Comparison of two types of visual quality analyzer for the measurement of high order aberrations

被引:0
|
作者
Jing Hao [1 ,2 ]
Lin Li [3 ]
Fang Tian [1 ]
Hong Zhang [1 ]
机构
[1] Department of Cataract, Tianjin Medical University Eye Hospital
[2] North China University of Science and Technology
[3] Tangshan Gongren Hospital
关键词
KR-1W; iTrace; high order aberration; difference; agreement;
D O I
暂无
中图分类号
R770.4 [眼科诊断学];
学科分类号
100212 ;
摘要
AIM: To compare the difference and agreement of KR-1W and i Trace for measurement of high order aberrations.·METHODS: KR-1W and i Trace were respectively used in a group of healthy people(40 volunteers, 32 eyes) to measure the high order aberration(HOA) of corneal,internal and total ocular. The clinical difference and agreement of two instruments were respectively evaluated by paired-samples t-test and Bland-Altman analysis.·RESULTS: The paired-samples t-test showed that the corneal HOA measured by the two instruments had no statistical differences(P >0.05); but the internal and total ocular HOA had significant statistical differences(P <0.05), and the mean results measured by i Trace were higher than that of KR-1W. However, Bland-Altman analysis revealed that the HOA of corneal and internal were all in 95% limits of agreement; and just one point of total ocular HOA was beyond the 95% limits of agreement.·CONCLUSION: KR-1W and i Trace were consistent well in the measurement of corneal, internal and total ocular HOA, especially for the cornea.
引用
收藏
页码:292 / 297
页数:6
相关论文
共 50 条
  • [1] Comparison of two types of visual quality analyzer for the measurement of high order aberrations
    Hao, Jing
    Li, Lin
    Tian, Fang
    Zhang, Hong
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2016, 9 (02) : 292 - 297
  • [2] SUBJECTIVE MEASUREMENT OF HIGH-ORDER ABERRATIONS OF EYE
    HOWLAND, B
    HOWLAND, HC
    SCIENCE, 1976, 193 (4253) : 580 - 582
  • [3] Influence of Angle κ and Higher-Order Aberrations on Visual Quality Employing Two Diffractive Trifocal IOLs
    Velasco-Barona, Cecilio
    Corredor-Ortega, Claudia
    Mendez-Leon, Alejandra
    Casillas-Chavarin, Nadia L.
    Valdepena-Lopez Velarde, Daniel
    Cervantes-Coste, Guadalupe
    Malacara-Hernandez, Daniel
    Gonzalez-Salinas, Roberto
    JOURNAL OF OPHTHALMOLOGY, 2019, 2019
  • [4] Comparison of the wavefront aberrations for two different types of cataract surgeries
    Ma, L
    Zhang, J
    Liu, C
    He, J
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U76 - U76
  • [5] The measurement of high-order aberrations of human eyes and it's influence on retinal image quality
    Quan, W
    Ling, N
    Wang, ZQ
    Mu, GG
    ISTM/2003: 5TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-6, CONFERENCE PROCEEDINGS, 2003, : 2075 - 2078
  • [7] Comparison of two psychophysical methods for image color quality measurement: Paired comparison and rank order
    Cui, CW
    EIGHTH COLOR IMAGING CONFERENCE: COLOR SCIENCE AND ENGINEERING SYSTEMS, TECHNOLOGIES, APPLICATIONS, 2000, : 222 - 227
  • [8] Changes in visual acuity and high-order aberrations after SMILE
    Noel Jaurrieta-Hinojos, Jesus
    Fernandez, Oscar
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [9] Pinhole Pupilloplasty for Higher Order Aberrations: Assessment of Visual Quality and Depth of Focus
    Narang, Priya
    Holladay, Jack
    Agarwal, Amar
    Gracy, Helen
    Kumar, Dhivya Ashok
    Sivagnanam, Soundari
    JOURNAL OF REFRACTIVE SURGERY, 2020, 36 (12) : 812 - +
  • [10] COMPARISON OF THE OCULOKINETIC PERIMETRY GLAUCOMA SCREENER WITH 2 TYPES OF VISUAL-FIELD ANALYZER
    GREVE, M
    CHISHOLM, IA
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 1993, 28 (05): : 201 - 206