Performance evaluation of a single microchannel plate with large length-to-diameter ratio

被引:1
|
作者
Yan, Baojun [1 ,2 ]
Liu, Shulin [1 ,2 ,3 ]
Zhang, Binting [1 ,2 ]
Peng, Huaxing [1 ,2 ]
机构
[1] Chinese Acad Sci, Inst High Energy Phys, Beijing 100049, Peoples R China
[2] State Key Lab Particle Detect & Elect, Beijing 100049, Peoples R China
[3] Univ Chinese Acad Sci, Sch Nucl Sci & Technol, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
Electron multipliers (vacuum); Photon detectors for UV; visible and IR photons (vacuum) (photomultipliers; HPDs; others);
D O I
10.1088/1748-0221/18/12/P12011
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The conventional microchannel plate (MCP) detector has found widespread application in various fields. This article focuses on investigating the performance of a single MCP with a large length-to-diameter ratio (L/D) of 80:1, particularly for single electron counting. To enhance MCP performance, alumina with a high secondary electron yield (SEY) is coated onto the MCP using atomic layer deposition (ALD). The SEYs of alumina thin films with different thicknesses are measured using a pulsing electron beam method. The 80:1 L/D MCPs operate in electron counting mode, and the optimal alumina thickness is determined through a comparative study of MCP performance before and after coating. The relationships between maximum SEY, primary electron energy, gain, peak-to-valley ratio (P/V), and pulse height resolution (PHR) are analyzed. After alumina coating, the single 80:1 MCP exhibits improved gain, P/V and PHR. The optimal P/V and PHR of a single MCP as functions of the primary electron energy align with the relationship between the SEY of the alumina coating and the primary electron energy. Additionally, the variation of DC gain with extracted charge is investigated. This article provides valuable insights for parameter selection in achieving the optimal working state of MCP and explores the potential application of single electron counting using a single MCP.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] A high-performance magnetic shield with large length-to-diameter ratio
    Dickerson, Susannah
    Hogan, Jason M.
    Johnson, David M. S.
    Kovachy, Tim
    Sugarbaker, Alex
    Chiow, Sheng-wey
    Kasevich, Mark A.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (06):
  • [2] MIXING OF FLUIDS IN TANKS OF LARGE LENGTH-TO-DIAMETER RATIO BY RECIRCULATION
    HARRELL, JE
    PERONA, JJ
    INDUSTRIAL & ENGINEERING CHEMISTRY PROCESS DESIGN AND DEVELOPMENT, 1968, 7 (03): : 464 - &
  • [3] MEASUREMENT OF LENGTH-TO-DIAMETER RATIO OF SHORT SNIPPETS OF WOOL
    STEARN, AE
    TEXTILE INSTITUTE AND INDUSTRY, 1972, 10 (08): : 223 - &
  • [5] The Effect of Different Length-to-Diameter Ratio of Charge in EFP Shaping
    Liu, Hang
    Gu, Hongqiang
    Shi, Quan
    Shi, Xianming
    Gu, Chuang
    PROCEEDINGS OF 2013 INTERNATIONAL CONFERENCE ON QUALITY, RELIABILITY, RISK, MAINTENANCE, AND SAFETY ENGINEERING (QR2MSE), VOLS I-IV, 2013, : 2085 - 2087
  • [6] Analysis of aerodynamics characteristic of high length-to-diameter ratio missile
    Peng, Zhi Ling
    ADVANCES IN MATERIALS SCIENCE-BOOK, 2011, 327 : 153 - 158
  • [8] Large eddy simulation of axial and compound angle holes with varying hole length-to-diameter ratio
    Li, Weihong
    Shi, Wei
    Ii, Xueying
    Ren, Jing
    Jiang, Hongde
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2017, VOL 5A, 2017,
  • [9] Influence of length-to-diameter ratio on shrinkage of basalt fiber concrete
    Ma, Ruijie
    Yang, Jiansen
    Liu, Yuan
    Zheng, Xiaojun
    2017 3RD INTERNATIONAL CONFERENCE ON APPLIED MATERIALS AND MANUFACTURING TECHNOLOGY (ICAMMT 2017), 2017, 242
  • [10] EFFECT OF CORE LENGTH-TO-DIAMETER RATIO ON CONCRETE CORE STRENGTHS
    BARTLETT, FM
    MACGREGOR, JG
    ACI MATERIALS JOURNAL, 1994, 91 (04) : 339 - 348