Experimental Study on Triggering Characteristics of a Surface Flashover Triggered Vacuum Switch

被引:0
|
作者
姚学玲 [1 ]
陈景亮 [1 ]
孙伟 [2 ]
机构
[1] Electrical Engineering Institute of Xi'an Jiaotong University,State Key Laboratory of Electrical Insulation and Power Equipment
[2] Mechanical and Electrical Engineering Dept.,Xi'an University of Architecture and Technology
关键词
surface flashover; dielectric material; TVS(triggered vacuum switch); discharge delay time; delay jitter;
D O I
暂无
中图分类号
TM564.2 [负荷开关];
学科分类号
080801 ;
摘要
Triggering characteristics of triggered vacuum switch (TVS),including the dischargedelay time,delay jitter,range of operational voltage and peak of pulsed current,are investigated.Both structure and experimental circuit of TVS are presented.The results indicate that TVS,asa surface flashover triggering device with high dielectric permittivity material,is with excellenttriggering characteristics.When the hold-off voltage reaches 120 kV,the minimum operationalvoltage is 1.3 kV,and the minimum discharge delay time and jitter are 100 ns and ±10 ns,respectively.The peak current is up to 240 kA when the operational voltage reaches 100 kV.TVScan well satisfy the main demands of high voltage and current applications,and can also be usedunder a multi-crowbar circuit.
引用
收藏
页码:734 / 737
页数:4
相关论文
共 50 条
  • [1] Experimental Study on Triggering Characteristics of a Surface Flashover Triggered Vacuum Switch
    Yao Xueling
    Chen Jingliang
    Sun Wei
    PLASMA SCIENCE & TECHNOLOGY, 2010, 12 (06) : 734 - 737
  • [2] Experimental Study on Triggering Characteristics of a Surface Flashover Triggered Vacuum Switch
    姚学玲
    陈景亮
    孙伟
    Plasma Science and Technology, 2010, (06) : 734 - 737
  • [3] Improving Triggering Characteristics for a Surface-Flashover Triggered Vacuum Switch
    He, Z.
    Wang, L.
    Li, F.
    Yao, W.
    Dong, M.
    Zhao, C.
    ACTA PHYSICA POLONICA A, 2009, 115 (06) : 1019 - 1021
  • [4] An experimental study on initial plasma characteristics of surface flashover triggered vacuum switch
    Hu, S., 1600, Chinese Machine Press, 1 Nanjie Baiwanzhuang, Beijig, 100037, China (27):
  • [5] Experimental study on laser triggered surface flashover switch in vacuum
    Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing 100080, China
    不详
    Qiangjiguang Yu Lizishu, 2007, 6 (1027-1030):
  • [6] Experimental research of triggering characteristics of the surface breakdown type triggered vacuum switch
    Zhao, Chun
    Dong, Man-Ling
    Wang, Lei
    He, Jun-Jia
    Gaodianya Jishu/High Voltage Engineering, 2008, 34 (02): : 230 - 233
  • [7] Research on the Characteristics of a Triggered Vacuum Switch with a Surface Flashover Trigger Device
    Wung-Hoa Park
    Hyung Seop Kong
    Suk Ho An
    Byung-Joon Lee
    Journal of the Korean Physical Society, 2020, 77 : 919 - 923
  • [8] Research on the Operating Characteristics of Electrically Triggered Vacuum Surface Flashover Switch
    Ye, Mingtian
    Wang, Zhen
    Long, Tianjun
    Wang, Junyan
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2023, 51 (02) : 493 - 497
  • [9] Research on the Characteristics of a Triggered Vacuum Switch with a Surface Flashover Trigger Device
    Park, Wung-Hoa
    Kong, Hyung Seop
    An, Suk Ho
    Lee, Byung-Joon
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2020, 77 (10) : 919 - 923
  • [10] Research on the trigger process of surface flashover triggered vacuum switch
    Zhang, Ming
    Liao, Minfu
    Lu, Gang
    Ma, Hui
    Meng, Qingxin
    Duan, Xiongying
    Han, Xiaotao
    VACUUM, 2023, 211