In vitro corrosion-fatigue behavior of biodegradable Mg/HA composite in simulated body fluid

被引:0
|
作者
E.Ghazizadeh [1 ]
A.H.Jabbari [1 ]
M.Sedighi [1 ]
机构
[1] School of Mechanical Engineering, Iran University of Science and Technology
关键词
D O I
暂无
中图分类号
TB333 [金属-非金属复合材料]; TB304 [材料腐蚀与保护];
学科分类号
0805 ; 080502 ;
摘要
Magnesium and its composites as biodegradable materials offer especial capabilities to be used as bio-absorbable implants.However,their poor corrosion and fatigue properties in the physiological environment can restrict their applications.In this study,corrosion-fatigue tests have been performed on the extruded magnesium and magnesium/hydroxyapatite (Mg/HA) composites in a high cycle regime.To produce the composites,pure magnesium was reinforced by 2.5 wt.%and 5 wt.%of hydroxyapatite submicron particles using an electromagneticmechanical stirring method and hot extrusion process.The experimental density measurement exhibits that the porosity increases in the extruded samples with more hydroxyapatite particles.To investigate the corrosion and corrosion-fatigue behavior of the specimens,simulated body fluid (SBF) was used during in vitro tests.The results of the potentiodynamic polarization corrosion test show that the composite with 2.5 wt.%of hydroxyapatite (Mg/2.5 wt.%HA) and the pure magnesium specimen exhibit the highest and the lowest corrosion resistance,respectively.Regarding the elemental mapping analysis of the corroded samples,this behavior could be due to the formation of strong phosphorus-calcium based layers on the composite surface.The results obtained from the mechanical tests indicate that Mg/5 wt.%HA offered the highest tensile and compressive yield strengths,as well as the most promising high cycle fatigue behavior.During the corrosionfatigue test,the simultaneous effects of fatigue and corrosion damages led to a similar corrosion-fatigue behavior in both composites.The fracture surfaces of the corrosion-fatigue samples suggest that the cracks are initiated in the corroded regions of the samples surface,which reduces the crack initiation step and subsequently decreases the fatigue life.In comparison with the pure magnesium,both composites exhibit more promising corrosion and corrosion-fatigue behaviors with a significant fatigue life improvement in the physiological environment.
引用
收藏
页码:2169 / 2184
页数:16
相关论文
共 50 条
  • [1] In vitro corrosion-fatigue behavior of biodegradable Mg/HA composite in simulated body fluid
    Ghazizadeh, E.
    Jabbari, A. H.
    Sedighi, M.
    JOURNAL OF MAGNESIUM AND ALLOYS, 2021, 9 (06) : 2169 - 2184
  • [2] In vitro corrosion-fatigue behavior of biodegradable Mg/HA composite in simulated body fluid
    E.Ghazizadeh
    A.H.Jabbari
    M.Sedighi
    Journal of Magnesium and Alloys, 2021, 9 (06) : 2169 - 2184
  • [3] In Vitro Corrosion Behavior of Zn3Mg0.7Y Biodegradable Alloy in Simulated Body Fluid (SBF)
    Panaghie, Catalin
    Cimpoesu, Ramona
    Zegan, Georgeta
    Roman, Ana-Maria
    Ivanescu, Mircea Catalin
    Aelenei, Andra Adorata
    Benchea, Marcelin
    Cimpoesu, Nicanor
    Ioanid, Nicoleta
    APPLIED SCIENCES-BASEL, 2022, 12 (05):
  • [4] Crevice corrosion behavior of a biodegradable Zn-Mn-Mg alloy in simulated body fluid
    Wang, Ting
    Zhao, An-Qi
    Yan, Yu
    Wang, Lu-Ning
    BIOMATERIALS SCIENCE, 2024, 12 (19) : 4957 - 4966
  • [5] A numerical corrosion-fatigue model for biodegradable Mg alloy stents
    Shen, Zhenquan
    Zhao, Ming
    Zhou, Xiaochen
    Yang, Hongtao
    Liu, Jianing
    Guo, Hui
    Zheng, Yufeng
    Yang, Jian-An
    ACTA BIOMATERIALIA, 2019, 97 : 671 - 680
  • [6] In- vitro corrosion behavior of the cast and extruded biodegradable Mg-Zn-Cu alloys in simulated body fluid (SBF)
    Lotfpour, Mehrab
    Dehghanian, Changiz
    Emamy, Massoud
    Bahmani, Ahmad
    Malekan, Mehdi
    Saadati, Ahmad
    Taghizadeh, Milad
    Shokouhimehr, Mohammadreza
    JOURNAL OF MAGNESIUM AND ALLOYS, 2021, 9 (06) : 2078 - 2096
  • [7] In-vitro corrosion behavior of the cast and extruded biodegradable Mg-Zn-Cu alloys in simulated body fluid(SBF)
    Mehrab Lotfpour
    Changiz Dehghanian
    Massoud Emamy
    Ahmad Bahmani
    Mehdi Malekan
    Ahmad Saadati
    Milad Taghizadeh
    Mohammadreza Shokouhimehr
    Journal of Magnesium and Alloys, 2021, 9 (06) : 2078 - 2096
  • [8] Corrosion-fatigue resistance of ultrafine grain commercially pure titanium in simulated body fluid
    Naseri, Reza
    Hiradfar, Hamed
    Shariati, Mahmoud
    Kadkhodayan, Mehran
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2023, 237 (06) : 2181 - 2191
  • [9] Corrosion behavior of Mg and Mg-Zn alloys in simulated body fluid
    Gao Jia-cheng
    Wu Sha
    Qiao Li-ying
    Wang Yong
    TRANSACTIONS OF NONFERROUS METALS SOCIETY OF CHINA, 2008, 18 (03) : 588 - 592
  • [10] Corrosion behavior of Mg and Mg-Zn alloys in simulated body fluid
    高家诚
    伍沙
    乔丽英
    王勇
    TransactionsofNonferrousMetalsSocietyofChina, 2008, (03) : 588 - 592