Transfer Functions for RF Partial Discharge Signals in Power Cable Joints

被引:4
|
作者
Yang, Shaocai [1 ]
Du, Qing [1 ]
Hu, Xiao [1 ,2 ,3 ]
机构
[1] Guizhou Univ, Guiyang 550025, Peoples R China
[2] Zhejiang Univ, Hangzhou 310027, Peoples R China
[3] Zhejiang Horizon Instrument Transformer Co Ltd, Jiangshan 324100, Peoples R China
关键词
Power cables; Time-domain analysis; Finite difference methods; Cable shielding; Insulation; Copper; Solid modeling; Finite-difference time-domain (FDTD); transfer functions (TF); radio frequency (RF); partial discharge (PD); cable joint; PROPAGATION CHARACTERISTICS; MODEL; WAVE;
D O I
10.1109/TPWRD.2022.3220274
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Inappropriate manufacturing of cable joints can cause defects in the joint insulation. During operation, partial discharge (PD) may occur at these defects. The development of PD can cause accelerated aging even breakdown of the insulation, resulting in faults in the electric grid. In this paper, for radio frequency (RF) detection of PD in cable joints, a finite-difference time-domain (FDTD) model of a 35 kV XLPE cable joint is established, an excitation source is defined in the model to represent PD of different defects, and then propagation characteristics of RF electromagnetic signals induced by PD in cable joints are studied through the established model. Transfer functions (TF) of RF PD signals obtained with the FDTD model show that both magnitude and shape of the TF are closely related to the location and direction of the excitation source in the model. Two peaks in the magnitude, locating at 380 MHz and 790 MHz, respectively are present in the obtained TF regardless of the excitation source settings. Moreover, the TF magnitude for the excitation source defined in the radial direction of the cable joint model is found to be generally more than one order larger than that of the same source defined in the axial direction. The effectiveness of the FDTD model in representing high frequency properties of the cable joint has been checked against both time domain reflectometry (TDR) and S-21 measurements on a cable joint made in laboratory. The TF results from this work are expected to be helpful for applications of radiometric PD detection to cable joints, e.g., enabling improvement of the detection sensitivity through optimizing frequency responses of RF sensors.
引用
收藏
页码:1649 / 1655
页数:7
相关论文
共 50 条
  • [1] Detection and localization of partial discharge in high voltage power cable joints
    Kheirmand, A
    Leijon, M
    Tornkvist, C
    [J]. PROCEEDINGS OF THE 1998 IEEE INTERNATIONAL CONFERENCE ON CONDUCTION AND BREAKDOWN IN SOLID DIELECTRICS - ICSD '98, 1998, : 145 - 148
  • [2] Radio-Frequency Detection of Partial Discharge in Power Cable Joints
    Hu, Xiao
    Yang, Shaocai
    Du, Qing
    Chen, Xiangrong
    Tang, Fuxin
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2024, 39 (01) : 317 - 324
  • [3] Analysis of Partial Discharge in Underground Cable Joints
    Rajalakshmi, B.
    Kalaivani, L.
    [J]. 2015 INTERNATIONAL CONFERENCE ON INNOVATIONS IN INFORMATION, EMBEDDED AND COMMUNICATION SYSTEMS (ICIIECS), 2015,
  • [4] Time-frequency Analysis of RF Signals From Internal Discharge of XLPE Cable Joints
    Du, Qing
    Yang, Shaocai
    Hu, Xiao
    [J]. Dianwang Jishu/Power System Technology, 2023, 47 (12): : 5266 - 5272
  • [5] Investigation on Partial Discharge Activity inside the Cable Accessories due to Improper Installation of Power Cable Joints
    Batalovic, Mirza
    Matoruga, Halid
    Berberovic, Sead
    Matoruga, Mirza
    [J]. PROCEEDINGS OF 18TH INTERNATIONAL CONFERENCE ON SMART TECHNOLOGIES (IEEE EUROCON 2019), 2019,
  • [6] Effect of energizing voltage frequency on partial discharge characteristics of defects in power cable joints
    Wang, Li
    Jin, Lei
    Li, Hongjie
    [J]. ENERGY REPORTS, 2023, 9 : 518 - 524
  • [7] Effect of energizing voltage frequency on partial discharge characteristics of defects in power cable joints
    Wang, Li
    Jin, Lei
    Li, Hongjie
    [J]. ENERGY REPORTS, 2023, 9 : 518 - 524
  • [8] Effect of energizing voltage frequency on partial discharge characteristics of defects in power cable joints
    Wang, Li
    Jin, Lei
    Li, Hongjie
    [J]. ENERGY REPORTS, 2023, 9 : 518 - 524
  • [9] Partial Discharge Measurement for Cable Terminators of XLPE Power Cable
    Apiratikul, P.
    Boonchiam, P.
    Plangklang, B.
    Suwanasri, T.
    [J]. 2007 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, VOLS 1 AND 2, 2007, : 573 - 576
  • [10] Partial Discharge Distributed Locating in Power Cable Joints Using Φ-OTDR Optical Fiber System
    Liu, Zhiheng
    Yang, Sen
    Chen, Qian
    Liu, Zhibin
    Zhang, Zhaoyan
    Li, Ze
    Meng, Xiaokai
    [J]. IEEE SENSORS JOURNAL, 2024, 24 (09) : 14404 - 14412