At wavelength coherent scatterometry microscope using high-order harmonics for EUV mask inspection

被引:0
|
作者
Yutaka Nagata [1 ]
Tetsuo Harada [2 ]
Takeo Watanabe [2 ]
Hiroo Kinoshita [2 ]
Katsumi Midorikawa [1 ]
机构
[1] RIKEN Center for Advanced Photonics, RIKEN
[2] Center for EUV Lithography, Laboratory of Advanced Science and Technology for Industry, University of Hyogo
关键词
D O I
暂无
中图分类号
TH742 [显微镜];
学科分类号
0803 ;
摘要
In this review, we describe our research on the development of the 13.5 nm coherent microscope using high-order harmonics for the mask inspection of extreme ultraviolet(EUV) lithography.EUV lithography is a game-changing piece of technology for high-volume manufacturing of commercial semiconductors. Many top manufacturers apply EUV technology for fabricating the most critical layers of 7 nm chips. Fabrication and inspection of defect-free masks, however, still remain critical issues in EUV technology. Thus, in our pursuit for a resolution, we have developed the coherent EUV scatterometry microscope(CSM) system with a synchrotron radiation(SR) source to establish the actinic metrology, along with inspection algorithms. The intensity and phase images of patterned EUV masks were reconstructed from diffraction patterns using ptychography algorithms. To expedite the practical application of the CSM, we have also developed a standalone CSM, based on high-order harmonic generation, as an alternative to the SR-CSM. Since the application of a coherent 13.5 nm harmonic enabled the production of a high contrast diffraction pattern, diffraction patterns of sub-100 ns size defects in a 2 D periodic pattern mask could be observed. Reconstruction of intensity and phase images from diffraction patterns were also performed for a periodic line-and-space structure, an aperiodic angle edge structure, as well as a cross pattern in an EUV mask.
引用
收藏
页码:4 / 15
页数:12
相关论文
共 50 条
  • [1] At wavelength coherent scatterometry microscope using high-order harmonics for EUV mask inspection
    Nagata, Yutaka
    Harada, Tetsuo
    Watanabe, Takeo
    Kinoshita, Hiroo
    Midorikawa, Katsumi
    [J]. INTERNATIONAL JOURNAL OF EXTREME MANUFACTURING, 2019, 1 (03)
  • [2] Development of coherent EUV scatterometry microscope with high-order harmonic for EUV mask inspection
    Nagata, Yutaka
    Harada, Tetsuo
    Nakasuji, Masato
    Kinoshita, Hiroo
    Midorikawa, Katsumi
    [J]. X-RAY LASERS AND COHERENT X-RAY SOURCES: DEVELOPMENT AND APPLICATIONS X, 2013, 8849
  • [3] Development of highly spatial-coherent, 13.5-nm high-order harmonics for EUVL mask inspection using coherent EUV scatterometry microscope
    Nagata, Yutaka
    Harada, Tetsuo
    Nakasuji, Masato
    Kinoshita, Hiroo
    Midorikawa, Katsumi
    [J]. 2012 IEEE PHOTONICS CONFERENCE (IPC), 2012, : 935 - +
  • [4] The Coherent EUV Scatterometry Microscope for Actinic Mask Inspection and Metrology
    Harada, Tetsuo
    Nakasuji, Masato
    Kimura, Teruhiko
    Nagata, Yutaka
    Watanabe, Takeo
    Kinoshita, Hiroo
    [J]. PHOTOMASK AND NEXT-GENERATION LITHOGRAPHY MASK TECHNOLOGY XVIII, 2011, 8081
  • [5] EUV mask observations using a coherent EUV scatterometry microscope with a high-harmonic-generation source
    Fujino, Takahiro
    Tanaka, Yusuke
    Harada, Tetsuo
    Nagata, Yutaka
    Watanabe, Takeo
    Kinoshita, Hiroo
    [J]. PHOTOMASK JAPAN 2015: PHOTOMASK AND NEXT-GENERATION LITHOGRAPHY MASK TECHNOLOGY XXII, 2015, 9658
  • [6] Observation of EUVL mask using coherent EUV scatterometry microscope with high-harmonic-generation EUV source
    Mamezaki, Daiki
    Harada, Tetsuo
    Nagata, Yutaka
    Watanabe, Takeo
    [J]. PHOTOMASK JAPAN 2017: XXIV SYMPOSIUM ON PHOTOMASK AND NEXT-GENERATION LITHOGRAPHY MASK TECHNOLOGY, 2017, 10454
  • [7] Development of Actual EUV Mask Observation Method for Micro Coherent EUV Scatterometry Microscope
    Harada, T.
    Hashimoto, H.
    Watanabe, T.
    [J]. PHOTOMASK TECHNOLOGY 2016, 2016, 9985
  • [8] Development of Coherent Extreme-Ultraviolet Scatterometry Microscope with High-Order Harmonic Generation Source for Extreme-Ultraviolet Mask Inspection and Metrology
    Nakasuji, Masato
    Tokimasa, Akifumi
    Harada, Tetsuo
    Nagata, Yutaka
    Watanabe, Takeo
    Midorikawa, Katsumi
    Kinoshita, Hiroo
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS, 2012, 51 (06)
  • [9] Pattern inspection of EUV mask using a EUV microscope
    Watanabe, T
    Haga, T
    Shoki, T
    Hamamoto, K
    Takada, S
    Kazui, N
    Kakunai, S
    Tsubakino, H
    Kinoshita, H
    [J]. PHOTOMASK AND NEXT-GENERATION LITHOGRAPHY MASK TECHNOLOGY X, 2003, 5130 : 1005 - 1013
  • [10] Development of a Coherent EUV Scatterometry Microscope
    Kinoshita, Hiroo
    Harada, Tetsuo
    Nagata, Yutaka
    Watanabe, Takeo
    Midorikawa, Katsumi
    [J]. 2013 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2013,