An analytical simulation technique for cone-beam CT and pinhole SPECT

被引:0
|
作者
ZHANG Xuezhu QI Yujin~* Shanghai Institute of Applied Physics
机构
基金
中国国家自然科学基金;
关键词
Computer simulation; Mathematical Phantom; Cone-beam CT; Pinhole SPECT;
D O I
10.13538/j.1001-8042/nst.22.338-343
中图分类号
TP391.41 [];
学科分类号
080203 ;
摘要
This study was aimed at developing an efficient simulation technique with an ordinary PC.The work involved derivation of mathematical operators,analytic phantom generations,and effective analytical projectors developing for cone-beam CT and pinhole SPECT imaging.The computer simulations based on the analytical projectors were developed by ray-tracing method for cone-beam CT and voxel-driven method for pinhole SPECT of degrading blurring.The 3D Shepp-Logan,Jaszczak and Defrise phantoms were used for simulation evaluations and image reconstructions.The reconstructed phantom images were of good accuracy with the phantoms.The results showed that the analytical simulation technique is an efficient tool for studying cone-beam CT and pinhole SPECT imaging.
引用
收藏
页码:338 / 343
页数:6
相关论文
共 50 条
  • [1] An analytical simulation technique for cone-beam CT and pinhole SPECT
    Zhang Xuezhu
    Qi Yujin
    [J]. NUCLEAR SCIENCE AND TECHNIQUES, 2011, 22 (06) : 338 - 343
  • [2] Pinhole SPECT vs. cone-beam SPECT
    Zeng, Gengsheng L.
    [J]. MEDICAL BIOMETRICS, PROCEEDINGS, 2007, 4901 : 240 - 247
  • [3] CLINICAL CONE-BEAM SPECT
    BICE, AN
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (01) : 141 - 142
  • [4] Lag correction for flat-panel cone-beam CT in SPECT/CT
    Wang, Jiong
    Hansis, Eberhard
    van de Haar, Peter
    Sowards-Emmerd, David
    Bredno, Joerg
    Shao, Lingxiong
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [5] Analytical geometric parameter calibration algorithm for cone-beam CT
    Chen, Lian
    Wu, Zhifang
    Liu, Ximing
    Yao, Ming
    [J]. Qinghua Daxue Xuebao/Journal of Tsinghua University, 2010, 50 (03): : 418 - 421
  • [6] CONE-BEAM SPECT WITH A TILTED DETECTOR
    GRANGEAT, P
    GUILLEMAUD, R
    RIZO, P
    SAUZE, R
    DONNER, Q
    GORIUS, JP
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1993, 17 (4-5) : 279 - 287
  • [7] Cone-beam tomography from 12 pinhole vertices
    Clackdoyle, R
    Noo, F
    [J]. 2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1874 - 1876
  • [8] Analytical fan-beam and cone-beam reconstruction algorithms with uniform attenuation correction for SPECT
    Tang, QL
    Zeng, GSL
    Gullberg, GT
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (13): : 3153 - 3170
  • [9] Dedicated scanner for laboratory investigations on cone-beam CT/SPECT imaging of the breast
    Mettivier, Giovanni
    Russo, Paolo
    Cesarelli, Mario
    Ospizio, Roberto
    Passeggio, Giuseppe
    Roscilli, Lorenzo
    Pontoriere, Giuseppe
    Rocco, Raffaele
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 629 (01): : 350 - 356
  • [10] Development of optimized cone-beam brain SPECT
    Krol, A.
    Vogelsang, L.
    Ye, H.
    Feiglin, D. H.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S175 - S175