Comparison of retinal nerve fiber layer and macular thickness measurements with Stratus OCT and OPKO/OTI OCT devices in healthy subjects

被引:0
|
作者
Ahmet Ozkok [1 ]
Julide Canan Umurhan Akkan [2 ]
Nevbahar Tamcelik [1 ]
Mehmet Erdogan [1 ]
Didar Ucar Comlekoglu [1 ]
Rengin Yildirim [1 ]
机构
[1] Department of Ophthalmology,Cerrahpasa School of Medicine,Istanbul University
[2] Department of Ophthalmology,School of Medicine,Bezmialem Vakif University
关键词
optical coherence tomography; Stratus optical coherence tomography; OPKO/OTI OCT; retinal nerve fiber layer; macular thickness;
D O I
暂无
中图分类号
R770.4 [眼科诊断学];
学科分类号
100212 ;
摘要
AIM: To compare retinal nerve fiber layer(RNFL) and macular thickness measurements obtained with the Stratus optical coherence tomography(OCT) and OPKO/OTI OCT devices.METHODS: Included in the study were 59 eyes of 30 participants. All measurements for each eye were done on the same day with both devices. Student’s paired t-tests were used to compare the central macular thickness and RNFL measurements of the Stratus OCT and OPKO/OTI OCT. Pearson correlation was used to assess the relationship between the devices. Coefficient of variation(COV) was calculated to assess intersession repeatability.RESULTS: Using both the Stratus OCT and OPKO/OTI OCT, respectively, the measured mean average RNFL thicknesses were 98.9±11.1 μm and 115.1±9.6 μm(P =0.001),and the measured mean central retinal thicknesses(CRT)were 196.2 ±18.8 μm and 204.5 ±21.1 μm(P <0.001).Measured by the two devices, the RNFL thickness values were correlated in all quadrants, as were the retinal thickness values except the inferior outer sector. COV for average RNFL and CRT thickness were 2.9% and 4.6%for Stratus OCT, and 2.1% and 4.2% for OPKO/OTI OCT,respectively.CONCLUSION: We found good reproducibility of RNFL and retina thickness measurements for both Stratus OCT and OPKO/OTI OCT devices. However, even though the two OCT systems provided statistically correlated results,the values for both RNFL and macular thickness were statistically different. RNFL and macular thickness measurements with the OPKO/OTI OCT were higher than that of the Stratus OCT; therefore, the two OCT systems cannot be used interchangeably for the measurements of RNFL and macular thickness.
引用
收藏
页码:98 / 103
页数:6
相关论文
共 50 条
  • [1] Comparison of retinal nerve fiber layer and macular thickness measurements with Stratus OCT and OPKO/OTI OCT devices in healthy subjects
    Ozkok, Ahmet
    Akkan, Julide Canan Umurhan
    Tamcelik, Nevbahar
    Erdogan, Mehmet
    Comlekoglu, Didar Ucar
    Yildirim, Rengin
    [J]. INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2015, 8 (01) : 98 - 103
  • [2] Detection of Glaucoma Progression with Stratus OCT Retinal Nerve Fiber Layer, Optic Nerve Head, and Macular Thickness Measurements
    Medeiros, Felipe A.
    Zangwill, Linda M.
    Alencar, Luciana M.
    Bowd, Christopher
    Sample, Pamela A.
    Susanna, Remo, Jr.
    Weinreb, Robert N.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (12) : 5741 - 5748
  • [3] Analysis of retinal nerve fiber layer and macular thickness measurements in healthy Taiwanese individuals using optical coherence tomography (Stratus OCT)
    Hsu, Sheng-Yao
    Tsai, Rong-Kung
    [J]. JOURNAL OF GLAUCOMA, 2008, 17 (01) : 30 - 35
  • [4] Influence of pupil size and cataract on retinal nerve fiber layer thickness measurements by stratus OCT
    Savini, Giacomo
    Zanini, Maurizio
    Barboni, Piero
    [J]. JOURNAL OF GLAUCOMA, 2006, 15 (04) : 336 - 340
  • [5] Determinants of normal retinal nerve fiber layer thickness measured by stratus OCT
    Budenz, Donald L.
    Anderson, Douglas R.
    Varma, Rohit
    Schuman, Joel
    Cantor, Louis
    Savell, Jonathan
    Greenfeld, David S.
    Patella, Vincent Michael
    Quigley, Harry A.
    Tielsch, James
    [J]. OPHTHALMOLOGY, 2007, 114 (06) : 1046 - 1052
  • [6] Macular and Retinal Nerve Fiber Layer Thickness Measurements in Normal Eyes With the Stratus OCT, the Cirrus HD-OCT, and the Topcon 3D OCT-1000
    Huang, Jingjing
    Liu, Xing
    Wu, Ziqiang
    Guo, Xinxing
    Xu, Hongzhi
    Dustin, Laurie
    Sadda, Srinivas
    [J]. JOURNAL OF GLAUCOMA, 2011, 20 (02) : 118 - 125
  • [7] Stratus OCT Signal Strength and Reliability of Retinal Nerve Fiber Layer Measurements
    Liu, Ying
    Samarawickrama, Chameen
    Pai, Amy
    Tariq, Yasser
    Mitchell, Paul
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2010, 149 (03) : 528 - 529
  • [8] Transitioning from stratus OCT to cirrus OCT: a comparison and a proposed equation to convert central subfield macular thickness measurements in healthy subjects
    Abedi, Gelareh
    Patal, Payal
    Doros, Gheorghe
    Subramanian, Manju L.
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 249 (09) : 1353 - 1357
  • [9] Transitioning from stratus OCT to cirrus OCT: a comparison and a proposed equation to convert central subfield macular thickness measurements in healthy subjects
    Gelareh Abedi
    Payal Patal
    Gheorghe Doros
    Manju L. Subramanian
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2011, 249
  • [10] Reproducibility of peripapillary retinal nerve fiber thickness measurements with stratus OCT in glaucomatous eyes
    Budenz, Donald L.
    Fredette, Marie-Josee
    Feuer, William J.
    Anderson, Douglas R.
    [J]. OPHTHALMOLOGY, 2008, 115 (04) : 661 - 666