Radiometric calibration algorithm for high dynamic range infrared imaging system

被引:2
|
作者
Yang, Guoqing [1 ]
Yu, Yi [1 ]
Sun, Zhiyuan [1 ]
Li, Zhou [1 ]
Pang, Xinyu [1 ,2 ]
Zhang, Tao [1 ]
机构
[1] Chinese Acad Sci, Changchun Inst Opt, Fine Mech & Phys, Changchun 130033, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
Radiometric calibration; High dynamic range imaging; Radiometry; Infrared radiation transmission and conversion; AMBIENT-TEMPERATURE; BLACKBODY; GAIN;
D O I
10.1016/j.infrared.2023.104607
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The infrared imaging system with high dynamic range is one of the most prime candidates in the area of quantitative infrared radiometry and thermometry applications. As the foundation of the measurement processes, radiometric calibration is the inception procedure which will be studied emphatically in this paper. Conventional radiometric calibration algorithm is not suitable for high dynamic range infrared imaging systems that requires the flexibility of adjusting the integration time and transmittance according to characteristics of the detected target. Unfortunately, fixed calibration coefficients will inevitably arouse the deterioration of the calibration accuracy in the case of variable integration time or the transmittance. For the purpose of solving above issues, effects of integration time and transmittance on calibration are analyzed in detail. A modified calibration algorithm considering the integration time and transmittance is proposed to compensate the calibration error caused by the change of these two factors. Experiments confirm that the accuracy of the proposed calibration algorithm can reach about 1 % under the conditions of varying integration time and transmittance, which is effectively applicable to high dynamic range infrared imaging applications.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] High dynamic range infrared thermography by pixelwise radiometric self calibration
    Ochs, M.
    Schulz, A.
    Bauer, H. -J.
    [J]. INFRARED PHYSICS & TECHNOLOGY, 2010, 53 (02) : 112 - 119
  • [2] Radiometric calibration method for large aperture infrared system with broad dynamic range
    Sun, Zhiyuan
    Chang, Songtao
    Zhu, Wei
    [J]. APPLIED OPTICS, 2015, 54 (15) : 4659 - 4666
  • [3] Global optimization radiometric calibration method for an infrared system with a wide dynamic range
    Li, Ting
    Lai, Xuefeng
    Li, Sujun
    Xia, Yucheng
    Zhou, Jinmei
    Liao, Sheng
    [J]. APPLIED OPTICS, 2024, 63 (02) : 406 - 414
  • [4] A design of an on-orbit radiometric calibration device for high dynamic range infrared remote sensors
    Sheng, Yicheng
    Jin, Weiqi
    Dun, Xiong
    Zhou, Feng
    Xiao, Si
    [J]. AOPC 2017: SPACE OPTICS AND EARTH IMAGING AND SPACE NAVIGATION, 2017, 10463
  • [5] An overview of the visible and infrared scanner radiometric calibration algorithm
    Barnes, RA
    Barnes, WL
    Lyu, CH
    Gales, JM
    [J]. JOURNAL OF ATMOSPHERIC AND OCEANIC TECHNOLOGY, 2000, 17 (04) : 395 - 405
  • [6] Research on radiometric calibration for super wide-angle staring infrared imaging system
    Huang, Fuyu
    Shen, Xueju
    Liu, Jie
    Li, Gang
    Ying, Jiaju
    [J]. INFRARED PHYSICS & TECHNOLOGY, 2013, 61 : 9 - 13
  • [7] High Dynamic Range Infrared Imaging for Moving Objects
    Kayikci, Umut
    Oduncu, Emrah
    Sivasligil, Mustafa
    Aytac, Berat
    [J]. 2018 26TH SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS CONFERENCE (SIU), 2018,
  • [8] Radiometric Calibration Method of Large Military Infrared Imaging Simulator
    Yang Sen
    Zhang Houqing
    [J]. ACTA OPTICA SINICA, 2021, 41 (24)
  • [9] Working Principle of the Calibration Algorithm for High Dynamic Range Solar Imaging with the Square Kilometre Array Precursor
    Kansabanik, Devojyoti
    [J]. SOLAR PHYSICS, 2022, 297 (09)
  • [10] Working Principle of the Calibration Algorithm for High Dynamic Range Solar Imaging with the Square Kilometre Array Precursor
    Devojyoti Kansabanik
    [J]. Solar Physics, 2022, 297