Sensitive determination of buformin using poly-aminobenzoic acid modified glassy carbon electrode

被引:1
|
作者
Gui-Ying Jin [1 ]
Hui Li [1 ]
Wan-Bang Xu [1 ]
机构
[1] Guangdong Institute for Drug Control
关键词
Chemically modified electrode; Aminobenzoic acid; Buformin;
D O I
暂无
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Glassy carbon electrode, which is used to electrochemically determine the content of buformin, is modified with an electropolymerized film of p-aminobenzoic acid in pH 7.0 acetate buffer solution (ABS). The polymer showed an excellent electrocatalytic activity for the reduction of buformin. In pH 7.0 ABS, the cathodic peak current increased linearly over three concentration intervals of buformin, and the detection limit (S/N=3) was 2.0×10-9 g/mL. The method was successfully applied to directly determine buformin in tablets with standard addition recoveries of 95.8-102.5%. The proposed method is simple, cheap and highly efficient.
引用
收藏
页码:458 / 461
页数:4
相关论文
共 50 条
  • [1] Simultaneous determination of hydroquinone and catechol Using poly(p-aminobenzoic acid) modified glassy carbon electrode
    Yang, Ping
    Zhu, Qiyong
    Chen, Yonghong
    Wang, Fengwu
    Journal of Applied Polymer Science, 2009, 113 (05): : 2881 - 2886
  • [2] Simultaneous Determination of Hydroquinone and Catechol Using Poly(p-aminobenzoic acid) Modified Glassy Carbon Electrode
    Yang, Ping
    Zhu, Qiyong
    Chen, Yonghong
    Wang, Fengwu
    JOURNAL OF APPLIED POLYMER SCIENCE, 2009, 113 (05) : 2881 - 2886
  • [3] Sensitive determination of adenine on poly(amidosulfonic acid)-modified glassy carbon electrode
    Zhang, Rui
    Jin, Gendi
    Hu, Xiaoya
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2009, 13 (10) : 1545 - 1552
  • [4] Sensitive determination of adenine on poly(amidosulfonic acid)-modified glassy carbon electrode
    Rui Zhang
    Gendi Jin
    Xiaoya Hu
    Journal of Solid State Electrochemistry, 2009, 13 : 1545 - 1552
  • [5] Sensitive electrochemical determination of Sudan II in food samples using a poly(aminosulfonic acid) modified glassy carbon electrode
    Xinying Ma
    Mingyong Chao
    Russian Journal of Electrochemistry, 2013, 49 : 1057 - 1064
  • [6] Sensitive electrochemical determination of Sudan II in food samples using a poly(aminosulfonic acid) modified glassy carbon electrode
    Ma, Xinying
    Chao, Mingyong
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2013, 49 (11) : 1057 - 1064
  • [7] Determination of Acetaminophen in the Presence of Ascorbic Acid Using a Glassy Carbon Electrode Modified with Poly(Caffeic acid)
    Filik, Hayati
    Avan, Asiye Aslihan
    Aydar, Sevda
    Cetintas, Gamze
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (01): : 148 - 160
  • [8] Determination of dopamine in the presence of ascorbic acid using poly(hippuric acid) modified glassy carbon electrode
    Zhao, H
    Zhang, YH
    Yuan, ZB
    ELECTROANALYSIS, 2002, 14 (14) : 1031 - 1034
  • [9] Determination of Dopamine in the Presence of Ascorbic Acid Using a Poly(Amidosulfonic Acid) Modified Glassy Carbon Electrode
    Yuzhong Zhang
    Guiying Jin
    Zhousheng Yang
    Hong Zhao
    Microchimica Acta, 2004, 147 : 225 - 230
  • [10] Determination of dopamine in the presence of ascorbic acid using a poly(amidosulfonic acid) modified glassy carbon electrode
    Zhang, YZ
    Jin, GY
    Yang, ZS
    Zhao, H
    MICROCHIMICA ACTA, 2004, 147 (04) : 225 - 230