Fabrication of Mechanically Alloyed Super Duplex Stainless Steel Powder-Modified Carbon Paste Electrode for the Determination of Methylene Blue by the Cyclic Voltammetry Technique

被引:5
|
作者
Mahale, Rayappa Shrinivas [1 ,2 ]
Rajashekar, Vinaykumar [3 ]
Vasanth, Shamanth [1 ]
Chikkegowda, Sharath Peramenahalli [4 ]
Rajendrachari, Shashanka [5 ]
Mahesh, Vutukuru [6 ]
机构
[1] REVA Univ, Sch Mech Engn, Bengaluru 560064, Karnataka, India
[2] Jain Coll Engn & Res, Dept Mech Engn, Belagavi 590008, Karnataka, India
[3] Nitte Meenakshi Inst Technol, Dept Elect & Commun Engn, Bengaluru 560064, Karnataka, India
[4] JAIN Deemed Univ, Fac Engn & Technol, Dept Elect & Commun Engn, Bengaluru 562112, Karnataka, India
[5] BARTIN Univ, Dept Met & Mat Engn, TR-74100 Bartin, Turkiye
[6] SR Univ, Mech Engn Dept, Warangal 506371, Telangana, India
来源
ACS OMEGA | 2024年 / 9卷 / 09期
关键词
NANO-STRUCTURED DUPLEX; SILVER NANOPARTICLES; DYES;
D O I
10.1021/acsomega.3c09163
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Alloys with an equal balance of ferrite and austenite provide super duplex stainless steel (DSS) with enhanced strength and corrosion resistance. This study utilized mechanical alloying to produce nanostructured super duplex stainless steel powders for the identification of methylene blue dye in wastewater. High-energy particle grinding was employed to create the SAF-2507 DSS powders. To electrochemically oxidize methylene blue dye in wastewater, a modified carbon paste electrode (DSS-MCPE) was developed. Methylene blue, a water-soluble cationic colorant extensively used in the paper, pulp, and textile industries, poses a threat to human health and water supplies when improperly disposed of. DSS-MCPE demonstrated a significant current response, indicating its capability to detect methylene blue dye in a pH range of 6-8. The experiment revealed that 2 mg of DSS-MCPE produced a maximum current response of 72.22 mu A, facilitating the effective electrooxidation of methylene blue dye in wastewater. Furthermore, the investigation demonstrated that the active surface area of the 2 mg of DSS-MCPE (0.478 cm(2)) was greater than that of the bare carbon paste electrode (BCPE) (0.054 cm(2)). The increased active surface area was correlated with an enhanced current response. The strong interaction between methylene blue molecules at the interface of the produced 2 mg of DSS-MCPE contributed to the observed increase in anodic current across methylene blue concentrations ranging from 0.1 to 0.6 mM.
引用
收藏
页码:10660 / 10670
页数:11
相关论文
共 25 条
  • [1] Electrochemical oxidation of methylene blue dye in wastewater using mechanically alloyed high entropy alloy modified carbon paste electrode using cyclic voltammetry
    Rajendrachari, Shashanka
    Adimule, Vinayak M.
    Jayaprakash, Gururaj Kudur
    Pandith, Anup
    [J]. MATERIALS RESEARCH EXPRESS, 2023, 10 (05)
  • [2] Electrocatalytic Response of Duplex and Yittria Dispersed Duplex Stainless Steel Modified Carbon Paste Electrode in Detecting Folic Acid Using Cyclic Voltammetry
    Shashanka, R.
    Chaira, D.
    Swamy, B. E. Kumara
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (07): : 5586 - 5598
  • [3] Electrocatalytic determination of methyl orange dye using mechanically alloyed novel metallic glass modified carbon paste electrode by cyclic voltammetry
    Rajendrachari, Shashanka
    Basavegowda, Nagaraj
    Vinaykumar, R.
    Narsimhachary, Damanapeta
    Somu, Prathap
    Lee, Meng-Jen
    [J]. INORGANIC CHEMISTRY COMMUNICATIONS, 2023, 155
  • [4] Electrochemical Determination of Ascorbic Acid by Mechanically Alloyed Super Duplex Stainless Steel Powders
    Mahale, Rayappa Shrinivas
    Vasanth, Shamanth
    Chikkegouda, Sharath Peramenahalli
    Rajendrachari, Shashanka
    Narsimhachary, Damanapeta
    Basavegowda, Nagaraj
    [J]. METALS, 2023, 13 (08)
  • [5] Electrochemical Studies of Bromothymol Blue at surfactant Modified Carbon Paste Electrode By using Cyclic Voltammetry
    Chandrashekar, B. N.
    Swamy, B. E. Kumara
    Mahesh, K. R. Vishnu
    Chandra, Umesh
    Sherigara, B. S.
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2009, 4 (03): : 471 - 480
  • [6] Synthesis of CdO Nanoparticles and their Modified Carbon Paste Electrode for Determination of Dopamine and Ascorbic acid by using Cyclic Voltammetry Technique
    Reddy, Sathish
    Swamy, B. E. Kumara
    Chandra, Umesh
    Sherigara, B. S.
    Jayadevappa, H.
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2010, 5 (01): : 10 - 17
  • [7] Solid phase microextraction and determination of dichromate in aqueous solution based on pine needle powder-modified carbon paste electrode by potentiometry
    Dong, Guobin
    Zhu, Yongchun
    Tian, Hong
    Li, Fei
    Xin, Shigang
    Qin, Yan
    [J]. RESEARCH ON CHEMICAL INTERMEDIATES, 2015, 41 (02) : 1191 - 1201
  • [8] Solid phase microextraction and determination of dichromate in aqueous solution based on pine needle powder-modified carbon paste electrode by potentiometry
    Guobin Dong
    Yongchun Zhu
    Hong Tian
    Fei Li
    Shigang Xin
    Yan Qin
    [J]. Research on Chemical Intermediates, 2015, 41 : 1191 - 1201
  • [9] Sodium Dodecyl Sulfate Modified Carbon Nano Tube Paste Electrode for Sensitive Cyclic Voltammetry Determination of Isatin
    Monnappa, Amrutha Balliamada
    Manjunatha, Jamballi Gangadharappa
    Bhatt, Aarti Sripathi
    Malini, Kodi
    [J]. ADVANCED PHARMACEUTICAL BULLETIN, 2021, 11 (01) : 111 - 119
  • [10] Determination of Clobetasol Propionate by Multi-walled Carbon Nanotube-modified Carbon Paste Electrode using Cyclic Voltammetry
    Li, Ping
    Liu, Shuo
    Li, Kang
    HaiyunZhai
    Zhou, Qing
    Pan, Yufang
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (07): : 6737 - 6747