Numerical analysis of ultimate strength of concrete filled steel tubular arch bridges

被引:0
|
作者
谢旭
陈衡治
李辉
宋世锐
机构
[1] Ningbo 315211
[2] University of Manchester
[3] Manchester Hangzhou 310027
[4] Centre for Civil & Construction Engineering
[5] M601QD
[6] Department of Civil Engineering
[7] United Kingdom
[8] Ningbo University
[9] China
[10] Zhejiang University
关键词
Concrete Filled Steel Tubular (CFST); Confined concrete; Stress-strain relationship; Ultimate strength;
D O I
暂无
中图分类号
TU398.9 [];
学科分类号
081304 ; 081402 ;
摘要
The calculation of ultimate bearing capacity is a significant issue in the design of Concrete Filled Steel Tubular (CFST) arch bridges. Based on the space beam theory, this paper provides a calculation method for determining the ultimate strength of CFST structures. The accuracy of this method and the applicability of the stress-strain relationships were validated by comparing different existing confined concrete uniaxial constitutive relationships and experimental results. Comparison of these results indicated that this method using the confined concrete uniaxial stress-strain relationships can be used to calculate the ultimate strength and CFST behavior with satisfactory accuracy. The calculation results are stable and seldom affected by concrete con-stitutive relationships. The method is therefore valuable in the practice of engineering design. Finally, the ultimate strength of an arch bridge with span of 330 m was investigated by the proposed method and the nonlinear behavior was discussed.
引用
收藏
页码:859 / 868