Effect of high-frequency loading and parathyroid hormone administration on peri-implant bone healing and osseointegration

被引:0
|
作者
Aya Shibamoto [1 ]
Toru Ogawa [1 ]
Joke Duyck [2 ]
Katleen Vandamme [2 ]
Ignace Naert [2 ]
Keiichi Sasaki [1 ]
机构
[1] Division of Advanced Prosthetic Dentistry,Tohoku University Graduate School of Dentistry
[2] Department of Oral Health Sciences,Prosthetic Dentistry,BIOMAT—Biomaterials,Katholieke Universiteit Leuven
关键词
D O I
暂无
中图分类号
R580 [];
学科分类号
1002 ; 100201 ;
摘要
The objective of this study is to examine the effect of low-magnitude, high-frequency(LMHF) loading, and anti-osteoporosis medications such as parathyroid hormone(PTH) and bisphosphonates on peri-implant bone healing in an osteoporosis model, and to assess their combined effects on these processes. Thirteen-week-old ovariectomized rats(n = 44) were divided into three groups:PTH, alendronate, and saline. After 3 weeks of drug administration, titanium implants were inserted into the tibiae. Each group was subdivided into two groups: with or without LMHF loading via whole-body vibration(50 Hz at 0.5 g, 15 min per day, 5 days per week). Rats were killed 4 weeks following implantation. Removal torque test, micro-CT analyses(relative gray(RG) value, water = 0,and implant = 100), and histomorphometric analyses(bone-to-implant contact(BIC) and peri-implant bone formation(bone volume/tissue volume(BV/TV))) were performed. Removal torque values and BIC were significantly differed by loading and drug administration(ANOVA). Post hoc analysis showed that PTH-treated groups were significantly higher than the other drug-treated groups. BV/TV was significantly enhanced by PTH administration. In cortical bone, RG values were significantly increased by loading.In trabecular bone, however, RG values were significantly increased by PTH administration. These findings suggest that LMHF loading and PTH can act locally and additively on the bone healing process, improving the condition of implant osseointegration.
引用
收藏
页码:50 / 56
页数:7
相关论文
共 50 条
  • [1] Effect of high-frequency loading and parathyroid hormone administration on peri-implant bone healing and osseointegration
    Aya Shibamoto
    Toru Ogawa
    Joke Duyck
    Katleen Vandamme
    Ignace Naert
    Keiichi Sasaki
    [J]. International Journal of Oral Science, 10
  • [2] Effect of high-frequency loading and parathyroid hormone administration on peri-implant bone healing and osseointegration
    Shibamoto, Aya
    Ogawa, Toru
    Duyck, Joke
    Vandamme, Katleen
    Naert, Ignace
    Sasaki, Keiichi
    [J]. INTERNATIONAL JOURNAL OF ORAL SCIENCE, 2018, 10
  • [3] Effect of high-frequency loading and parathyroid hormone administration on peri-implant bone healing and osseointegration
    Aya Shibamoto
    Toru Ogawa
    Joke Duyck
    Katleen Vandamme
    Ignace Naert
    Keiichi Sasaki
    [J]. International Journal of Oral Science, 2018, (01) - 56
  • [4] The effect of low-magnitude high-frequency loading on peri-implant bone healing and implant osseointegration in Beagle dogs
    Wang, Shuhua
    Ogawa, Toru
    Zheng, Sheng
    Miyashita, Makiko
    Tenkumo, Taichi
    Gu, Zhiyuan
    Lian, Wenhai
    Sasaki, Keiichi
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2018, 62 (04) : 497 - 502
  • [5] High-Frequency Ultrasound for Assessment of Peri-Implant Bone Thickness
    Marotti, Juliana
    Neuhaus, Sarah
    Habor, Daniel
    Bohner, Lauren
    Heger, Stefan
    Radermacher, Klaus
    Wolfart, Stefan
    [J]. JOURNAL OF CLINICAL MEDICINE, 2019, 8 (10)
  • [6] In vivo assessment of the effect of controlled high- and low-frequency mechanical loading on peri-implant bone healing
    Zhang, Xiaolei
    Vandamme, Katleen
    Torcasio, Antonia
    Ogawa, Toru
    van Lenthe, G. Harry
    Naert, Ignace
    Duyck, Joke
    [J]. JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2012, 9 (72) : 1697 - 1704
  • [7] High-frequency loading positively impacts titanium implant osseointegration in impaired bone
    Chatterjee, M.
    Hatori, K.
    Duyck, J.
    Sasaki, K.
    Naert, I.
    Vandamme, K.
    [J]. OSTEOPOROSIS INTERNATIONAL, 2015, 26 (01) : 281 - 290
  • [8] High-frequency loading positively impacts titanium implant osseointegration in impaired bone
    M. Chatterjee
    K. Hatori
    J. Duyck
    K. Sasaki
    I. Naert
    K. Vandamme
    [J]. Osteoporosis International, 2015, 26 : 281 - 290
  • [9] ACCURACY OF HIGH-FREQUENCY ULTRASOUND SCANNER IN DETECTING PERI-IMPLANT BONE DEFECTS
    Bohner, Lauren
    Habor, Daniel
    Gremse, Felix
    Tortamano, Pedro
    Wolfart, Stefan
    Marotti, Juliana
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (03): : 650 - 659
  • [10] Direct High-Frequency Stimulation of Peri-Implant Rabbit Bone: A Pilot Study
    Zhang, Xiaolei
    Naert, Ignace
    Van Schoonhoven, Dorien
    Duyck, Joke
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 (04) : 558 - 564