Purpose:To analyze the sensitivity and specificity of X-ray, B-ultrasound, and CT scan in diagnosing ocular foreign bodies, and to compare the accuracy of these three imaging tools in locating these foreign bodies. Methods:A retrospective review was conducted of radio graphic and clinical eye examination data from 62 patients (66 eyes),suspected of having ocular foreign bodies at time of first presentation to the Zhongshan Ophthalmic Center (Guangzhou, China) between August 2007 and October 2011. The sensitivity and specificity of X-ray, B-ultrasound and CT scan in the diagnosis of ocular foreign bodies were investigated and their accuracy in locating these foreign bodies was compared. Results: A total of 75.8% (n=47) subjects had ocular foreign bodies; 66% of these were metallic. Patients with intraocular, eye wall,and extraocular foreign bodies accounted for 46, 28, and 26% of the total, respectively. The sensitivities of X-ray,CT scan,and B-ultrasound in the diagnosis of ocular foreign bodies were 58.3%, 61.7%, and 75%, the specificityies were 63.3%, 100%, and 87.5%, and the accuracy in locating foreign bodies was 73.4%, 94.7%, and 86.5%, respectively. The properties of foreign bodies affected the diagnosistic accuracy of X-ray,but exerted little impact upon B-ultrasound and CT scan. Conclusion:A fairly high incidence of ocular foreign bodies was noted in patients suspected with ocular foreign bodies at their first presentations.X-ray combined with CT scan or X-ray in combination with B-ultrasound showed a relatively high sensitivity and specificity in diagnosing ocular foreign bodies. CT scan had the highest accuracy in locating ocular foreignbodies. (Eye Science 2013; 28:11-14)
引用
收藏
页码:11 / 14
页数:4
相关论文
共 5 条
  • [1] X线、B超、CT和MRI在眼内异物诊断中应用价值的评估 [J]. 张春杰.&nbsp&nbsp眼外伤职业眼病杂志(附眼科手术). 2009(08)
  • [2] 多种影像方法联合诊断眼内异物及其并发症
    朱豫
    张效房
    盛艳娟
    [J]. 中华眼科杂志, 2003, (09) : 11 - 14
  • [3] INTRAOCULAR FOREIGN-BODY MISSED BY COMPUTED-TOMOGRAPHY
    BARNES, E
    GRIFFITHS, M
    ELLIOTT, A
    [J]. BRITISH MEDICAL JOURNAL, 1993, 306 (6891): : 1542 - 1542
  • [4] Visual outcome following intraocular foreign bodies:a retrospective review of 5-year clinical experience .2 Bai HQ,Yao L,Meng XX,Wng YX,et al. Eur J Ophthalmol . 2011
  • [5] Diagnostic valueof clinical examination and radiographic imaging in i-dentification of intraocular foreign bodies in open globeinjury .2 Patel SN,Langer PD,Zarbin MA,et al. Eur J Ophthalmol . 2012