Combination of Toric and multifocal intraocular lens implantation in bilateral cataract patients with unilateral astigmatism

被引:0
|
作者
Jing-Li Liang [1 ]
Fang Tian [1 ]
Hong Zhang [1 ]
He Teng [1 ]
机构
[1] Tianjin Medical University Eye Hospital
关键词
Toric; multifocal; intraocular lens; binocular cataract; unilateral astigmatism;
D O I
暂无
中图分类号
R779.6 [眼外科手术学];
学科分类号
100212 ;
摘要
AIM: To assess the binocular visual function in bilateral cataract patients with unilateral astigmatism after combined implantations of Toric with multifocal intraocular lens(IOL), and to compare with that of Toric and monofocal IOL implantation.· METHODS: All the 30 patients with unilateral astigmatism suffered bilateral cataract were randomly divided into two groups: Toric plus multifocal IOL group and Toric plus monofocal IOL group. Uncorrected and corrected visual acuity at distance(5.0 m), intermediate distance(0.6 m), and near(0.33 m), contrast sensitivity,and stereopsis were assessed 6mo after surgery.Patients were also surveyed for visual disturbances and spectacle dependence.·RESULTS: Binocular uncorrected visual acuity(log MAR)of Toric/multifocal IOL eyes at distance, intermediate,near were 0.05±0.05, 0.24±0.10, and 0.14±0.06 respectively.The values of Toric plus monofocal IOL eyes were 0.06 ±0.07, 0.26±0.08, and 0.37 ±0.10 respectively. These values did not indicate significant differences between two groups with exception of near visual acuity. In the photopic condition(with or without glare), the contrast sensitivity of multifocal IOL eyes was significant lower than the monofocal IOL eyes in 18 cpd. In the mesopic condition, the contrast sensitivity of multifocal group was significant lower than monofocal group in 12 cpd, and in mesopic glare condition, this significant difference was found both in 6 cpd and 12 cpd. The stereopsis of Toric/multifocal IOL eyes decreased slightly(100 ±80 seconds of arc, t =2.222, P =0.136). Mean near vision for patient satisfaction was statistically significantly higher in Toric/multifocal IOL group patients versus than that in Toric/monofocal IOL group(80% vs 25.5%, P =0.000). Visual disturbance was not noticed in either group.·CONCLUSION: Although the combination of Toric and multifocal IOL implantation results in compromising stereoacuity, it can still provide patients with high levels of spectacle freedom and good overall binocular visual acuity.
引用
收藏
页码:1766 / 1771
页数:6
相关论文
共 50 条
  • [1] Combination of Toric and multifocal intraocular lens implantation in bilateral cataract patients with unilateral astigmatism
    Liang, Jing-Li
    Tian, Fang
    Zhang, Hong
    Teng, He
    [J]. INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2016, 9 (12) : 1766 - 1771
  • [2] Multifocal intraocular lens implantation in prepresbyopic patients with unilateral cataract
    Jacobi, PC
    Dietlein, TS
    Lüke, C
    Jacobi, FK
    [J]. OPHTHALMOLOGY, 2002, 109 (04) : 680 - 686
  • [3] TORIC INTRAOCULAR LENS IMPLANTATION FOR ASTIGMATISM CORRECTION IN CATARACT SURGERY
    Vickovic, Ivanka Petric
    Loncar, Valentina Lacmanovic
    Mandic, Zdravko
    Ivekovic, Renata
    Herman, Jelena Skunca
    Sesar, Antonio
    [J]. ACTA CLINICA CROATICA, 2012, 51 (02) : 293 - 297
  • [4] The Results of Phacoemulsification and Toric Intraocular Lens Implantation in Patients with High Astigmatism and Cataract
    Kilic, Ilkay
    Akova, Yonca Aydin
    Akman, Ahmet
    Egrilmez, Sait
    [J]. TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2012, 42 (02): : 116 - 119
  • [5] Toric Intraocular Lens Implantation for Correction of Astigmatism in Cataract Patients with Corneal Ectasia
    Parikakis, Efstratios A.
    Chatziralli, Irini P.
    Peponis, Vasileios G.
    David, Georgios
    Chalkiadakis, Spyridon
    Mitropoulos, Panagiotis G.
    [J]. CASE REPORTS IN OPHTHALMOLOGY, 2013, 4 (03): : 219 - 228
  • [6] Cataract surgery with toric intraocular lens implantation in patients with high corneal astigmatism
    Visser, Nienke
    Ruiz-Mesa, Ramon
    Pastor, Francisco
    Bauer, Noel J. C.
    Nuijts, Rudy M. M. A.
    Montes-Mico, Robert
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (08): : 1403 - 1410
  • [7] OUTCOMES OF CATARACT PATIENTS WITH ASTIGMATISM: IMPLANTATION OF TORIC VERSUS CONVENTIONAL MONOFOCAL INTRAOCULAR LENS
    Denevich, S.
    Lee, W. C.
    Waycaster, C.
    Pennie, S.
    Ganz, M.
    Pashos, C. L.
    [J]. VALUE IN HEALTH, 2009, 12 (03) : A77 - A77
  • [8] Comparison of trifocal toric and bifocal toric intraocular lens implantation in patients with cataract and high corneal astigmatism
    Gencer, Merve Bozkurt
    Basmak, Hikmet
    Yasar, Erdogan
    Onal, Ozkan
    [J]. INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2021, 14 (12) : 1876 - 1881
  • [9] Comparison of trifocal toric and bifocal toric intraocular lens implantation in patients with cataract and high corneal astigmatism
    Merve Bozkurt Gencer
    Hikmet Basmak
    Erdogan Yasar
    Ozkan Onal
    [J]. International Journal of Ophthalmology, 2021, 14 (12) : 1876 - 1881
  • [10] Astigmatism correction with a foldable toric intraocular lens in cataract patients
    Ruhswurm, I
    Scholz, U
    Zehetmayer, M
    Hanselmayer, G
    Vass, C
    Skorpik, C
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (07): : 1022 - 1027