Polydimethylsiloxane Microchip Capillary Electrophoresis for Determination of Cholesterol
被引:0
|
作者:
论文数: 引用数:
h-index:
机构:
Nipapan Ruecha
[1
]
Weena Siangproh
论文数: 0引用数: 0
h-index: 0
机构:
Department of Chemistry,Faculty of Science,Srinakharinwirot University,Sukhumvit 23,Wattana,Bangkok 10110,ThailandPetrochemistry and Polymer Science,Faculty of Science,Chulalongkorn University,Patumwan,Bangkok 10330,Thailand
Weena Siangproh
[2
]
Orawon Chailapakul
论文数: 0引用数: 0
h-index: 0
机构:
Dapartment of Chemistry,Faculty of Science and Center of Innovative Nanotechnology,Chulalongkorn University,ThailandPetrochemistry and Polymer Science,Faculty of Science,Chulalongkorn University,Patumwan,Bangkok 10330,Thailand
Orawon Chailapakul
[3
]
机构:
[1] Petrochemistry and Polymer Science,Faculty of Science,Chulalongkorn University,Patumwan,Bangkok 10330,Thailand
[2] Department of Chemistry,Faculty of Science,Srinakharinwirot University,Sukhumvit 23,Wattana,Bangkok 10110,Thailand
[3] Dapartment of Chemistry,Faculty of Science and Center of Innovative Nanotechnology,Chulalongkorn University,Thailand
Microchip capillary electrophoresis(MCE) has significant impact on diagnostic testing.One of the most importance in clinical analysis test is the determination of cholesterol level in blood,because its increase is associated with coronary heart disease which is a major cause of death world over.Poly-dimethylsiloxane(PDMS) was material used to make a MCE for determination of cholesterol.Hydrogen peroxide was generated from the oxidation of cholesterol with cholesterol oxidase(ChOx) and was detected electrochemically at a downstream gold(Au) wire electrode by amperometry.Various parameters,such as the detection potential,concentration of running buffer,pH of running buffer,separation voltage,injection time,and concentration of ChOx,were studied.The migration time of cholesterol is less than 100 s and the calibration curve is linear from 50 mg·dL-1 to 250 mg·dL-1 with the coefficient of determination(R2) of 0.9955.Therefore,this proposed assay is very rapid and sensitive for the detection of cholesterol.
机构:
Chinese Acad Sci, Inst Elect, State Key Lab Transducer Technol, Beijing 100080, Peoples R ChinaChinese Acad Sci, Inst Elect, State Key Lab Transducer Technol, Beijing 100080, Peoples R China
Wang, M
Cui, DF
论文数: 0引用数: 0
h-index: 0
机构:
Chinese Acad Sci, Inst Elect, State Key Lab Transducer Technol, Beijing 100080, Peoples R ChinaChinese Acad Sci, Inst Elect, State Key Lab Transducer Technol, Beijing 100080, Peoples R China
Cui, DF
Wang, L
论文数: 0引用数: 0
h-index: 0
机构:
Chinese Acad Sci, Inst Elect, State Key Lab Transducer Technol, Beijing 100080, Peoples R ChinaChinese Acad Sci, Inst Elect, State Key Lab Transducer Technol, Beijing 100080, Peoples R China
Wang, L
Chen, XA
论文数: 0引用数: 0
h-index: 0
机构:
Chinese Acad Sci, Inst Elect, State Key Lab Transducer Technol, Beijing 100080, Peoples R ChinaChinese Acad Sci, Inst Elect, State Key Lab Transducer Technol, Beijing 100080, Peoples R China
Chen, XA
Teng, F
论文数: 0引用数: 0
h-index: 0
机构:
Chinese Acad Sci, Inst Elect, State Key Lab Transducer Technol, Beijing 100080, Peoples R ChinaChinese Acad Sci, Inst Elect, State Key Lab Transducer Technol, Beijing 100080, Peoples R China
Teng, F
INTERNATIONAL CONFERENCE ON SENSOR TECHNOLOGY (ISTC 2001), PROCEEDINGS,
2001,
4414
: 38
-
39