Removal of Endotoxin from Human Serum Albumin Solutions by Hydrophobic and Cationic Charged Membrane

被引:0
|
作者
Gui Lin WEI~1
Zhen Hua SHAN~1
Ming Chen PAN~2
Zhi Hong GAO~2 (1Dalian Institute of Chemical Physics. Chinese Academy of Sciences. Dalian 1 16012 2 Dalian Medical University 1st Teaching Hospital)
机构
基金
中国国家自然科学基金;
关键词
Hydrophobic and cationic charged membrane. endotoxin removal;
D O I
暂无
中图分类号
Q936 [微生物生物化学];
学科分类号
071010 ;
摘要
A novel matrix of macropore cellulose membrane was prepared by chemical graft, and immobilized the cationic charged groups as affinity ligands. The prepared membrane can be used for the removal of endotoxin from. human serum albumin (HSA) solutions. With a cartridge of 20 sheets affinity membrane of 47 mm diameter, the endotoxin level in HSA solution can be reduced to 0.027 eu/mL. Recovery of HSA was over 95%.
引用
收藏
页码:357 / 360
页数:4
相关论文
共 50 条
  • [1] Removal of endotoxin from human serum albumin solutions by hydrophobic and cationic charged membrane
    Wei, GL
    Shang, ZH
    Pan, MC
    Gao, ZH
    CHINESE CHEMICAL LETTERS, 2000, 11 (04) : 357 - 360
  • [2] Endotoxin removal from albumin and saline solutions
    Bell, C.-M.
    Guo, K.
    Wendel, H. P.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2007, 30 (07): : 589 - 593
  • [3] Evaluation of a chitosan membrane for removal of endotoxin from human IgG solutions
    Machado, Romi Lamb
    de Arruda, Eduardo Jose
    Santana, Cesar Costapinto
    Bueno, Sonia Maria Alves
    PROCESS BIOCHEMISTRY, 2006, 41 (11) : 2252 - 2257
  • [4] Removal of endotoxin from aqueous solutions by affinity membrane
    Guo, W
    Shang, ZH
    Yu, YN
    Zhou, LM
    BIOMEDICAL CHROMATOGRAPHY, 1997, 11 (03) : 164 - 166
  • [6] Effect of cationic polymer adsorbent pKa on the selective removal of endotoxin from an albumin solution
    Sakata, M
    Todokoro, M
    Kai, T
    Kunitake, M
    Hirayama, C
    CHROMATOGRAPHIA, 2001, 53 (11-12) : 619 - 623
  • [7] Effect of cationic polymer adsorbent pKa on the selective removal of endotoxin from an albumin solution
    M. Sakata
    M. Todokoro
    T. Kai
    M. Kunitake
    C. Hirayama
    Chromatographia, 2001, 53 : 619 - 623
  • [8] Membrane adsorbers for selective endotoxin removal from protein solutions
    Anspach, FB
    Petsch, D
    PROCESS BIOCHEMISTRY, 2000, 35 (09) : 1005 - 1012
  • [9] Removal of albumin from multiple human serum samples
    Rengarajan, K
    deSmet, MD
    Wiggert, BB
    BIOTECHNIQUES, 1996, 20 (01) : 30 - &
  • [10] REMOVAL OF ETHANOL FROM ALBUMIN BY GEL-FILTRATION IN MANUFACTURING OF HUMAN SERUM-ALBUMIN SOLUTIONS FOR CLINICAL USE
    FRIEDLI, H
    KISTLER, P
    CHIMIA, 1972, 26 (01) : 25 - &