Effect of persistent high intraocular pressure on microstructure and hydraulic permeability of trabecular meshwork

被引:0
|
作者
梅曦 [1 ,2 ]
任琳 [1 ,2 ]
许强 [3 ]
郑炜 [3 ]
刘志成 [1 ,2 ]
机构
[1] School of Biomedical Engineering, Capital Medical University
[2] Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application
[3] Shenzhen Key Laboratory for Molecular Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences
基金
中国国家自然科学基金;
关键词
trabecular meshwork; hydraulic permeability; intraocular pressure; glaucoma;
D O I
暂无
中图分类号
R775 [眼压与青光眼];
学科分类号
100212 ;
摘要
As the aqueous humor leaves the eye, it first passes through the trabecular meshwork(TM). Increased flow resistance in this region causes elevation of intraocular pressure(IOP), which leads to the occurrence of glaucoma. To quantitatively evaluate the effect of high IOP on the configuration and hydraulic permeability of the TM, second harmonic generation(SHG) microscopy was used to image the microstructures of the TM and adjacent tissues in control(normal) and high IOP conditions. Enucleated rabbit eyes were perfused at a pressure of 60 mm Hg to achieve the high IOP. Through the anterior chamber of the eye, in situ images were obtained from different depths beneath the surface of the TM. Porosity and specific surface area of the TM in control and high IOP conditions were then calculated to estimate the effect of the high pressure on the permeability of tissue in different depths. We further photographed the histological sections of the TM and compared the in situ images. The following results were obtained in the control condition, where the region of depth was less than55 μm with crossed branching beams and large pores in the superficial TM. The deeper meshwork is a silk-like tissue with abundant fluorescence separating the small size of pores. The total thickness of pathway tissues composed of TM and juxtacanalicular(JCT) is more than 100 μm. After putting a high pressure on the inner wall of the eye, the TM region progressively collapses and decreases to be less than 40 μm. Fibers of the TM became dense, and the porosity at 34 μm in the high IOP condition is comparable to that at 105 μm in the control condition. As a consequent result, the permeability of the superficial TM decreases rapidly from 120 μm2to 49.6 μm2and that of deeper TM decreases from 1.66 μm2to0.57 μm2. Heterogeneity reflected by descent in permeability reduces from 12.4 μm of the control condition to 3.74 μm of the high IOP condition. The persistently high IOP makes the TM region collapse from its normal state, in which the collagen fibers of the TM are arranged in regular to maintain the physiological permeability of the outflow pathway. In the scope of pathologically high IOP, the microstructure of the TM is sensitive to pressure and hydraulic permeability can be significantly affected by IOP.
引用
收藏
页码:610 / 617
页数:8
相关论文
共 50 条
  • [1] Effect of persistent high intraocular pressure on microstructure and hydraulic permeability of trabecular meshwork
    Xi, Mei
    Lin, Ren
    Qiang, Xu
    Wei, Zheng
    Liu Zhi-Cheng
    CHINESE PHYSICS B, 2015, 24 (05)
  • [2] The impact of trabecular meshwork permeability on circadian rhythms of intraocular pressure
    Sacco, Riccardo
    Chiaravalli, Greta
    Guidoboni, Giovanna
    Layton, Anita
    Verticchio, Alice
    Siesky, Brent A.
    Kellner, Rebecca
    Ritzer, Lukas
    Harris, Alon
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [3] Pressure effect on hydraulic conductivity of human trabecular meshwork cells
    Grzybowski, DM
    Roberts, CJ
    Rivera, BK
    Weber, PA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [4] Estrogen signaling, trabecular meshwork, and intraocular pressure regulation
    Liu, Yutao
    Youngblood, Hannah
    Cai, Jingwen
    Sun, Jason
    Yu, Hongfang
    Schoenlein, Patricia
    Xu, Hongyan
    Smith, Sylvia B.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [5] Stem Cells in the Trabecular Meshwork for Regulating Intraocular Pressure
    Yun, Hongmin
    Zhou, Yi
    Wills, Andrew
    Du, Yiqin
    JOURNAL OF OCULAR PHARMACOLOGY AND THERAPEUTICS, 2016, 32 (05) : 253 - 260
  • [6] Gene expression in the trabecular meshwork and the influence of intraocular pressure
    Borrás, T
    PROGRESS IN RETINAL AND EYE RESEARCH, 2003, 22 (04) : 435 - 463
  • [7] Effect of topical application of adrenaline on Schlemm canal, trabecular meshwork and intraocular pressure
    Ye, Meng
    Chen, Zhiqi
    Li, Mu
    Chen, Wei
    Zhang, Hong
    Wang, Junming
    MEDICINE, 2019, 98 (22)
  • [8] Understanding trabecular meshwork physiology: A key to the control of intraocular pressure?
    Llobet, A
    Gasull, X
    Gual, A
    NEWS IN PHYSIOLOGICAL SCIENCES, 2003, 18 : 205 - 209
  • [9] Fluctuations in Intraocular Pressure Increase the Trabecular Meshwork Extracellular Matrix
    Zou, Huan
    Yuan, Rongdi
    Zheng, Qijun
    Huo, Yan
    Lang, Min
    Ji, Shuxing
    Zheng, Zheng
    Ye, Jian
    CELLULAR PHYSIOLOGY AND BIOCHEMISTRY, 2014, 33 (04) : 1215 - 1224
  • [10] Effect of Latanoprostene Bunod on the Permeability of Trabecular Meshwork Cells
    Park, Hyeong Seok
    Kim, Jae Woo
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2024, 65 (02): : 139 - 144