Two-stage strategy in end-stage hip periprosthetic joint infection: utility of industrially prefabricated custom-made antibiotic spacers

被引:1
|
作者
Vicente, Matias [1 ,2 ,3 ]
Vilar, Inca [1 ]
Fraile Soriano, Rosa [2 ,4 ]
Capo, Irina [5 ]
Corona, Pablo S. [1 ,2 ,3 ]
机构
[1] Autonomous Univ Barcelona, Vall dHebron Univ Hosp, Orthopaed Surg Dept, Barcelona, Spain
[2] Vall dHebron Univ, Orthopaed Surg Dept, Sept & Reconstruct Surg Unit, Barcelona, Spain
[3] Vall dHebron Res Inst, Musculoskeletal Tissue Engn Grp, Barcelona, Spain
[4] Autonomous Univ Barcelona, Vall dHebron Univ Hosp, Surg Nurse Team, Barcelona, Spain
[5] Francesc de Borja Hosp, Orthopaed Surg Dept, Gandia, Spain
关键词
Bone defects; custom-made prefabricated spacers; hip joint infection; periprosthetic joint infection; two-stage revision arthroplasty; EXCHANGE ARTHROPLASTY; CEMENT SPACERS; REVISION; GENTAMICIN; VANCOMYCIN; SUCCESS;
D O I
10.1177/11207000221075356
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: Use of prefabricated mobile spacers in end-stage cases of hip periprosthetic joint infection (HPJI) is hindered when large bone defects exist. In such cases, prefabricated custom-made antibiotic spacers (P-CMAS) offer an alternative. Such spacers are individually designed according to the size and anatomical characteristics of the bone defect. The purpose of this study is to describe and evaluate the use of such patient-specific spacers in a two-stage strategy to treat end-stage HPJI cases, and to report on clinical outcomes. Methods: A retrospective study identified all patients with end-stage HPJIs from January 2015 through December 2019, treated using a P-CMAS. Primary outcome: infection eradication rate. Secondary outcomes: spacer-related complications and patient satisfaction. Minimum follow-up: 12 months after the second-stage surgery. Results: A total of 7 end-stage cases (mean of 6.7 previous surgical procedures) were included. Mean bone defect size was 191.57 (range 47-304) mm. Polymicrobial infection was detected in 42.86% of these cases. During the spacer stage there were no periprosthetic fractures, spacer dislocations or breakages, nor spacer-drug-related complications. All patients proceeded with the second stage uneventfully, with an average time between stages of 178 (range 119-326) days. In 5 cases a total femur arthroplasty was the reconstructive procedure performed. After a mean follow-up of 27.29 (range 14-49) months the infection was clinically eradicated in all patients, despite their difficult-to-treat scenarios. Conclusions: Industrially custom-made spacers offer an effective and safe option in performing 2-stage exchange arthroplasty in cases of end-stage HPJI with extensive bone defects.
引用
收藏
页码:697 / 704
页数:8
相关论文
共 50 条
  • [1] Mechanical complications and infection control comparison of custom-made and prefabricated articular hip spacers in the treatment of periprosthetic infection
    Emmer, Jan
    Tomas, Tomas
    Apostolopoulos, Vasileios
    Brancik, Pavel
    Rapi, Jakub
    Nachtnebl, Lubos
    JOINT DISEASES AND RELATED SURGERY, 2023, 34 (03): : 557 - 564
  • [2] New Technique for Custom-Made Spacers in Septic Two-Stage Revision of Total Hip Arthroplasties
    Mederake, Moritz
    Hofmann, Ulf Krister
    Fink, Bernd
    ANTIBIOTICS-BASEL, 2021, 10 (09):
  • [3] Viable bacteria persist on antibiotic spacers following two-stage revision for periprosthetic joint infection
    Ma, Dongzhu
    Shanks, Robert M. Q.
    Davis, Charles M., III
    Craft, David W.
    Wood, Thomas K.
    Hamlin, Brian R.
    Urish, Kenneth L.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2018, 36 (01) : 452 - 458
  • [4] Quality of life, infection control, and complication rates using a novel custom-made articulating hip spacer during two-stage revision for periprosthetic joint infection
    Andre Lunz
    Georg W. Omlor
    Gunter Schmidt
    Babak Moradi
    Burkhard Lehner
    Marcus R. Streit
    Archives of Orthopaedic and Trauma Surgery, 2022, 142 : 4041 - 4054
  • [5] Quality of life, infection control, and complication rates using a novel custom-made articulating hip spacer during two-stage revision for periprosthetic joint infection
    Lunz, Andre
    Omlor, Georg W.
    Schmidt, Gunter
    Moradi, Babak
    Lehner, Burkhard
    Streit, Marcus R.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2022, 142 (12) : 4041 - 4054
  • [6] Two-stage pricing for custom-made products
    Haruvy, Ernan E.
    Li, Tao
    Sethi, Suresh P.
    EUROPEAN JOURNAL OF OPERATIONAL RESEARCH, 2012, 219 (02) : 405 - 414
  • [7] Two-stage revision hip arthroplasty for infection with a custom-made, antibiotic-loaded, cement prosthesis as an interim spacer
    Hsieh, PH
    Chen, LH
    Chen, CH
    Lee, MS
    Yang, WE
    Shih, CH
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2004, 56 (06): : 1247 - 1252
  • [8] Clinical evaluation of a new technique for custom-made spacers in septic two-stage revision of total hip arthroplasties
    Mederake, Moritz
    Hofmann, Ulf Krister
    Fink, Bernd
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (08) : 5395 - 5403
  • [9] Clinical evaluation of a new technique for custom-made spacers in septic two-stage revision of total hip arthroplasties
    Moritz Mederake
    Ulf Krister Hofmann
    Bernd Fink
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 5395 - 5403
  • [10] Combinational Periprosthetic Hip Joint Infection and Fracture: A Two-Stage Revision with Long Femoral Stem Spacers
    Duong, T., V
    Duong, T. B.
    Tu, D.
    Quyen, N. Q. T.
    Tan, H.
    Hung, T. N. K.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2025, 19 (01) : 31 - 38