Zhihui
    Peng, Hu
    Zhao, Xiaoyan
    Chen, Xun
    ULTRASONICS, 2018, 84 : 254 - 263
  • [4] Design of Low-Cost Portable Ultrasound Systems: Review
    Baran, Jonathan M.
    Webster, John G.
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 792 - 795
  • [5] Low-cost portable imaging systems for cancer detection
    Pierce, Amark C.
    Schwarz, Arichard A.
    Shin, Dong-Suk
    Roblyer, Darren
    Muldoon, Tim
    Rahman, Mohammed
    Gillenwater, Ann M.
    Anandasabapathy, Sharmila
    Richards-Kortum, Rebecca
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES III, 2010, 7556
  • [6] Staphyloma 3D images created by a low-cost portable device
    Diogenes, Marcelo Bezerra
    Cardoso Pinto, Nayara Queiroz
    Souza Viana, Karlos Italo
    Costa, Dacio Carvalho
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2021, 84 (04) : 415 - 417
  • [7] A portable low-cost 3D point cloud acquiring method based on structure light
    Gui, Li
    Zheng, Shunyi
    Huang, Xia
    Zhao, Like
    Ma, Hao
    Ge, Chao
    Tang, Qiuxia
    MIPPR 2017: PATTERN RECOGNITION AND COMPUTER VISION, 2017, 10609
  • [8] 3D/4D hybrid spectral domain synthetic aperture image reconstruction method for hand-held ultrasound systems
    Tasinkevych, Yuriy
    Lewandowski, Marcin
    Walczak, Mateusz
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 2358 - 2361
  • [9] Efficient GPU Implementation of 3D Spectral Domain Synthetic Aperture Imaging
    Lewandowski, Marcin
    Jarosik, Piotr
    Tasinkevych, Yuriy
    Walczak, Mateusz
    PROCEEDINGS OF THE 2020 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2020,
  • [10] 3D Imaging with a Synthetic Aperture Radar
    Rozhentsov A.A.
    Leukhin A.N.
    Bezrodnyi V.I.
    Voronin A.A.
    Kokovihina N.A.
    Bulletin of the Russian Academy of Sciences: Physics, 2018, 82 (8) : 1068 - 1072