Accuracy of ultrasonography in diagnosis of fetal central nervous system malformation

被引:0
|
作者
Bo Pang [1 ]
Jing-Jing Pan [2 ]
Qin Li [3 ]
Xia Zhang [1 ]
机构
[1] Department of Ultrasound, The First Affiliated Hospital of Wannan Medical College
[2] Department of Neurosurgery, The Second People's Hospital of Wuhu
[3] Department of Gynaecology and Obstetrics, The First Affiliated Hospital of Wannan Medical College
关键词
D O I
暂无
中图分类号
R445.1 [超声波诊断]; R714.53 [胎儿畸形的产前诊断];
学科分类号
100207 ; 100211 ;
摘要
BACKGROUND Prenatal examination is an important measure for the screening and diagnosis of fetal malformations.AIM To investigate the accuracy of ultrasonography in the diagnosis of fetal central nervous system(CNS) malformations.METHODS One hundred and thirteen pregnant women suspected of having fetal CNS malformations were examined at our hospital from December 2018 to October 2020 using two-dimensional ultrasonography and three-dimensional ultrasonography, respectively.RESULTS According to the pathological results, there were 79 cases of CNS malformations and 34 cases of non-CNS malformations among the 113 pregnant women suspected of having fetal CNS malformation. Fifty-one cases of CNS malformation and 26 cases of non-CNS malformation were detected by two-dimensional ultrasonography, and 73 cases of CNS malformation and 30 cases of non-CNS malformation were detected by three-dimensional ultrasonography. The diagnostic sensitivity(92.41%) and accuracy(91.15%) of three-dimensional ultrasonography were higher than those of two-dimensional ultrasonography(64.56% and 68.14%, respectively)(P = 0.000). The specificity of three-dimensional ultrasonography(88.24%) was higher than that of two-dimensional ultrasonography(76.47%); however, the difference was not significant(P = 0.203).CONCLUSION Three-dimensional ultrasonography has high application value in the diagnosis of fetal CNS malformations. In addition, the image quality is clear, and the diagnostic sensitivity and accuracy are high.
引用
收藏
页码:8027 / 8034
页数:8
相关论文
共 50 条
  • [1] Accuracy of ultrasonography in diagnosis of fetal central nervous system malformation
    Pang, Bo
    Pan, Jing-Jing
    Li, Qin
    Zhang, Xia
    WORLD JOURNAL OF CLINICAL CASES, 2021, 9 (27) : 8027 - 8034
  • [2] Fetal central nervous system anomalies: comparison of magnetic resonance imaging and ultrasonography for diagnosis
    WANG Guangbin SHAN Ruiqin MA Yuxiang SHI Hao CHEN Liguang LIU Wen QIU Xiuling WEI Yulong GUO Li QU Lei and LI Huihua Shandong Medical Imaging Research Institute Jinan China Jinan Maternity and Child Care Hospital Jinan China
    Chinese Medical Journal, 2006, (15) : 1272 - 1277
  • [3] Fetal central nervous system anomalies: Comparison of magnetic resonance imaging and ultrasonography for diagnosis
    Wang Guang-bin
    Shan Rui-qin
    Ma Yu-xiang
    Shi Hao
    Chen Li-guang
    Liu Wen
    Qiu Xiu-ling
    Wei Yu-long
    Guo Li
    Qu Lei
    Li Hui-hua
    CHINESE MEDICAL JOURNAL, 2006, 119 (15) : 1272 - 1277
  • [5] EARLY DIAGNOSIS OF FETAL MALFORMATION BY ULTRASONOGRAPHY
    BERNASCHEK, G
    DADAK, C
    KRATOCHWIL, A
    GEBURTSHILFE UND FRAUENHEILKUNDE, 1980, 40 (10) : 868 - 875
  • [6] Prediction and Value of Ultrasound Image in Diagnosis of Fetal Central Nervous System Malformation under Deep Learning Algorithm
    Zhou, Yuehong
    SCIENTIFIC PROGRAMMING, 2021, 2021
  • [7] Malformation and Tumor of the Central Nervous System and
    Chasan, Beatrice
    SCHWEIZER ARCHIV FUR NEUROLOGIE UND PSYCHIATRIE, 1931, 27 (01): : 64 - 107
  • [8] Vascular Malformation of the Central Nervous System
    Grasso, Giovanni
    WORLD NEUROSURGERY, 2022, 159 : 248 - 249
  • [9] Fetal MRI vs. fetal ultrasound in the diagnosis of pathologies of the central nervous system
    Pimentel, Ines
    Costa, Joao
    Tavares, Oscar
    EUROPEAN JOURNAL OF PUBLIC HEALTH, 2021, 31
  • [10] MRI combined ultrasound in diagnosis of fetal central nervous system malformations
    Fan, Lixin
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2020, 126 : 143 - 143