Enhancing resolution of micro-CT images of reservoir rocks using super resolution

被引:13
|
作者
Zhao, Bochao [1 ]
Saxena, Nishank [1 ]
Hofmann, Ronny [1 ]
Pradhan, Chaitanya [1 ]
Hows, Amie [1 ]
机构
[1] Shell Int Explorat & Prod, 3333 Highway 6 S, Houston, TX 77082 USA
关键词
Modern imaging; Super resolution; Generative adversarial networks; BENCHMARKS; FLOW;
D O I
10.1016/j.cageo.2022.105265
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Current hardware configuration of micro-CT detectors puts a lower limit on voxel size that can be acquired while maintaining a sufficiently large field of view. This limits the degree to which rock pores can be resolved in a micro-CT image and thus restricting the application envelope of Digital Rock technology. Super resolution techniques can refine voxel size while maintaining a sufficiently large field of view using pairs of low-and high -resolution images for training. However, for interpretation of quality of Digital Rock results, image quality is not determined by voxel size alone but by the degree to which a feature such as pore throat is resolved, which depends on both the physical size of the feature and voxel size. Furthermore, artificially down-sampling finer voxel size images to obtain images of coarser voxel size for training deep learning networks is not sufficient to capture the mapping between images acquired at different resolutions. This is especially true for reservoir rocks because the noise and artifacts introduced during imaging and reconstruction are more complex than that captured by simple down-sampling operation. We overcome these two limitations, by (1) using the ratio of pore throat size and voxel size (N) to group training dataset instead of voxel size and (2) using pairs of registered micro-CT images acquired using a state-of-the-art detector instead of synthetically down-sampled images. We show that combination of these two techniques produced images with better sharpness and contrast and enabled us to refine voxel size significantly beyond what is possible using the current imaging technology while main-taining the field of view.
引用
下载
收藏
页数:15
相关论文
共 50 条
  • [1] A comparative analysis of super-resolution techniques for enhancing micro-CT images of carbonate rocks
    Soltanmohammadi, Ramin
    Faroughi, Salah A.
    APPLIED COMPUTING AND GEOSCIENCES, 2023, 20
  • [2] Monitoring plant growth using high resolution micro-CT images
    Paquit, Vincent C.
    Gleason, Shaun S.
    Kalluri, Udaya C.
    IMAGE PROCESSING: MACHINE VISION APPLICATIONS IV, 2011, 7877
  • [3] Optimizing Micro-CT Resolution for Geothermal Reservoir Characterization in the Pannonian Basin
    Njeru, Rita Mwendia
    Sofyan, Akhmad
    Halisch, Matthias
    Kobor, Balazs
    Szanyi, Janos
    ENERGIES, 2024, 17 (13)
  • [4] Processing of micro-CT images of granodiorite rock samples using convolutional neural networks (CNN). Part III: Enhancement of Scanco micro-CT images of granodiorite rocks using a 3D convolutional neural network super-resolution algorithm
    Roslin, A.
    Lebedev, M.
    Mitchell, T. R.
    Onederra, I. A.
    Leonardi, C. R.
    MINERALS ENGINEERING, 2023, 195
  • [5] Large-factor Micro-CT super-resolution of bone microstructure
    Yu, Hui
    Wang, Shuo
    Fan, Yinuo
    Wang, Guangpu
    Li, Jinqiu
    Liu, Chong
    Li, Zhigang
    Sun, Jinglai
    FRONTIERS IN PHYSICS, 2022, 10
  • [6] SR-CycleGAN: super-resolution of clinical CT to micro-CT level with multi-modality super-resolution loss
    Zheng, Tong
    Oda, Hirohisa
    Hayashi, Yuichiro
    Moriya, Takayasu
    Nakamura, Shota
    Mori, Masaki
    Takabatake, Hirotsugu
    Natori, Hiroshi
    Oda, Masahiro
    Mori, Kensaku
    JOURNAL OF MEDICAL IMAGING, 2022, 9 (02) : 24003
  • [7] High-resolution local imaging using a micro-CT
    Lee, Soo Yeol
    Cho, Min Hyoung
    Choi, Jeong Min
    2008 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1-4, 2008, : 137 - 140
  • [8] Spatial-resolution enhancement in micro-CT
    Pan, XC
    Yu, LF
    Kao, CM
    Pelizzari, C
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3244 - 3247
  • [9] Micro-CT at 10 micron spatial resolution
    Engelke, K
    Karolczak, M
    Seibert, U
    Lutz, A
    Kalender, WA
    OSTEOPOROSIS INTERNATIONAL, 2000, 11 : 9 - 9
  • [10] Measurement of spatial resolution of the micro-CT system
    Rong Jun-Yan
    Fu Guo-Tao
    Wei Cun-Feng
    Sun Cui-Li
    Wei Long
    CHINESE PHYSICS C, 2010, 34 (03) : 412 - 416