Numerical performance of a water source transcritical CO2 heat pump with mechanical subcooling

被引:7
|
作者
Illan-Gomez, Fernando [1 ]
Garcia-Cascales, Jose R. [1 ]
Velasco, F. J. S. [1 ]
Oton-Martinez, Ramon A. [2 ]
机构
[1] Univ Politecn Cartagena, ETSII, Dept Ingn Term & Fluidos, C Dr Fleming S-N, Murcia 30202, Spain
[2] Ctr Univ Def Acad Gen Aire, Dept Ingn & Tecn Aplicadas, C Lopez Pena S-N, Murcia 30720, Spain
关键词
Water heater; Transcritical cycle; Heat pump; CO2; DMS; IHX; OPTIMAL DISCHARGE PRESSURE; CARBON-DIOXIDE; HOT-WATER; REFRIGERATION CYCLES; COMBINED R134A; EXCHANGER; TEMPERATURE; SYSTEM; COMPRESSION; OPTIMIZATION;
D O I
10.1016/j.applthermaleng.2022.119639
中图分类号
O414.1 [热力学];
学科分类号
摘要
In order to improve their efficiency, transcritical CO2 heat pumps need to resort to the use of a subcooling method. Among the different subcooling methods, dedicated mechanical subcooling (DMS) systems and internal heat exchangers (IHX) are currently the more promising technologies. This paper presents a numerical study of a transcritical water source CO2 heat pump during hot water generation using different subcooling methods. Ten different configurations, including both, IHX and DMS, separately and combined in different layouts, some of them not studied previously, are analyzed numerically under the same operating conditions in order to compare their performance. A description of the numerical model is presented: compressors are modeled using the performance curves provided by their manufacturers, expansion valves are modeled as isenthalpic, and heat exchangers are modeled by deriving correlations for the evaporation/condensation pressure and heat transfer rate obtained using a 1D cell-by-cell discretization method previously applied to all heat exchangers. Results are presented for different water heating conditions and show that in most configurations analyzed, the use of a DMS does not improve the performance of the system compared to the base system with IHX. There is only an improvement in the efficiency for two of the configurations analyzed, those in which the main CO2 cycle and the DMS cycle are coupled by the water flowing first through the evaporator of the auxiliary cycle and then through the gas cooler of the main cycle. Specifically, compared to the base cycle with IHX, the configuration that provides the best results (Conf. F* according to the nomenclature used in this work) gives average improvements of around 26% in efficiency and almost 160% in the heating capacity, while the optimum gas cooler pressure is reduced by an average of 12%. Even more, compared to the best performance system previously studied by other authors (indirect DMS without IHX, Conf. F in this work) this configuration improves the efficiency by almost 8.5%, with a decrease in the total capacity lower than 1% and similar gas cooler pressure. The results also show that the auxiliary compressor capacity and the way in which the water is distributed among the main and the auxiliary cycle have an important influence on the efficiency of the system, although that influence depends on the configuration studied. For the configuration that provides the best efficiency (Conf. F*), the optimum efficiency is obtained when the auxiliary compressor capacity is similar to the capacity of the main compressor (55% of the total heating capacity comes from the auxiliary cycle), and the water is mostly heated in the auxiliary cycle (85% of the water flow heated in the condenser of the auxiliary cycle, 15% heated in the gas cooler of the main cycle).
引用
收藏
页数:17
相关论文
共 50 条
  • [1] A Modified Transcritical CO2 Heat Pump With Mechanical Subcooling for Heating
    He, Yu-Jia
    Cheng, Jia-Hao
    Chang, Meng-Meng
    Shao, Liang-Liang
    Zhang, Chun-Lu
    [J]. Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2021, 42 (11): : 2771 - 2774
  • [2] Analysis of performance of CO2 transcritical heat pump system with mechanical subcooling and ejector
    Dong, Liwei
    Li, Minxia
    Yao, Liang
    Ma, Yitai
    Zhan, Haomiao
    [J]. Huagong Jinzhan/Chemical Industry and Engineering Progress, 2021, 40 (10): : 5431 - 5440
  • [3] Evaluation of the Use of Different Dedicated Mechanical Subcooling (DMS) Strategies in a Water Source Transcritical CO2 Heat Pump for Space Heating Applications
    Illan-Gomez, Fernando
    Ramon Garcia-Cascales, Jose
    Javier Sanchez-Velasco, Francisco
    Oton-Martinez, Ramon A.
    [J]. CLEAN TECHNOLOGIES, 2022, 4 (04): : 1208 - 1226
  • [5] The Influence of Internal Heat Exchanger on the Performance of Transcritical CO2 Water Source Heat Pump Water Heater
    Feng, Fan
    Zhang, Ze
    Liu, Xiufang
    Liu, Changhai
    Hou, Yu
    [J]. ENERGIES, 2020, 13 (07)
  • [6] Subcooling effect on the optimal performance for a transcritical CO2 heat pump with cold thermal energy storage
    Wang, Ji
    Evans, Michael
    Belusko, Martin
    Zhao, Chunrong
    Liu, Ming
    Bruno, Frank
    [J]. HEAT AND MASS TRANSFER, 2023, 59 (07) : 1257 - 1275
  • [7] Subcooling effect on the optimal performance for a transcritical CO2 heat pump with cold thermal energy storage
    Ji Wang
    Michael Evans
    Martin Belusko
    Chunrong Zhao
    Ming Liu
    Frank Bruno
    [J]. Heat and Mass Transfer, 2023, 59 : 1257 - 1275
  • [8] Performance of a transcritical CO2 heat pump for simultaneous water cooling and heating
    Sarkar, J.
    Bhattacharyya, Souvik
    Ramgopal, M.
    [J]. World Academy of Science, Engineering and Technology, 2010, 68 : 128 - 134
  • [9] Performance of a Transcritical CO2 Heat Pump for Simultaneous Water Cooling and Heating
    Sarkar, J.
    Bhattacharyya, Souvik
    Gopal, M. Ram
    [J]. ASHRAE TRANSACTIONS 2010, VOL 116, PT 1, 2010, 116 : 534 - +
  • [10] Experimental evaluation of transcritical CO2 refrigeration with mechanical subcooling
    Bush, John
    Beshr, Mohamed
    Aute, Vikrant
    Radermacher, Reinhard
    [J]. SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2017, 23 (06) : 1013 - 1025