Increasingly challenging lifetime requirements for automotive Polymer-Electrolyte-Membrane (PEM) fuel cells call for onboard characterization methods to enable state-of-health (SOH) adaptive operation strategies. In this work, an adapted Galvanostatic Charge Method (GCM) is presented, that allows for cell-individual electrochemical characterization without nitrogen flush, making it system-and potentially onboard-compatible. Key innovation is to utilize the system's standard shutdown procedure, i.e. oxygen depletion with closed air valves, to create an inert atmosphere in the cathode volume in which the characterization takes place. The electrochemical processes triggered during the characterization with GCM are now embedded in a closed -volume-problem instead of a steady-flow-environment. This causes the hydrogen concentration difference between anode and cathode to be dynamic instead of constant during the characterization. In this work, a 0D-simulation model of the closed-volume-problem and complementary measurements on a system testbench are presented. Additionally, a novel model-based evaluation method is introduced which extracts the SOH -indicators electrochemical active surface area (ECSA), double layer capacity, hydrogen permeability of the membrane and short circuit resistance from the measurements by fitting simulated to measured voltage curves. The simulation model is thoroughly analyzed and a systematic error, evoked by the fluidic coupling of the individual cells, is found to influence the results obtained for membrane permeability. The influence of different initial conditions (among them initial hydrogen concentration) on the evaluation results is experimentally investigated and found to have no significant influence. For further studies, improvement potential was found in modeling, measurement procedure and evaluation method.
引用
收藏
页数:11
相关论文
共 39 条
  • [1] Method for in-situ determination of flow distribution in fuel cell stacks
    Kraaij, GJ
    Rietveld, B
    [J]. CARBONATE FUEL CELL TECHNOLOGY, 1999, 99 (20): : 368 - 370
  • [2] In-situ diagnostic tools for hydrogen transfer leak characterization in PEM fuel cell stacks part II: Operational applications
    Niroumand, Amir M.
    Homayouni, Hooman
    DeVaal, Jake
    Golnaraghi, Farid
    Kjeang, Erik
    [J]. JOURNAL OF POWER SOURCES, 2016, 322 : 147 - 154
  • [3] In-situ diagnostic tools for hydrogen transfer leak characterization in PEM fuel cell stacks part III: Manufacturing applications
    Niroumand, Amir M.
    Homayouni, Hooman
    Goransson, Gert
    Olfert, Mark
    Eikerling, Michael
    [J]. JOURNAL OF POWER SOURCES, 2020, 448
  • [4] In Situ Quantification of Electronic Short Circuits in PEM Fuel Cell Stacks
    De Moor, G.
    Charvin, N.
    Bas, C.
    Caque, N.
    Rossinot, E.
    Flandin, L.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (08) : 5275 - 5282
  • [5] Improved electrochemical in-situ characterization of polymer electrolyte membrane fuel cell stacks
    Hartung, I.
    Kirsch, S.
    Zihrul, P.
    Mueller, O.
    von Unwerth, T.
    [J]. JOURNAL OF POWER SOURCES, 2016, 307 : 280 - 288
  • [6] In-situ characterization of gas distribution in proton exchange membrane fuel cell stacks
    Ren, Peng
    Pei, Pucheng
    Li, Yuehua
    Chen, Dongfang
    Fu, Xi
    Zhu, Zijing
    Zhang, Lu
    Wang, Mingkai
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2022, 269
  • [7] IN-SITU POLYMERIZED WICKS FOR PASSIVE WATER MANAGEMENT IN PEM FUEL CELL SYSTEMS
    Strickland, Daniel G.
    Fenning, David
    Litster, Shawn
    Santiago, Juan G.
    [J]. ES2009: PROCEEDINGS OF THE ASME 3RD INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, VOL 1, 2009, : 325 - 326
  • [8] In-situ diagnostic tools for hydrogen transfer leak characterization in PEM fuel cell stacks part I: R&D applications
    Niroumand, Amir M.
    Pooyanfar, Oldooz
    Macauley, Natalia
    DeVaal, Jake
    Golnaraghi, Farid
    [J]. JOURNAL OF POWER SOURCES, 2015, 278 : 652 - 659
  • [9] Comprehensive analysis of galvanostatic charge method for fuel cell degradation diagnosis
    Hu, Zunyan
    Xu, Liangfei
    Huang, Yiyuan
    Li, Jianqiu
    Ouyang, Minggao
    Du, Xiaoli
    Jiang, Hongliang
    [J]. APPLIED ENERGY, 2018, 212 : 1321 - 1332
  • [10] A NOVEL HALF-CELL DESIGN AND FABRICATION FOR AN IN-SITU EVALUATION OF PEM FUEL CELL ELECTROCATALYSTS
    Zhang, Lei
    Kim, Jenny
    Singh, Shane
    Tsay, Ken
    Zhang, Jiujun
    [J]. INTERNATIONAL JOURNAL OF GREEN ENERGY, 2014, 11 (01) : 1 - 11