Repeatability and Reproducibility of Corneoscleral Topography Measured With Scheimpflug Imaging in Keratoconus and Control Eyes

被引:2
|
作者
Yang, Zhengfei [1 ]
Wang, Mengyi [1 ]
Li, Zhouyue [1 ]
Hu, Yin [1 ]
Jiang, Jinyun [1 ]
Yu, Fei [1 ]
Zeng, Junwen [1 ]
Chen, Weiyin [1 ]
Yang, Xiao [1 ,2 ]
机构
[1] Sun Yat Sen Univ, Zhongshan Ophthalm Ctr, State Key Lab Ophthalmol, Guangzhou, Peoples R China
[2] Sun Yat Sen Univ, Zhongshan Ophthalm Ctr, State Key Lab Ophthalmol, 54 S Xianlie Rd, Guangzhou 510060, Peoples R China
来源
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE | 2023年 / 49卷 / 06期
基金
中国国家自然科学基金;
关键词
Corneoscleral topography; Keratoconus; Pentacam; Repeatability; Scheimpflug imaging; SCLERAL SHAPE; RELIABILITY;
D O I
10.1097/ICL.0000000000000983
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objectives:To determine and compare the repeatability and reproducibility of anterior scleral parameters measured by the corneoscleral profile (CSP) module of Pentacam in keratoconus (KC) and control eyes.Methods:This is a prospective observational study. Thirty KC participants (30 eyes) and 24 control participants (24 eyes) were examined three times using the CSP. Sagittal height mean (SHM), sagittal height astigmatism (SHA), and mean bulbar slope (BSM) were measured in 12 mm and 16 mm chord lengths. The repeatability and reproducibility of these measurements were also assessed. Coefficients of variation (CoV), intraclass correlation coefficient (ICC), coefficient of repeatability (CoR1), and coefficient of reproducibility (CoR2) were adopted to assess the reliability.Results:In the KC and control groups, SHM showed high repeatability and reproducibility (coefficients of variation [CoVs]<= 0.96%, intraclass correlation coefficient [ICCs]>= 0.97), and SHM of control eyes showed higher repeatability and reproducibility than that of KC eyes at 12 mm chord length (KC group, CoRs ranged from 35.56 mu m to 43.52 mu m, control group, ranged from 23.50 mu m to 30.31 mu m) and 16 mm chord length (KC group, CoRs ranged from 79.54 mu m to 81.58 mu m, control group, ranged from 48.25 mu m to 66.10 mu m). Mean bulbar slope also showed high repeatability and reproducibility (CoVs <= 3.65%, CoRs <= 2.64). Furthermore, the SHA of control eyes showed higher repeatability and reproducibility when compared with KC eyes (control group: CoVs <= 29.95%, KC group: CoVs >= 32.67%).Conclusions:Keratoconus and control eyes demonstrated high repeatability and reproducibility when using CSP measurements, which may prove helpful in fitting contact lenses.
引用
收藏
页码:234 / 240
页数:7
相关论文
共 45 条
  • [1] Corneoscleral Topography Measured with Fourier-based Profilometry and Scheimpflug Imaging
    Bandlitz, Stefan
    Esper, Patrick
    Stein, Magdalena
    Dautzenberg, Torsten
    Wolffsohn, James S.
    OPTOMETRY AND VISION SCIENCE, 2020, 97 (09) : 766 - 774
  • [2] Repeatability and agreement of a Scheimpflug-Placido tomography and a Partial Coherence Interferometer in keratoconus and control eyes
    Ozkan, Yaprak
    Gokcinar, Nesrin Buyuktortop
    INTERNATIONAL OPHTHALMOLOGY, 2025, 45 (01)
  • [3] Evaluation of Scheimpflug imaging parameters in subclinical keratoconus, keratoconus, and normal eyes
    Ucakhan, Omur O.
    Cetinkor, Volkan
    Ozkan, Muhip
    Kanpolat, Ayfer
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (06): : 1116 - 1124
  • [4] Repeatability and reproducibility of corneal deformation response parameters of dynamic ultra-high-speed Scheimpflug imaging in keratoconus
    Herber, Robert
    Vinciguerra, Riccardo
    Lopes, Bernardo
    Raiskup, Frederik
    Pillunat, Lutz E.
    Vinciguerra, Paolo
    Ambrosio, Renato, Jr.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (01): : 86 - 94
  • [5] Repeatability and validity of lens densitometry measured with Scheimpflug imaging
    Kirkwood, Bradley J.
    Hendicott, Peter L.
    Read, Scott A.
    Pesudovs, Konrad
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (07): : 1210 - 1215
  • [6] Repeatability and agreement of two ocular biometers with single and dual Scheimpflug cameras in keratoconus eyes
    Lwowski, Christoph
    Krueger, Daniel
    Kohnen, Thomas
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, 262 (11) : 3701 - 3709
  • [7] Repeatability of Corneal Deformation Response Parameters by Dynamic Ultra High-speed Scheimpflug Imaging in Normal and Keratoconus Eyes
    Henriquez, Maria A.
    Gomez, Isabel
    Camino-Quezada, Maythe
    Izquierdo, Luis, Jr.
    Chauca, Jose
    Binder, Perry S.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2022, 48 (01): : 14 - 19
  • [8] Corneal aberrations measured with a high-resolution Scheimpflug tomographer: repeatability and reproducibility
    McAlinden, Colm
    Schwiegerling, Jim
    Khadka, Jyoti
    Pesudovs, Konrad
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (04): : 581 - 590
  • [9] Comparative evaluation of dual Scheimpflug imaging parameters in keratoconus, early keratoconus, and normal eyes
    Reddy, Jagadesh C.
    Rapuarto, Christopher J.
    Cater, Jacqueline R.
    Suri, Kunal
    Nagra, Parveen K.
    Hammersmith, Kristin M.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (04): : 582 - 592
  • [10] Clinical Comparison of Corneal Topography Using a Combined Scheimpflug and Placido (Galilei) and a Scheimpflug Device (Pentacam) in Keratoconus Eyes
    Tappeiner, C.
    Eschmann, R.
    Schuerch, K.
    Frueh, B. E.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)