Thermodynamic analyses and performance improvement on a novel cascade-coupling-heating heat pump system for high efficiency hot water production

被引:17
|
作者
Xu, Yingjie [1 ,2 ,3 ]
Wang, Jiafeng [1 ,3 ]
Shen, Xi [1 ]
Sun, Zhe [1 ]
Wang, Xiaopo [2 ]
Han, Xiaohong [4 ]
机构
[1] Zhejiang Univ Technol, Coll Mech Engn, Engn Res Ctr Proc Equipment & Remfg, Minist Educ, Hangzhou 310014, Peoples R China
[2] Xi An Jiao Tong Univ, Key Lab Thermo Fluid Sci & Engn, Minist Educ, Xian 710049, Peoples R China
[3] Shengzhou Zhejiang Univ Technol, Inst Innovat Res, 388 Punan Rd, Shengzhou 312400, Zhejiang, Peoples R China
[4] Zhejiang Univ, Inst Refrigerat & Cryogen, State Key Lab Clean Energy Utilizat, Hangzhou 310027, Peoples R China
关键词
Heat pump; Energy saving; Cascade-coupling-heating; Water heater; High energy efficiency;
D O I
10.1016/j.enconman.2023.117448
中图分类号
O414.1 [热力学];
学科分类号
摘要
In the background of global warming and reducing carbon emission, air-source heat pump water heater is used as an energy efficient technology to improve the efficiency of building hot water production, which may account for 21-41% of building energy cost. However, there are still space for the energy efficiency improvement of heat pump water heater, as there is large temperature difference between water and refrigerant, which may limit the energy performance (especially at low ambient temperature) but receives little attention. Therefore, a novel cascade-coupling-heating heat pump system with less water-refrigerant temperature different is proposed in this paper, where part of the heat is first provided at the low-temperature stage, reducing the heat load at the hightemperature stage and the high-temperature stage compressor power, and increasing system energy efficiency. To study the system, a theoretical model was established and verified through experiments. Experimental and theoretical results show that: in the ambient temperature range of 243.15 K - 323.15 K, the average and maximum improvement in the coefficient of performance of the new system reach 34.8% and 107.7%, respectively, comparing with cascade heat pump; and in the ambient temperature range of 248.15 K - 323.15 K, when comparing with single-stage heat pump, the new system reveals average and maximum improvement in the coefficient of performance as high as 25.8% and 55.6%, respectively. This study provide a promising potential technology for efficiency water heating, and lay the basis for further study and application of the new system.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Impact of Compressor Drive System Efficiency on Air Source Heat Pump Performance for Heating Hot Water
    Szreder, Mariusz
    Miara, Marek
    SUSTAINABILITY, 2020, 12 (24) : 1 - 17
  • [2] Thermodynamic Analysis of a Cascade Heat Pump Incorporated in High-Temperature Heating System
    Rudonja, Nedzad
    Gojak, Milan
    Zlatanovic, Ivan
    Todorovic, Ruzica
    STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 2020, 66 (11): : 677 - 683
  • [3] A Study on the Performance of a Cascade Heat Pump for Generating Hot Water
    Boahen, Samuel
    Choi, Jong Min
    ENERGIES, 2019, 12 (22)
  • [4] Experimental characterization of the coupling and heating performance of a CO2 water-to-water heat pump and a water storage tank for domestic hot water production system
    Velasco, F. J. S.
    Haddouche, M. R.
    Illan-Gomez, F.
    Garcia-Cascales, J. R.
    ENERGY AND BUILDINGS, 2022, 265
  • [5] Development of two-stage compression and cascade heating heat pump system for hot water supply
    Hasegawa, H
    Saikawa, M
    Hashimoto, K
    Iwatsubo, T
    ASHRAE TRANSACTIONS 1996, VOL 102, PT 1, 1996, 102 : 248 - 256
  • [6] Development of two-stage compression and cascade heating heat pump system for hot water supply
    Central Research Inst of the, Electric Power Industry, Tokyo, Japan
    ASHRAE Trans, 1 (248-256):
  • [7] Detailed modeling of a novel photovoltaic thermal cascade heat pump domestic water heating system
    Fine, J. P.
    Friedman, J.
    Dworkin, S. B.
    RENEWABLE ENERGY, 2017, 101 : 500 - 513
  • [8] Computational and experimental performance analysis of a novel method for heating of domestic hot water with a ground source heat pump system
    Niemela, Tuomo
    Manner, Mika
    Laitinen, Ari
    Sivula, Timo-Mikael
    Jokisalo, Juha
    Kosonen, Risto
    ENERGY AND BUILDINGS, 2018, 161 : 22 - 40
  • [9] Development and Modification of CO2 Heat Pump Hot-water Space Heating System using Cascade Heat Pump Cycle
    Takayama, Yasunori
    Osagawa, Yasushi
    Honma, Takashi
    Ishikawa, Mitsuhiro
    Hasegawa, Hiromi
    Hashimoto, Katsumi
    Fujinawa, Takeshi
    12TH IIR GUSTAV LORENTZEN NATURAL WORKING FLUIDS CONFERENCE, 2016, : 689 - 696
  • [10] Performance investigation of a cascade heat pump water heating system with a quasi-steady state analysis
    Park, Hansaem
    Kim, Dong Ho
    Kim, Min Soo
    ENERGY, 2013, 63 : 283 - 294