Assessment of left ventricular ejection fraction: comparison of two dimensional echocardiography, cardiac magnetic resonance imaging and 64-row multi-detector computed tomography

被引:0
|
作者
Chee Khoon LIEW
Rapaee ANNUAR
Tiong Kiam ONG
Sze Piaw CHIN
Tobias Seyfarth
Yean Yip FONG
Choon Kiat ANG
Houng Bang LIEW
Kui Hian SIM
机构
[1] Germany
[2] University Malaysia Sarawak
[3] Department of Cardiology Sarawak General Hospital Sarawak Malaysia
[4] Siemens Cardiac Solutions Erlangen
[5] Department of Cardiology Sarawak General Hospital Sarawak Malaysia
关键词
ejection fraction; echocardiography; magnetic resonance imaging; computed tomography;
D O I
暂无
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Objectives To compare left ventricular ejection fraction (LVEF) determined from 64-row multi-detector computed tomography (64-row MDCT) with those determined from two dimensional echocardiography (2D echo) and cardiac magnetic resonance imaging (CMR). Methods Thirty-two patients with coronary artery disease underwent trans-thoracic 2D echo, CMR and contrast-enhanced 64-row MDCT for assessment of LVEF within 48 hours of each other. 64-row MDCT LVEF was derived using the Syngo Circulation software; CMR LVEF was by Area Length Ejection Fraction (ALEF) and Simpson method and 2D echo LVEF by Simpson method. Results The LVEF was 49.13±15.91 % by 2D echo, 50.72±16.55% (ALEF method) and 47.65±16.58%(Simpson method) by CMR and 50.00±15.93% by 64-row MDCT. LVEF measurements by 64-row MDCT correlated well with LVEF measured with CMR using either the ALEF method (Pearson correlation r = 0.94, P <0.01) or Simpson method (r = 0.92, P<0.01). It also correlated well with LVEF measured using 2D echo (r = 0.80, P < 0.01). Conclusion LVEF measurements by 64-row MDCT correlated well with LVEF measured by CMR and 2D echo. The correlation between 64-row MDCT and CMR was better than the correlation between 2D echo with CMR. Standard data set from a 64-row MDCT coronary study can be reliably used to calculate the LVEF. (J Geriatr Cardiol 2006;3(1): 2-8)
引用
收藏
页码:2 / 8
页数:7
相关论文
共 50 条
  • [1] Assessment of global and regional left ventricular function using 64-row multi detector computed tomography and 2D echocardiography: A comparison with cardiac magnetic resonance
    Rapaee, A.
    Liew, C. K.
    Chin, S. P.
    Ong, T. K.
    Chan, W. L.
    Ang, C. K.
    Seyfarth, M. T.
    Sim, K. H.
    [J]. EUROPEAN HEART JOURNAL, 2006, 27 : 423 - 423
  • [2] Comparison of multi-detector row computed tomography with echocardiography for assessment of left ventricular function in healthy dogs
    Henjes, Christiane R.
    Hungerbuehler, Stephan
    Bojarski, Iwona B.
    Nolte, Ingo
    Wefstaedt, Patrick
    [J]. AMERICAN JOURNAL OF VETERINARY RESEARCH, 2012, 73 (03) : 393 - 403
  • [3] Left ventricular functional analysis using 64-slice multi-detector row computed tomography: Comparison with echocardiography, cardiovascular magnetic resonance and left ventriculography
    Wu, Yen-Wen
    Tadamura, Eiji
    Kanao, Shotaro
    Yamamuro, Masaki
    Togashi, Kaori
    [J]. CIRCULATION, 2006, 114 (18) : 496 - 496
  • [4] What is the best contrast injection protocol for 64-row multi-detector cardiac computed tomography?
    Lu, Jin-guo
    Lv, Bin
    Chen, Xiong-biao
    Tang, Xiang
    Jiang, Shi-liang
    Dai, Ru-ping
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2010, 75 (02) : 159 - 165
  • [5] Normal reference range for left ventricular volumes and ejection fraction by 64 slice multi-detector computed tomography
    Abraham, A.
    Dennie, C.
    Ruddy, T. D.
    Beanlands, R. S.
    Chow, B. J.
    [J]. CANADIAN JOURNAL OF CARDIOLOGY, 2007, 23 : 72C - 72C
  • [6] Assessment of right ventricular function for patients with rheumatic mitral stenosis by 64-slice multi-detector row computed tomography: comparison with magnetic resonance imaging
    Zhang Xiao-chun
    Yang Zhi-gang
    Guo Yin-kun
    Zhang Rui-ming
    Wang Jian
    Zhou Dai-quan
    Cheng Lin
    Chen Lin
    [J]. CHINESE MEDICAL JOURNAL, 2012, 125 (08) : 1469 - 1474
  • [7] Four-dimensional evaluation of implanted mechanical valve with 64-row multi-detector computed tomography
    Numata, Satoshi
    Okada, Hiroki
    Kitahara, Hiroto
    Kawazoe, Kohei
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2007, 31 (05) : 934 - 934
  • [8] Multi-detector row cardiac computed tomography accurately quantifies right and left ventricular size and function compared with cardiac magnetic resonance
    Raman, SV
    Shah, M
    McCarthy, B
    Garcia, A
    Ferketich, AK
    [J]. AMERICAN HEART JOURNAL, 2006, 151 (03) : 736 - 744
  • [9] Usefulness of 64-Row Multi-Detector Computed Tomography for the Evaluation of Patients with Variant Angina
    Yamaji, Kyohei
    Arita, Takeshi
    Soga, Yoshimitsu
    Shirai, Shinichi
    Ando, Kenji
    Sakai, Koyu
    Iwabuchi, Masashi
    Yokoi, Hiroyoshi
    Yasumoto, Hitoshi
    Nosaka, Hideyuki
    Nobuyoshi, Masakiyo
    [J]. CIRCULATION, 2008, 118 (18) : S846 - S846
  • [10] Comparison of gated SPECT, echocardiography and cardiac magnetic resonance imaging for the assessment of left ventricular ejection fraction and volumes
    Demir, Hakan
    Tan, Yusuf Z.
    Kozdag, Guliz
    Isgoren, Serkan
    Anik, Yonca
    Ural, Dilek
    Demirci, Ali
    Berk, Fatma
    [J]. ANNALS OF SAUDI MEDICINE, 2008, 27 (06) : 415 - 420