Objective cataract grading methods and expected contrast sensitivity reestablishment with multifocal intraocular lenses

被引:2
|
作者
Fernandez, Joaquin [1 ]
Burguera, Noemi [1 ]
Rocha-de-Lossada, Carlos [1 ,2 ,3 ]
Rachwani-Anil, Rahul [4 ]
Rodriguez-Vallejo, Manuel [1 ]
机构
[1] VITHAS Almeria Hosp, Dept Ophthalmol, Qvis, Almeria 04120, Spain
[2] Hosp Reg Univ Malaga, Plaza Hosp Civil S-N, Malaga 29009, Spain
[3] Univ Seville, Dept Cirugia, Area Oftalmol,Doctor Fedriani S-N, Seville 41009, Spain
[4] Hosp Norte Malaga, Ave Poeta Munoz Rojas S-N, Malaga 29200, Antequera, Spain
关键词
Multifocal intraocular lens; Screening; Contrast sensitivity; Defocus curves; VISUAL-ACUITY; EXCHANGE; SATISFACTION;
D O I
10.1007/s10792-023-02680-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo determine the cut-off points for age and metrics provided by cataract grading objective systems for which a reestablishment in contrast sensitivity (CS) is expected after multifocal intraocular lens (MIOL) implantation.MethodsOne hundred seven subjects were included in this retrospective analysis carried out during the screening for presbyopia and cataract surgery. Monocular distance corrected contrast sensitivity defocus curve (CSDC) and visual acuity were measured, and crystalline lens sclerosis was graded with three objective metrics: Ocular Scatter Index (OSI), Dysfunctional Lens Index (DLI) and Pentacam Nucleus Staging (PNS). A CS value of 0.8 logCS at far distance, following published literature on this matter, was selected to compute the cut-off that maximized the detection of eyes exceeding this value at the preoperative screening, either for age or objective metrics.ResultsThe CDCS showed a stronger correlation than CDVA with objective grading methods, whereas all objective metrics were significantly correlated between them (p < 0.05). The cut-offs for age, OSI, DLI and PNS were <= 62, <= 1.25, >= 7.67 and <= 1, respectively. The OSI provided the highest area under the receiver operating characteristic curve (0.85) followed by the age (0.84), DLI (0.74) and PNS (0.63).ConclusionsSurgeons conducting clear lens exchange should communicate the possible distance CS loss after surgery with MIOL implantation according to the previous described cut-offs points. Age in combination with any cataract grading objective system is recommended to detect possible inconsistencies.
引用
收藏
页码:2825 / 2832
页数:8
相关论文
共 50 条
  • [1] Objective cataract grading methods and expected contrast sensitivity reestablishment with multifocal intraocular lenses
    Joaquín Fernández
    Noemí Burguera
    Carlos Rocha-de-Lossada
    Rahul Rachwani-Anil
    Manuel Rodríguez-Vallejo
    [J]. International Ophthalmology, 2023, 43 : 2825 - 2832
  • [2] CONTRAST SENSITIVITY IN MULTIFOCAL INTRAOCULAR LENSES
    RAVALICO, G
    BACCARA, F
    RINALDI, G
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (01): : 22 - 25
  • [3] A COMPARISON OF CONTRAST SENSITIVITY TEST METHODS FOR MULTIFOCAL INTRAOCULAR LENSES
    ODONOGHUE, E
    KELLY, S
    NACER, M
    STOREY, J
    MURRAY, I
    MCLEOD, D
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1991, 32 (04) : 1281 - 1281
  • [4] Pattern ERG as an Objective Outcome Measure of Contrast Sensitivity in Patients with Multifocal Intraocular Lenses
    Tian, Jack
    Garcia, Martin
    Sadun, Alfredo A.
    Coupland, Stuart G.
    Karanjia, Rustum
    Lu, Kenneth
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [5] CONTRAST SENSITIVITY THROUGH MULTIFOCAL AND MONOFOCAL INTRAOCULAR LENSES
    AKUTSU, H
    LEGGE, GE
    SHOWALTER, M
    KIRBY, VM
    LINDSTROM, RL
    ZABEL, RW
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1991, 32 (04) : 799 - 799
  • [6] CONTRAST SENSITIVITY AND READING THROUGH MULTIFOCAL INTRAOCULAR LENSES
    AKUTSU, H
    LEGGE, GE
    SHOWALTER, M
    LINDSTROM, RL
    ZABEL, RW
    KIRBY, VM
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1992, 110 (08) : 1076 - 1080
  • [7] Tritan colour contrast sensitivity function in refractive multifocal intraocular lenses
    Pieh, S
    Hanselmayer, G
    Lackner, B
    Marvan, P
    Grechenig, A
    Weghaupt, H
    Vass, C
    Skorpik, C
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (07) : 811 - 815
  • [8] Contrast sensitivity and glare disability with diffractive and refractive multifocal intraocular lenses
    Pieh, S
    Weghaupt, H
    Skorpik, C
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (05): : 659 - 662
  • [9] Multifocal intraocular lenses for unilateral cataract in children
    Cristobal, Jose A.
    Remon, Leon
    Angeles Del Buey, Maria
    Montes-Mico, Robert
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (12): : 2035 - 2040
  • [10] Contrast acuity and contrast sensitivity after binocular implantation of multifocal or monofocal intraocular lenses
    Breitkopf, J
    Eisenmann, D
    Jacobi, FK
    [J]. OPHTHALMOLOGE, 1997, 94 (07): : 519 - 522