Simple and cost-effective determination of ciprofloxacin hydrochloride by electrical micro-titration

被引:0
|
作者
Xu-Zhi Zhang [1 ]
Meng-Shi Huang [1 ,2 ]
Qian-Qian Yang [1 ,2 ]
Dong-Sheng Ding [1 ]
Jun Zhao [1 ]
Wen-Rong Yang [3 ]
Ke-Ming Qu [1 ]
机构
[1] Yellow Sea Fisheries Research Institute, Chinese Academy of Fishery Sciences, Qingdao National Laboratory for Marine Science and Technology
[2] College of Marine Sciences, Shanghai Ocean University
[3] School of Life and Environmental Sciences, Deakin University
关键词
Ciprofloxacin hydrochloride; Determination; Micro-titration; Capacitively coupled contactless; conductivity detector; Pharmaceutical analysis;
D O I
暂无
中图分类号
O657.1 [电化学分析法]; TQ465 [抗菌素制造];
学科分类号
070302 ; 081704 ; 100705 ;
摘要
By employing an electrical micro-titration system, in which a capacitively coupled contactless conductivity detector(C4D) was used to monitor the reaction process in real time, herein a novel method for determining ciprofloxacin hydrochloride(CIPHCl) was developed for the first time. Mode 1: Standard CIPHCl solutions at different concentrations were loaded into reaction cells, respectively, and were titrated with standard Ag+. Upon the titration, the formation of a precipitate alters the number of ions in the solution, raising the change of conductivity, which was monitored by a special C4D to construct a titration curve. The endpoint of the titration was located from the peak of the curve. Between the elapsed time and the initial concentration of titrand, a linear relationship was established over the range of2.0–8.0 mmol/L. Mode 2: Standard Fe3+took the place of Ag+, and was used as titrant to recognize ciprofloxacin contributed to the formation of complexation, which also resulting a change of solution conductivity. Under optimized conditions, a working range of 1.0–5.0 mmol/L CIPHCl was found. Because the reaction solutions were isolated from the working electrodes, this pioneer work shows significant simplicity and cost-effectiveness, by eliminating the requirements for detector exchange/renewal between different measurements, and by involving no auxiliary chemicals. Both of the two approaches were applied successfully to determine CIPHCl in tablet samples. And the results were in good agreement with those obtained by reference method.
引用
收藏
页码:1406 / 1412
页数:7
相关论文
共 50 条
  • [1] Simple and cost-effective determination of ciprofloxacin hydrochloride by electrical micro-titration
    Zhang, Xu-Zhi
    Huang, Meng-Shi
    Yang, Qian-Qian
    Ding, Dong-Sheng
    Zhao, Jun
    Yang, Wen-Rong
    Qu, Ke-Ming
    CHINESE CHEMICAL LETTERS, 2017, 28 (07) : 1406 - 1412
  • [2] A simple, ultrasensitive and cost-effective electrochemical sensor for the determination of ciprofloxacin in various types of samples
    Adane, Wondimeneh Dubale
    Chandravanshi, Bhagwan Singh
    Tessema, Merid
    SENSING AND BIO-SENSING RESEARCH, 2023, 39
  • [3] DESCRIPTION AND ANALYSIS OF A SIMPLE MICRO-TITRATION IMMUNE CYTOLYTIC TEST
    SPOONER, RL
    BOWDEN, FW
    CARPENTER, RG
    JOURNAL OF HYGIENE-CAMBRIDGE, 1965, 63 (03): : 369 - +
  • [4] A SIMPLE AND COST-EFFECTIVE PULSE RECORDER FOR THE BBC MICRO
    CHANDLER, PR
    JOURNAL OF BIOLOGICAL EDUCATION, 1989, 23 (01) : 6 - 7
  • [5] A simple and cost-effective strategy for electrochemiluminescence spectral determination
    Zhang, Yifei
    Gao, Dexin
    Yang, Hongye
    Gao, Wenyue
    Wu, Chi
    ANALYTICA CHIMICA ACTA, 2024, 1324
  • [6] A Simple, Cost-effective, and Environmentally Friendly Method for Determination of Ciprofloxacin in Drugs and Urine Samples Based on Electrogenerated Chemiluminescence
    Pavao, Daniele
    Nascimento Botelho, Chirlene
    Nunes Fernandes, Ridvan
    Costa dos Santos, Clenilton
    Santos Damos, Flavio
    de Cassia Silva Luz, Rita
    ELECTROANALYSIS, 2020, 32 (07) : 1498 - 1506
  • [7] Simultaneous and automatic determination of hydroxide and carbonate in aluminate solutions by a micro-titration method
    Tan, AM
    Zhang, L
    Xiao, CL
    ANALYTICA CHIMICA ACTA, 1999, 388 (1-2) : 219 - 223
  • [8] Simple and Cost-effective “Turn-on” Fluorescence Sensor for the Determination of Xanthine
    Manna Rachel Mathew
    Sanu K. Anand
    Jerzy Radecki
    Hanna Radecka
    K. Girish Kumar
    Journal of Fluorescence, 2020, 30 : 695 - 702
  • [9] Simple, rapid and cost-effective method for the determination of zirconium in different samples
    Hamed, Mostafa M.
    Aglan, Refaat F.
    MICROCHEMICAL JOURNAL, 2019, 149
  • [10] Simple and Cost-Effective Method for Reliable Indirect Determination of Field Capacity
    Almaz, Cansu
    Mihalikova, Marketa
    Batkova, Kamila
    Vopravil, Jan
    Matula, Svatopluk
    Khel, Tomas
    Kara, Recep Serdar
    HYDROLOGY, 2023, 10 (10)