Sensitivity Analysis of Relap5 Simulation on AP1000 Nuclear Power Plant

被引:0
|
作者
谢明亮 [1 ]
谢飞 [1 ]
单福昌 [1 ]
谢政权 [1 ]
机构
[1] China Nuclear Power Operation Technology Corporation,Ltd.
关键词
sensitivity analysis; RELAP5; AP1000; nodalization;
D O I
10.19884/j.1672-5220.2018.01.018
中图分类号
TM623 [核电厂(核电站)];
学科分类号
080802 ;
摘要
During the simulation of AP1000 nuclear power plant,the values of input parameters, core nodalization methods and calculation models, may have important influence on the code outputs. Therefore, it is necessary to identify and evaluate the influence of these parameters and modeling approaches quantitatively. Based on the best estimate thermal-hydraulic system code RELAP5,sensitivity analyses have been performed on core partition methods,parameters and models in AP1000 nuclear power plant,such as the core channel number,pressurizer node number,and feedwater temperature. The results show that code channel number,code channel node number, and the pressurizer node number have apparent influences on the coolant temperature variation and pressure drop in the reactor. The feedwater temperature is a sensitive factor to the steam generator( SG) outlet temperature and the SG outlet pressure. In addition,the influence of the cross-flow model on coolant temperature variation and pressure drop through the reactor is insignificant,both in steady state and loss of power transient. Furthermore, some suitable parameters and modes also have been put forward for the nuclear system simulation.
引用
收藏
页码:94 / 100
页数:7
相关论文
共 50 条
  • [1] VERIFICATION OF THE AP1000 NUCLEAR POWER PLANT SIMULATOR NPPSIM AGAINST RELAP5 FOR TRANSIENT ANALYSIS
    Wu, Shifa
    Wang, Pengfei
    Fang, Huawei
    Wei, Xinyu
    Zhao, Fuyu
    [J]. PROCEEDINGS OF THE 24TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2016, VOL 5, 2016,
  • [2] THE AP1000 LBLOCA ANALYSIS USING SCDAP/RELAP5
    Xie, Heng
    [J]. PROCEEDINGS OF THE 22ND INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2014, VOL 3, 2014,
  • [3] Calculations for AP1000 nuclear power plant SGTR accident based on RELAP5/mod 3.3 program
    Jia, Bin
    Jing, Jianping
    Qiao, Xuedong
    Zhang, Chunming
    [J]. JOURNAL OF COMPUTATIONAL METHODS IN SCIENCES AND ENGINEERING, 2015, 15 (01) : 81 - 90
  • [4] The SCDAP/RELAP5 3.2 model of AP1000 on SBLOCA
    Xie, Heng
    He, Shuangji
    [J]. PROGRESS IN NUCLEAR ENERGY, 2012, 61 : 102 - 107
  • [5] LOCA SIMULATIONS OF AP1000 WITH DIFFERENT BREAKS BASED ON RELAP5
    Hou, Xiuqun
    Xie, Danmei
    Cai, Lin
    Zhang, Peng
    Tan, Jie
    [J]. PROCEEDINGS OF THE 24TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2016, VOL 3, 2016,
  • [6] RELAP5模拟AP1000 ERVC自然循环过程研究
    崔成鑫
    陈炼
    胡啸
    [J]. 核科学与工程, 2016, 36 (01) : 48 - 55
  • [7] Lumped parameter method application in nuclear engineering - AP1000 DVI line break accident analysis by RELAP5
    Qiao, Xue-Dong
    Jing, Jian-Ping
    An, Jie-Ru
    Sun, Wei
    Jia, Bin
    Li, Yuan-Shan
    Bi, Jin-Sheng
    Zhuang, Shao-Xin
    Zhang, Chun-Ming
    [J]. JOURNAL OF COMPUTATIONAL METHODS IN SCIENCES AND ENGINEERING, 2015, 15 (01) : 63 - 71
  • [8] RELAP5模拟AP1000 ERVC自然循环过程研究
    崔成鑫
    陈炼
    胡啸
    [J]. 核科学与工程, 2016, 36 (02) : 165 - 171
  • [9] AP1000 station blackout study with and without depressurization using RELAP5/SCDAPSIM
    Trivedi, A. K.
    Allison, C.
    Khanna, A.
    Munshi, P.
    [J]. NUCLEAR ENGINEERING AND DESIGN, 2016, 307 : 299 - 308
  • [10] Research of complete loss of flow accident for AP1000 based on RELAP5 code
    Jing, Jianping
    Sun, Wei
    Huang, Xuyang
    Qiao, Xuedong
    [J]. JOURNAL OF COMPUTATIONAL METHODS IN SCIENCES AND ENGINEERING, 2015, 15 (02) : 229 - 239