Hemodynamics in Transplant Renal Artery Stenosis and its Alteration after Stent Implantation Based on a Patient-specific Computational Fluid Dynamics Model

被引:0
|
作者
Wang Hong-Yang
Liu Long-Shan
Cao Hai-Ming
Li Jun
Deng Rong-Hai
Fu Qian
Zhang Huan-Xi
Fei Ji-Guang
Wang Chang-Xi
机构
[1] Organ Transplant Center, The First Affiliated Hospital of Sun Yat-sen University, Guangzhou, Guangdong 510080, China
[2] Guangdong Provincial Key Laboratory on Organ Donation and Transplant Immunology, Guangzhou, Guangdong 510080, China
关键词
Hemodynamics; Kidney Transplantation; Patient-specific Modeling; Renal Artery Obstruction;
D O I
暂无
中图分类号
R699.2 [肾脏手术];
学科分类号
摘要
Background: Accumulating studies on computational fluid dynamics (CFD) support the involvement of hemodynamic factors in artery stenosis. Based on a patient-specific CFD model, the present study aimed to investigate the hemodynamic characteristics of transplant renal artery stenosis (TRAS) and its alteration after stent treatment. Methods: Computed tomography angiography (CTA) data of kidney transplant recipients in a single transplant center from April 2013 to November 2014 were reviewed. The three-dimensional geometry of transplant renal artery (TRA) was reconstructed from the qualified CTA images and categorized into three groups: the normal, stenotic, and stented groups. Hemodynamic parameters including pressure distribution, velocity, wall shear stress (WSS), and mass flow rate (MFR) were extracted. The data of hemodynamic parameters were expressed as median (interquartile range), and Mann–WhitneyU-test was used for analysis.Results: Totally, 6 normal, 12 stenotic, and 6 stented TRAs were included in the analysis. TRAS presented nonuniform pressure distribution, adverse pressure gradient across stenosis throat, flow vortex, and a separation zone at downstream stenosis. Stenotic arteries had higher maximal velocity and maximal WSS (2.94 [2.14, 3.30] vs. 1.06 [0.89, 1.15] m/s, 256.5 [149.8, 349.4] vs. 41.7 [37.8, 45.3] Pa at end diastole,P= 0.001; 3.25 [2.67, 3.56] vs. 1.65 [1.18, 1.72] m/s, 281.3 [184.3, 364.7] vs. 65.8 [61.2, 71.9] Pa at peak systole,P= 0.001) and lower minimal WSS and MFRs (0.07 [0.03, 0.13] vs. 0.52 [0.45, 0.67] Pa, 1.5 [1.0, 3.0] vs. 11.0 [8.0, 11.3] g/s at end diastole,P = 0.001; 0.08 [0.03, 0.19] vs. 0.70 [0.60, 0.81] Pa, 2.0 [1.3, 3.3] vs. 16.5 [13.0, 20.3] g/s at peak systole,P = 0.001) as compared to normal arteries. Stent implantation ameliorated all the alterations of the above hemodynamic factors except low WSS.Conclusions: Hemodynamic factors were significantly changed in severe TRAS. Stent implantation can restore or ameliorate deleterious change of hemodynamic factors except low WSS at stent regions.
引用
收藏
页码:23 / 31
页数:9
相关论文
共 50 条
  • [1] Hemodynamics in Transplant Renal Artery Stenosis and its Alteration after Stent Implantation Based on a Patient-specific Computational Fluid Dynamics Model
    Wang, Hong-Yang
    Liu, Long-Shan
    Cao, Hai-Ming
    Li, Jun
    Deng, Rong-Hai
    Fu, Qian
    Zhang, Huan-Xi
    Fei, Ji-Guang
    Wang, Chang-Xi
    CHINESE MEDICAL JOURNAL, 2017, 130 (01) : 23 - 31
  • [2] Hemodynamics in transplant renal artery investigated by computational fluid dynamics
    Wang, Hongyang
    Cao, Haiming
    Li, Jun
    Liu, Longshan
    Fu, Qian
    Fei, Jiguang
    Wang, Changxi
    TRANSPLANTATION, 2016, 100 (07) : S643 - S643
  • [3] Patient-specific assessment of hemodynamics by computational fluid dynamics in patients with bicuspid aortopathy
    Kimura, Naoyuki
    Nakamura, Masanori
    Komiya, Kenji
    Nishi, Satoshi
    Yamaguchi, Atsushi
    Tanaka, Osamu
    Misawa, Yoshio
    Adachi, Hideo
    Kawahito, Koji
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2017, 153 (04): : S52 - +
  • [4] Haemodynamic impact of stent implantation for lateral tunnel Fontan stenosis: a patient-specific computational assessment
    Tang, Elaine
    McElhinney, Doff B.
    Restrepo, Maria
    Valente, Anne M.
    Yoganathan, Ajit P.
    CARDIOLOGY IN THE YOUNG, 2016, 26 (01) : 116 - 126
  • [5] A Workflow for the Numerical Evaluation of Hemodynamics in a Patient-Specific AAA After Stent-Graft Implantation
    Bertolini, Michele
    Rossoni, Marco
    Colombo, Giorgio
    DESIGN TOOLS AND METHODS IN INDUSTRIAL ENGINEERING II, ADM 2021, 2022, : 827 - 835
  • [6] MANUFACTURING AND COMPUTATIONAL FLUID DYNAMICS MODELING OF A PATIENT-SPECIFIC FISTULA MODEL
    Liu, Yang
    Zheng, Yihao
    Pitre, John
    Weitzel, William
    Bull, Joseph
    Shih, Albert
    PROCEEDINGS OF THE ASME 12TH INTERNATIONAL MANUFACTURING SCIENCE AND ENGINEERING CONFERENCE - 2017, VOL 4, 2017,
  • [7] Effect of stenosis on hemodynamics in left coronary artery based on patient-specific CT scan
    Kamangar, Sarfaraz
    Ahmed, N. J. Salman
    Badruddin, Irfan Anjum
    Al-Rawahi, Nabeel
    Husain, Afzal
    Govindaraju, Kalimuthu
    Khan, T. M. Yunus
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2019, 30 (04) : 463 - 473
  • [8] Hemodynamics in stented vertebral artery ostial stenosis based on computational fluid dynamics simulations
    Qiao, Aike
    Dai, Xuan
    Niu, Jing
    Jiao, Liqun
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2016, 19 (11) : 1190 - 1200
  • [9] Optimizing distal and proximal splenic artery embolization with patient-specific computational fluid dynamics
    Tatari, Younes
    Smith, Tyler Andrew
    Hu, Jingjie
    Arzani, Amirhossein
    JOURNAL OF BIOMECHANICS, 2024, 176
  • [10] Patient-specific computational fluid dynamics of femoro-popliteal stent-graft thrombosis
    Conti, Michele
    Ferrarini, Anna
    Finotello, Alice
    Salsano, Giancarlo
    Auricchio, Ferdinando
    Palombo, Domenico
    Spinella, Giovanni
    Pane, Bianca
    MEDICAL ENGINEERING & PHYSICS, 2020, 86 : 57 - 64