Calibration of the DAMPE Plastic Scintillator Detector and its on-orbit performance

被引:0
|
作者
Meng Ding [1 ,2 ]
Ya-Peng Zhang [1 ]
Yong-Jie Zhang [1 ]
Yuan-Peng Wang [3 ,4 ]
Tie-Kuang Dong [3 ]
Antonio De Benedittis [5 ,6 ]
Paolo Bernardini [5 ,6 ]
Fang Fang [1 ]
Yao Li [1 ,2 ]
Jie Liu [1 ]
Peng-Xiong Ma [3 ,4 ]
Zhi-Yu Sun [1 ]
Valentina Gallo [7 ]
Stefania Vitillo [7 ]
Zhao-Min Wang [8 ,9 ]
Yu-Hong Yu [1 ]
Chuan Yue [3 ,4 ]
Qiang Yuan [3 ]
Yong Zhou [1 ,2 ]
Yun-Long Zhang [10 ]
机构
[1] Department of Modern Physics, University of Science and Technology of China
[2] Institute of Modern Physics, Chinese Academy of Sciences
[3] University of Chinese Academy of Sciences
[4] Key Laboratory of Dark Matter and Space Astronomy, Purple Mountain Observatory, Chinese Academy of Sciences
[5] School of Astronomy and Space Science, University of Science and Technology of China
[6] Istituto Nazionale di Fisica Nucleare (INFN) - Sezione di Lecce
[7] Dipartimento di Matematica e Fisica E.De Giorgi, Universit`a del Salento
[8] Department of Nuclear and Particle Physics, University of Geneva
[9] Gran Sasso Science Institute  9. INFN Laboratori Nazionali del Gran Sasso
基金
中国国家自然科学基金;
关键词
cosmic ray; instrumentation: DAMPE; charge measurement; plastic scintillator detector calibration;
D O I
暂无
中图分类号
V447.1 [];
学科分类号
08 ; 0825 ;
摘要
The DArk Matter Particle Explorer(DAMPE) is a space-borne apparatus for detecting the highenergy cosmic-ray-like electrons, γ-rays, protons and heavy ions. The Plastic Scintillator Detector(PSD)is the top-most sub-detector of the DAMPE. The PSD is designed to measure the charge of incident highenergy particles and it also serves as a veto detector for discriminating γ-rays from charged particles. In this paper, a PSD on-orbit calibration procedure is described, which includes the five steps of pedestal, dynode correlation, response to minimum-ionizing particles, light attenuation function and energy reconstruction.A method for reconstructing the charge of incident high energy cosmic-ray particles is introduced. The detection efficiency of each PSD strip is verified to be above 99.5%; the total efficiency of the PSD for charged particles is above 99.99%.
引用
收藏
页码:147 / 156
页数:10
相关论文
共 50 条
  • [1] Calibration of the DAMPE Plastic Scintillator Detector and its on-orbit performance
    Ding, Meng
    Zhang, Ya-Peng
    Zhang, Yong-Jie
    Wang, Yuan-Peng
    Dong, Tie-Kuang
    De Benedittis, Antonio
    Bernardini, Paolo
    Fang, Fang
    Li, Yao
    Liu, Jie
    Ma, Peng-Xiong
    Sun, Zhi-Yu
    Gallo, Valentina
    Vitillo, Stefania
    Wang, Zhao-Min
    Yu, Yu-Hong
    Yue, Chuan
    Yuan, Qiang
    Zhou, Yong
    Zhang, Yun-Long
    [J]. RESEARCH IN ASTRONOMY AND ASTROPHYSICS, 2019, 19 (03)
  • [2] The plastic scintillator detector for DAMPE
    Yu, Yuhong
    Sun, Zhiyu
    Su, Hong
    Yang, Yaqing
    Liu, Jie
    Kong, Jie
    Xiao, Guoqing
    Ma, Xinwen
    Zhou, Yong
    Zhao, Hongyun
    Mo, Dan
    Zhang, Yongjie
    Yang, Peng
    Chen, Junling
    Yang, Haibo
    Fang, Fang
    Zhang, Shengxia
    Yao, HuiJun
    Duan, Jinglai
    Niu, Xiaoyang
    Hu, Zhengguo
    Wang, Zhaomin
    Wang, Xiaohui
    Zhang, Jingzhe
    Liu, Wenqiang
    [J]. ASTROPARTICLE PHYSICS, 2017, 94 : 1 - 10
  • [3] Temperature dependence of the plastic scintillator detector for DAMPE
    王兆民
    余玉洪
    孙志宇
    岳珂
    闫铎
    张永杰
    周勇
    方芳
    黄文学
    陈俊岭
    [J]. Chinese Physics C, 2017, (01) : 143 - 148
  • [4] A method for aligning the plastic scintillator detector on DAMPE
    Peng-Xiong Ma
    Yong-Jie Zhang
    Ya-Peng Zhang
    Yao Li
    Jing-Jing Zang
    Xiang Li
    Tie-Kuang Dong
    Yi-Zhong Fan
    Shi-Jun Lei
    Jian Wu
    Yu-Hong Yu
    Qiang Yuan
    Chuan Yue
    Zhi-Yu Sun
    [J]. Research in Astronomy and Astrophysics, 2019, 19 (06) : 65 - 72
  • [5] A Method of Alignment for Plastic Scintillator Detector of DAMPE
    Ma, PengXiong
    [J]. 36TH INTERNATIONAL COSMIC RAY CONFERENCE, ICRC2019, 2021,
  • [6] Temperature dependence of the plastic scintillator detector for DAMPE
    Wang, Zhao-Min
    Yu, Yu-Hong
    Sun, Zhi-Yu
    Yue, Ke
    Yan, Duo
    Zhang, Yong-Jie
    Zhou, Yong
    Fang, Fang
    Huang, Wen-Xue
    Chen, Jun-Ling
    [J]. CHINESE PHYSICS C, 2017, 41 (01)
  • [7] A method for aligning the plastic scintillator detector on DAMPE
    Ma, Peng-Xiong
    Zhang, Yong-Jie
    Zhang, Ya-Peng
    Li, Yao
    Zang, Jing-Jing
    Li, Xiang
    Dong, Tie-Kuang
    Fan, Yi-Zhong
    Lei, Shi-Jun
    Wu, Jian
    Yu, Yu-Hong
    Yuan, Qiang
    Yue, Chuan
    Sun, Zhi-Yu
    [J]. RESEARCH IN ASTRONOMY AND ASTROPHYSICS, 2019, 19 (06)
  • [8] On-orbit calibration and long-term performance of the DAMPE trigger system
    Li, Wen-Hao
    Yue, Chuan
    Zhang, Yong-Qiang
    Guo, Jian-Hua
    Yuan, Qiang
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1069
  • [9] On-orbit performance of the DAMPE BGO calorimeter
    Wei, Yifeng
    Barbato, F. C. T.
    Casilli, E.
    de Palma, F.
    Marsella, G.
    [J]. 37TH INTERNATIONAL COSMIC RAY CONFERENCE, ICRC2021, 2022,
  • [10] Charge measurement of cosmic rays by Plastic Scintillator Detector of DAMPE
    Ma, Peng-Xiong
    Di Santo, M.
    Xu, Zhi-Hui
    Zhang, Yong-Jie
    [J]. 37TH INTERNATIONAL COSMIC RAY CONFERENCE, ICRC2021, 2022,