Determining the optimal reconstruction algorithm for FDG brain PET/CT images in BGO-based Whole body PET scanner

被引:0
|
作者
Asami, M. [1 ]
Ay, M. [1 ]
Farzanehfar, S. [2 ]
Ghafarian, P. [3 ]
Sheikhzadeh, P. [2 ]
机构
[1] Univ Tehran Med Sci, Dept Med Phys & Biomed Engn, Tehran, Iran
[2] Univ Tehran Med Sci, Imam Khomeini Hosp Complex, Dept Nucl Med, Tehran, Iran
[3] Shahid Beheshti Univ Med Sci, PET CT & Cyclotron Ctr, Masih Daneshvari Hosp, Tehran, Iran
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
EP-0712
引用
收藏
页码:S713 / S714
页数:2
相关论文
共 50 条
  • [1] Implementation of quadratic dose protocol for 18F-FDG whole-body PET imaging using a BGO-based PET/CT scanner, GE Discovery ST
    Musarudin, Marianie
    Selvam, Haniff Shazwan Muhammad Safwan
    Said, Mohamad Aminudin
    IRANIAN JOURNAL OF NUCLEAR MEDICINE, 2019, 27 (02): : 73 - 80
  • [2] Accuracy of 3D acquisition mode for myocardial FDG PET studies using a BGO-based scanner
    van der Weerdt, Arno P.
    Boellaard, Ronald
    Visser, Frans C.
    Lammertsma, Adriaan A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (09) : 1439 - 1446
  • [3] Accuracy of 3D acquisition mode for myocardial FDG PET studies using a BGO-based scanner
    Arno P. van der Weerdt
    Ronald Boellaard
    Frans C. Visser
    Adriaan A. Lammertsma
    European Journal of Nuclear Medicine and Molecular Imaging, 2007, 34 : 1439 - 1446
  • [4] Whole-body FDG PET and CT imaging of malignancies using a combined PET CT scanner.
    Charron, M
    Beyer, T
    Kinahan, PE
    Meltzer, CC
    Dachille, MA
    Townsend, DW
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 256P - 256P
  • [5] The effects of various penalty parameter values in Q.Clear algorithm for rectal cancer detection on 18F-FDG images using a BGO-based PET/CT scanner: a phantom and clinical study
    Sadeghi, Fatemeh
    Sheikhzadeh, Peyman
    Farzanehfar, Saeed
    Ghafarian, Pardis
    Moafpurian, Yalda
    Ay, Mohammadreza
    EJNMMI PHYSICS, 2023, 10 (01)
  • [6] The effects of various penalty parameter values in Q.Clear algorithm for rectal cancer detection on 18F-FDG images using a BGO-based PET/CT scanner: a phantom and clinical study
    Fatemeh Sadeghi
    Peyman Sheikhzadeh
    Saeed Farzanehfar
    Pardis Ghafarian
    Yalda Moafpurian
    Mohammadreza Ay
    EJNMMI Physics, 10
  • [7] Differences of FDG distribution between the whole body panel and dedicated brain panel in brain image of GEMINI PET/CT scanner
    Jeong, Y.
    Kang, D.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S316 - S317
  • [8] Adaptive Regularized Reconstruction Enabling High Resolution Brain PET Images from Whole Body FOV PET/CT Imaging
    Hsieh, Y.
    Binzel, K.
    Wright, C. L.
    Zhang, B.
    Maniawski, P.
    Knopp, M. V.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (SUPPL 1) : S488 - S488
  • [9] Optimization of reconstruction parameters for brain PET by silicon photomultiplier-based PET/CT scanner
    Matsubara, K.
    Sato, K.
    Ibaraki, M.
    Shinohara, Y.
    Kinoshita, T.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2019, 39 : 609 - 609
  • [10] The Usefulness of Whole Body FDG-PET/CT in Patients with Brain Metastasis
    Nakagawa, Kazuhiko
    Aoyagi, Masaru
    Inaji, Motoki
    Maehara, Taketoshi
    Toriyama, Hideyuki
    Kawano, Yoshihisa
    Tamaki, Masashi
    Nariai, Tadashi
    Ohno, Kikuo
    NEUROLOGICAL SURGERY, 2009, 37 (02): : 159 - 166